Loading...
HomeMy WebLinkAboutO-1708ORDINANCE NO. 1708 AN ORDINANCE AMENDING ORDINANCE NO. 1253 KNOWN AS THE ZO ING ORDINANCE AND AME DING ORDINANCE 0.1664 BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY OF FAIRHOPE, ALABAMA as follows : The ordinance known as the Zoning Ordinance (No. 1253), adopted 27 June 2005, together with the Zoning Map of the City ofFairhope, be and the same hereby is changed and altered in respect to that certain property described below : After the appropriate public notice and hearing of the Planning Commission of the City of Fairhope, Alabama has forwarded a favorable recommendation, The property ofGayfer Village Partners, Inc . generally located on the west side of State Hwy. 181 between Gayfer Road and Fairhope A venue , Fairhope, Alabama. KLUMPP PUD AMENDME T PPIN #: 24160, 236701 and 316793 Legal Description: (Case number ZC 20.10) COMMENCE AT A RAILROAD SPIKE AT THE NORTHEAST COR ER OF SECTIO 15 , TOWNSHIP 6 SOUTH, RA GE 2 EAST, BALDWIN COUNTY , ALABAMA; RU THE CEWEST,ALO GTHE ORTHLINEOFSAIDSECTIO 151320.55FEETTOA POI T ; RUN THE CE SOUTH 00-22-18 WEST, 29.73 FEET TO A CAPPED REBAR MARKER ON THE SOUTH RIGHT-OF-WAY LINE OF GA YFER A VENUE FOR THE POI T OF BEG! ING OF THE PROPERTY HEREI DESCRIBED , SAID POI T BEI GTHE ORTHEASTCORNEROF "WHITEGROVESUBDIVISIO , UNITTWO" AS RECORDED O SLIDE 1344-B IN THE BALDWIN COUNTY PRO BA TE RECORDS , CONTINUE THENCE SOUTH 00-22-18 WEST, ALONG THE EAST LI E OF SAID SUBDIVISION, 1298.08 FEET TO A CAPPED REBAR MARKER AT THE SOUTHEAST CORNER OF SAID SUBDIVISION ; RUN THENCE SOUTH 00-56-09 WEST, 1297 .18 FEET TO A CAPPED REBAR MARKER O THE NORTH RIGHT-OF-WAY LINE OF FAIRHOPE A VE UE ; RUN THE CE SOUTH 89-55-36 EAST, ALO G SAID RIGHT- OF-W A Y LINE, 1178 .82 FEET TO A CAPPED REBAR MARKER; RUN THE CE ORTH 45-24-21 EAST , 132 .28 FEET TO A CAPPED REBAR MARKER ON THE WEST RIGHT-OF-WAYLI EOFCOU TYROAD27;RU THE CENORTH00-44-18EAST, ALO G SAID WEST RIGHT OF WAY LI E , 229.22 FEET TO A CAPPED REBAR MARKER; THENCE CONTINUE NORTH 00-44-18 EAST, ALONG SAID RIGHT-OF- WAY, 107.86 FEET TO A CAPPED REBAR MARKER; THENCE RUN NORTH 04-44-33 EAST, ALONG SAID RIGHT-OF-WAY , 100.24FEETTO A CAPPED REBAR MARKER; THE CERU ORTH00-44-18EAST,ALO GSAIDRIGHT-OF-WAY ,433.00FEET TO A CAPPED REBAR MARKER ; RU THE CE ORTH 00-44-18 EAST, ALO G SAID RIGHT-OF-WAY LINE , 1562.96FEETTOACAPPEDREBARMARKERO THE SOUTH RIGHT-OF-WAY LINE OFGAYFERAVENUE; RUN THENCE SOUTH 89 -57 -26 WEST, ALONG SAID RIGHT-OF-WAY LI E , 1282 .66 FEET TO THE POI T OF BEGIN I G ; CO TAI I G 75 .93 ACRES , MORE OR LESS. 1. That, attached as "Exhibit A" is an approved site plan. The property must develop in substantial conformance with the approved site plan and supporting documents. Any substantial deviation from the attached site plan , as determined by the Director of Planning, will require re-approval by the Planning Commission and the City Council of the City of Fairhope, Alabama, as a PUD amendment. Ordinance No. 1708 Page -2- 2. That, the following development regulations shall govern: A master drainage plan shall be required for the entire site and included with the initial subdivision application creating units 1-3 . City of Fairhope Site Plan Review (Zoning Ordinance) shall be mandatory for each lot within units 1-3 . City of Fairhope Subdivision Regulations (including Multiple Occupancy Project provisions as applicable) shall be required for the creation of all lots and units within the Klumpp PUD . In addition to the greenspace buffer on Fairhope Avenue and Gayfer Road, a 20' greenspace and tree preservation strip shall be provided along State Highway 181. Construction of sidewalks shall be done at the time of development of the internal roadways . A 45 ' combined setback and buffer shall be maintained along the western property line of the development. The western most 1 O' shall meet the Section 20.5-4 of the City of Fairhope Tree Ordinance. UNIT 1: Lots: There shall be a maximum of 12 commercial lots. Site Plan Review: A stand-alone site plan review shall be required for each lot. Use: Commercial uses shall be restricted to the B-2 requirements in the Fairhope Zoning Ordinance. Dimension Standards: Setbacks , building height, and lot coverage shall be per the B-2 requirements. Drainage and Detention: Each lot shall provide its own stormwater control and detention and shall meet the Storm water Standards requirements in the Fairhope Subdivision Regulations. Parking: Parking shall be located to the side or rear of the buildings. Parking shall meet the requirements of the Fairhope Zoning Ordinance. UNIT 2: Lots: There shall be one lot. Units: The number of units shall not exceed 233 units. Site Plan Review: A stand-alone site plan review shall be required. Multiple Occupancy Project Review : A multiple occupancy project review shall be required . Use: The use of Unit 2 shall be restricted to the R-3 requirements in the Fairhope Zoning Ordinance. Dimension Standards: The setbacks, building height, and lot coverage shall be per the R-3 requirement. The R-3 minimum lot width shall not apply , and the lot dimension shall be as shown on the site plan. Drainage and Detention: Drainage and detention shall meet the Storm water Standards requirements in the Fairhope Subdi v ision Regulations. Ordinance No . 1708 Page -3 - Parking: Parking shall meet the requirements of the Fairhope Zoning Ordinance. Greenspace: Twenty percent (20 %) greenspace shall be required as shown on the site plan . Provided retention/detention shall not encroach into required greenspace other than those methods approved within the City of Fairhope Subdivision Regulations and/or as approved during MOP/Site Plan Review. U IT 3: Lots: There shall be one lot. Site Plan Review: A stand-alone site plan review shall be required . Use: The uses of Unit 3 shall be restricted to convalescent, nursing, or assisted living . Dimension Standards: The setbacks, building height, and lot coverage shall be per the R-3 requirement. The R-3 minimum lot width shall not apply, and the lot dimen si on shall be as shown on the site plan. Drainage and Detention: Drainage and detention shall meet the Storm water Standards requirements in the Fairhope Subdivision Regul atio ns. The Planned Unit Development (PUD) known as Klum pp PUD is hereby amended. This property shall hereafter be lawful to construct on such property any structures permitted by Ordin ance o. 1253 and to use said premises for any use permitted or building sought to be erected on said property shall be in compliance with the building laws of the City of Fairhope and that any structure shall be approved by the Building Official of the City of Fairhope and that any structure be erected only in compliance with such laws , including the requirements of Ordinance No. 1253 . Severability Clause -if any part, section or ubdivision of this ordinance shall be held unconstitutional or invalid for any reason , such holding shall not be construed to invalidate or impair the remainder of this ordinance, which shall continue in full force and effect notwithstanding such holding . Effective Date -Thi ordinance shall take effect immediately upon its due adoption and publication as required by law. Adopted and approved this 26th day of April , 2021. Attest: Adopted and approved this 26th da G 1 oc,,J:rW • tHHT'W ' 7 ,---~ ~ouf. .. OK~"'i">C>"iu~ftq I UNIT2 41 .03 AC .• i: I ~ ~ -"-ill p ! l 2 lrl d Q ! ~ ~ l~T 3 11,AC ~ ___ I f I ; lJNIT 3 co "' 0 10.63 AC.• . ~ "' lii u 0 ... ::I: w, 0 E u . a: g • ., ; u ;f_ ~ I .. &d o' ;._ !U 0 ::I: <, \ "-· ___ __,_ ___ _ ~ I ' ; "onn,•l1".11 "W~ " I N ono,· l <UOIW 1 UNIT 1 i: 19.06AC.• • ;1 --,---- J ~ § 1:~ ,., it l •IAC i i ! ; ~ 100 0 100 200 z j ... ~ 0 0 ,-- "' i qi ... ... :i ,ij ,--_ ... .. C () > 0 0 .. ~ 10 5'(..-..) SIOEWAl.1< LOO.TEO IN 8tJFFER I SETBACK -'REA WESTERN UOST 10'W!L.L MEET SEC1lON 20~4 0¥ CI TY OF FAIRHOPE mf.E OAOINANCE 1.ANOSCAPE AAEAS . TYP. WITH CONNECTI~ TR.AIL -\ ~, .. r: r s-ch+-Nl()~ 4N09f'E ,o, 1.&lAC, < l -.,\ __ ,.. -,.. ,_ ~ 1 :-._--~~-~WAV'~i,_-_-_ -~ • UNIT2·!NTERNAL.STREETS SKAI.L PROVIO£ 5' (nw,.J 5t0EWALKS Al.ONG TH£ Bl.OCK PERtMETER ANO STREEr TREES 1N 6' PL...t.HTING STRIP A.T 61).80' 0 C. STREET TAfES SHALL BE SELECTED FROM SECTl()N 20 ~13 {OVERlA.Y TREES) OF CI TY OF FAIRHOPE TREE OR01NANCE (SPACING ADJUSTED FOR ORlVEWA.YS ANO VTIUTIES.J _, lJNIT J: fAJRHOf'f AVf HIGHWAY 181 ANQ CA,Yf'ER A0M) FRQHTAGES SHALL PROVIDE 5' [mill.) SIOEWA.lK ANO STREET TREE INS" P\..A.NTING STRIP TREES PROVlOEO A.T 45'0.C. STREET TREES Sl'W.L 8E SELECTfO FROM SECTION 20 ~13 (OVERLAY TREES) OF CITY OF FAIRHOPE TREE OA:OINAHCE !SPACING AO.A.ISTEO FOR OAIVEWAYS ANO UTILITIES I ,_ - lJNrT 2· INTERNAi. SIQEWA1,K5 FINAi. CROSSING LOCATIONS TO 8E COORDINATE O~NG FINAL St TE PERMITTING At.L SIDEWALKS TO 8E s· MlN GENEAAt.L Y AS SHOWN TO PROVIDE INTE~NNECTION ___ BETWEEN ANO ACCESS TO UNITS \AND J IJ!:!!11 SMAU PA0\110E A MtNIUUM OF J SDEWALX CONNECTIONS WITH ONE CONNECTING TO TI1E SIDEWALK FRONTING GA.YFE.R RO ANO ANOTI-ER CONNECTWG THE SIOEWALX ON THE EASTERN f:OGEOFUNlll. UNIT 3 J 0.83 AC .t l-AHOSCA.PE AAEA.S . fyp WITH CONNECTING T'RA.IL UNIT I ALL LQTS A.~0 CQMBINEO LOTS SHAU PRO\IOE PARKING TO SIDE OR REAR ~ 100 0 100 ~ 5·(mo.J SOEWALX LOO.TtO IN BUfFER I SETBACK AREA ,. "' w .. ~ :rl 0 z j L .. t: "' .. .. ~ .. > 0 0 T""""' l ql ,ii N " .. c( u -0 "' G PROPERTY DESCRIPTION STATE OF A1.ABAMA COUNTY Of BALDWIN COMMENCE AT A RAILROAD SPIKE A 1 THE NORTHEAST CORNER OF SECTION 15, TOWNSHIP 6 SOUTH, RANGE 2 EAST, BALDWIN COUNTY, A!.ABAMA: RUN THENCE WEST, ALONG THE NORTH LINE Of SAID SECTtON 15 1320.5!i FEET TO A POINT; RUN THENCE SOUTH 00-22-18 WEST, 29.73 FEET TO A CAPPED REBAR MARKER ON THE SOUTH RIGHT-OF-WAY LI NE OF GAYFER AVENUE FOR THE PO INT Of BEGINNING OF THE PROPERTY HEREI N DESCRIBED, SAID POINT BEING THE NORTHEAST CORNER OF "WHITE GROVE SUBDIVISION, UNIT TWO' AS RECORDED ON SllOE 1 34◄ -8 IN THE BAl..DWIN COUNTY PROBATE RECORDS . CONTINUE THENCE SOUTH 00-22-1 8 WEST . ALONG THE EAST LINE OF SAID SUBDI\IISION , 1298 06 FEET TO A CAPPED REBAR MARKER AT THE SOUTHEAS T CORNER OF SAID SUBDIVISION, RUN THENCE SOUTH 00-56-09WEST, 1297.18 FEET TOA CAPPED REBAR MARKER ON THE NORTH RJGHT - OF-WAY UNE OF FAIRHOPE AVENUE; RUN THENCE SOUTH 89-55-36 EAST, ALONG SAID RIGHT-OF-WAY UNE. 1178.82 FEET TO A CAPPED REBAR MARKER, RUN THENCE NORTH <lS-24-21 EAST. 132.28 FEET TO A CAPPED REBAR MARKER ON THE wes- RIGHT-Of-WAY LINE Of COUNTY ROAD 27, RUN THENCE NORTH 00--4'-18 EAST, ALONG SAIOWESTRIGHT-OF-WAYUNE, 229 22 FEET TOACN'PEO REBAR MARKER. THENCE CONTIM.JE NORTH 00-44-18 EAST, ALONG SAID RtGHT-OF-WAY, 107 86 FEET TO A CAPPED REBAR MARKER; THENCE RUN NORTH 04~4-33 EAST, ALONG SAID RIGHT-OF-WAY. 100.2-4 FEET TO A CAPPED REBAR MARKER, THENCE RUN NORTH 00- 44--18 EAST, Al.ONG SAID RIGHT-OF-WAY, 433.00 FEET TO A CAPPED REBAR MARKER, RUN THENCE NORTH 00-4'·1 8 EAST, ALONG SAID RIGHT-OF-WAY LINE, 1562.96 FEET TO A CAPPED REBAR MARKER ON THE SOUTH RIGHT-OF-WAY LI NE OF GAYFER AVENUE: RUN THENCE SOUTH 89-57-26WEST , ALONG SAID RIGHT-OF-WAY LINE 1282.66 FEET TO THE POINT Of BEGINNING· CONT A!NING 75.93 ACRES, MORE 0~ LESS. ~.!!! 1 °'"'""I ' ut,lo1yand~tnanu~11W11l5 wtlbep,o;idc,(l,.ndrttordcd.s n«~Urydunn&!>Jtepl•"""dsubdPV1110n•PPfOv,1I 1 heh lot ofuchun11 rnim prO\f!Mand rruo111t4'1n ~itrvedr,1nqe lor4'djacenl pro~"'1o lh4'1 mr, be disch4'rg,ng OfllO II l Sadr,r,.,llts (m,n S' Wldel will be provided along both ,u~ ol ,~e,y p,.,bhc. ~ttfft wllhln thePU0 4'1thetimelhestree<s are const ruCled 4 In •11..-npt 10 Khoew a cohtsrff th4'~ctl!'I' ol r~tl4'1 developml!flt w1 Unit 1, fronts old 1l!Slde-ntl1I butld1111unils w1thtn Unit 1 sh•Hf•II "'ilh in in , 10' m111 ind I <la'"'''"'""""' buoldlo tone from the1-lrfft, with IM uc~oon of btnldonp 1mp.1e1ed bot uul.ty lout ions. h1hl111c. or bu,ld,np louted •Ion& Lorne~ or cur""" In the il rff'I., whoch <:Ht! ll•es. bui&d,n1~ ~v ~••Y from lhl'I bu,ld 10 ,one ~ In •tt-,npttoKhie-;,e •cohbl"leCh4"tKht< ofdt-vW!)fT14'11tlnUnll 1 •nd1; All bu11d1n1 fK.tM ,n,te,11k lhal1 be constrocttd of •ke tNll!ri.11$ set III prl!(;~nl by the h i \II.I' pun ~pmenl submitt,1 '!, 1 Subsequtnl tiu,ldlnp m,y varv ,n mlltn•I b¥ provldon& 1ru1e, or equ4"1 qu4"ht)loflK4'dem4'1tri4"11nddt51gnnd.s10P<ovitdb¥1hePl•nn1111 Commisslon1ndC11ycounc,1 6 Sidewalks "'ithln .. 11 Unit 1, Unit 1, a nd Unit l lotswill bede.'llnitd •nd ~O.,~l•UCll!d ,n .. c.c;ordJll(tW,th lheS1ttPl.ln•pp,roYtdfo1t•chlol 7 All.,_ ,nd i.ndsupe nwtenal will be provided H ltst@od m lool l.lndl.c•P" ordtn4'11Cl!'S un~ oth-~ coordin1t@od wnh !ht c11v urb.ln for Miry or arbor~t I ,... 1- L...:...] .. TYPE "A" IHI c.:::::::J rJ~-~tJ TYPE "B" _" .... =lJ TYPE "C" TYPI C AL ROAD SECT ION S S-2 1-bll~andC,QM8'1,1Cte(1,n B ~.-.rtunool!N ~ll"l!hlheSfom,w111er&anoaraso1 1-r-1o1 Faort,ooeZ~ INF~SulldM-,R•g,,.1hOM />\JOJ Ordintnc:e R•l 1::;r,q bl!~ anod ~ on 8 C 5" P,r;ong al 11'11!! ao::ot~WlllllhtSIQlfflWll'ter .stanoun:i.ol (-T-2ol hlfhopeZo,w,g !t!tF'~SubOMIIOIIR9{11Ji..on. Pl.JO/ Or- 1-De~-,IC!conMn.ld.aon 4.B ac:ccwoancttwitnltltSI01rnwMt1Sl~of{...,T-,o1 !t!tF..,,_~R..,.._ l'LOI 1() ,~ Qrtur• .... MO.-.a .......... o~AI. COMnOlCN...:-:- Yn' lr,ICCDtdanceWlllh..,_M -P•OGotduret.olthtF~ r,oe ucnlolo!Un• 1 atllllfolowlheS..Pt.nR.-P10Ndllrn. llnOfoc ... rtQ11• ... ll'IQ......._IN~tlt9" 1 Submlllal ol Sitt PW! '-Pllklllion bV ~ lDl'lenn,N,boot)y[)reclofof~nu•ndBu~t~the ~b0111$QOmplela l. Ravoew and rec;ommendaoon bV Pl.lnntn0 Comm,HIOt\ .,,,.n optl(lllal Pul)li(.~ •Fll\aldli<:1$10ll-b-t CltYco,,.,d 11'1aeoc:,,Qar,o:eW11h-'rtdeN-l'roe.dvre.011N~PhOpl_.....,~~."'"lrltlnc:c eacllloldUNllahallolowlhe.SUP1aoRr.--P1ooeduln TIIIIOfocn& requ•n 111;eneral 1ht~91- 1 $,JDmlhld SM Plan~ byapf»Callt l Oete1_,.110nbyDreao<dPl9rwn;and~m.lll'ol. appkMIOll•oomolete 3 R ... _ tno ,_,.~by~ Comm,_ Wllh OpbOnal Pl,lblicHe_,,,,g 4F',,..oec-,b,r».Col.ll'lcll lr,a,cOOfO...at'll'tflAtbe:tt ll-..-rooacll:rndme,-wnoc,e __ ,~..,.,,,,._nee ll!achloldUNlv"lllllolooolleS4ePWIR.--Prooedlw" nn-,-•n III lll!'Will me 11;6:,ww,g _.,.,. I SubrnaaldSott"lanAppkatcnOyappkanl l t>ewl!WIUClnOyDredOl'of~.-.dBukw,;i,-..ir.. -·-J Rav-.-.dr~IOllby?larvw,gCoon,n,won~OIIOOfWII ...... ......., •Fll'lal~ovOhCouncil a. The zoning d1menS1ons for Unit 2. Lot 1 are modeled afte1 but not Identical to. the zornng requ irements for R-3 found m l he Fairhope Zonirig Ordmance The following exceptions apply · 1. The rrinimum lot width shall not apply. The lot dimensions shall be as shown on the PU D drawing . b. The req uirements for Unit 3 . l ot 1, are modeled after. but not identical to , the zonrng requi rements for R-3 found in the Fairhope Zoning Ordinance 1. The rrimmum lot width shall not apply. The lot dimensions shall be as shown on the PUD drawing . c. The allowed use for Unit 3, Lot 1 shall be lirriled to co nvalescent, nu rsing 01 assisted living home. d . Each lot in Unit 1 shall provide its own stormwater control and detention. e. This PUO document, along with the City of Fa irhope's Ordi nances, Regulations . and review processes wi ll provide a development that complies with the City 's Comprehensive Plan . l .\HLI ~ UNIT AND RIU I IT-OF-WAY ACREA0F ACREAUI-: EXCI UIJTNU ROW ACRhAIJFOF ROW UNIT! \90(, S\.l UNIT2 -ll{IJ UNIT; 106.l n,rALSITE 70 72 11 -------r--------,--------~-------~------~-------~-------~-------r---------,---_____ _j~======:'.J 0 0 I C ~'"I'" )SIOEWN..l<LOCAU:D -..i tuJ"F£A , aera.-.o-. AAU <M!f2 !Nf[,.,_,A.. Sfl'tt:!TS SHALL PROV\DI; 5'\"1111 J IIOl'WN.KS ALONc. r ➔E BLOCllPER.IMlf[IIAAO SfRliEf T'REUIN .. Pt.N,rr».OITR!II' "'~DC ST1'E.El ~ESSMAU.IIE H.lK'fEO OHITI F A\lt.~AY!!L...._AHO~~YffA~F"°"'tAOU $HM.LPAl'JIYIDl":t·1-ts«wAUtAHOSfM.Efffl£EINrl'\.ANTINOSTRIP TRC ESPMMO(OAfU'OC STM£fl JRt:Hlt1ALL--.£CT£0FAOt,, lf:CftOf,120,-IJ(~TTRffS.OtOTYOFfAftHOPf fftClOMDINAHCf fSPACINOK1.A.1$TEO FD,t OIWEWAYS ......0 UTl.l'fll!S) U<ilf1 Nl£RHAI. StDl""~ICS F~CAOSaH)LOCATIONS TO II'..~" OIJlll!NQr~...,_._ •it l"CM' 1 Tk'., ~ ...... ~ WllN ~ 10 M ~PIIOH"INGGA"""IIO #C),WO,,..QCN6C1N) ft4 .. O.?IW"'9!'tllN toc:.C't.Nl'l'1 UNIT3 1083AC UNr' I AY, LO!! "'1Q OC!!!_l81t DJ.2!1 SHALi. Ht<MOI' PARt(INO TO 5101:: O'-llEAA ___.,__ tOO O IOI D ~ .. 2 2 ;I. 111 "' - z :5 ... .. t: .. ... C ~ ... ., u z 0 u p 11 l "' .. i5 ! 0 ::E 0 ¥ e' ... 0 ::E " 8~ E q·1 ,ii N ~ u ~ PLANNING COMMISSION RECOMMENDED APPROVAL : SEVEN (7) AYES, ZERO(0) NAYS ZC 20.10 Klumpp PUD Amendment Property Owner /Applicant: Gayfer Village Partners, LLC; Mr. Tom Mitchell; Mr. Bill Mitchell General Location: Northwest intersection of SR 181 and Fairhope Avenue (CR 48) Project Type: Planned Unit Development (PUD) Number of lots: 15 Unit 1-13 Lots (19.03 Acres); Unit 2 -410 Units (41 .03 Acres); Unit 3 -106 Units (10.63 Acres) Zoning District: PUD Parent Parcel PPIN Number: 236701, 24160, 316793 Engineer of record: Scott Hutchinson, GMC Surveyor of record: Goodwyn, Mills, and Cawood , Inc . School District: Fairhope East Elementary, Fairhope Middle and High Schools Report prepared by Hunter Simmons Comments: The applicant is seeking amendment of PUD ordinance number 1664 related to the Klumpp Planned Unit Development adopted November 25, 2019. The subject property is located at the northwest intersection of State Highway 181 and Fairhope Avenue/County Road 48 and extends north to the southwest corner of State Highway 181 and Gayfer Avenue/County Road 30 . At the request of the applicant, Case ZC 20 .10 was tabled at the December 7, 2020 Planning Commission meeting. The revised plan more clearly states the applicant's objectives . Unit 1 still consists of 13 B-2 lots. Unit 2 and 3 are based on R-3 zoning . Pedestrian connectivity was added throughout the site and along the perimeter. The buffer along the westernmost perimeter was increased from 30' to 45' and now includes a screen , as well as a walking trail/sidewalk. Staff Recommendation Staff recommends Case# ZC 20 .10 Klumpp Planned Unit Development {PUD) amendment for PPIN's 236701, 24160, 316793 be APPROVED subject to the following conditions: 1. A master drainage plan shall be prepared for the entire site and included with the initial subdivision application creating units 1-3 2. City of Fairhope site plan review (Zoning Ordinance Article II , Section C.2.) shall be mandatory for each lot within units 1-3. 3. City of Fairhope subdivision regulations (including multiple occupancy project provisions as applicable) shall be required for the creation of all lots and units within the Klumpp PUD. 4 . A 20' greenspace and tree preservation strip shall be provided along Hwy 181. 5. Unit 2 will require 20% greenspace as shown . Provided retention/detention shall not encroach into required greenspace other than those methods approved within the City of Fairhope Subdivision Regulations and/or as approve during MOP/Site Plan Review . Public Hearing Jeremy Sasser of 438 Swaying Willow Avenue -He stated concerns with the number of access points to St . Hwy. 181, Fairhope Avenue, and Gayfer Road Extension . He suggested the uses be limited on the corner lots, limiting the number of drive-thrus, and asked about screening of the parking and dumpsters . Scott Hutchinson of Goodwyn, Mills, and Cawood, Inc. was present on behalf of the applicant . Motion: Jimmy Conyers made a motion to accept the staff recommendation to APPROVE subject to the following conditions : 2nd: 1. A master drainage plan shall be prepared for the entire site and included with the initial subdivision application creating units 1-3 2. City of Fairhope site plan review {Zoning Ordinance Article II, Section C.2.) shall be mandatory for each lot within units 1-3. 3. City of Fairhope subdivision regulations {including multiple occupancy project provisions as applicable) shall be required for the creation of all lots and units within the Klumpp PUD. 4. A 20' greenspace and tree preservation strip shall be provided along Hwy 181. 5. Unit 2 will require 20% greenspace as shown. Provided retention/detention shall not encroach into required greenspace other than those methods approved within the City of Fairhope Subdivision Regulations and/or as approve during MOP/Site Plan Review. 6. Construction of sidewalks shall be done at the time of development of the internal roadways . Hollie MacKellar 2nd the motion and the motion carried unanimously with the following vote : Vote: AD-Aye RB-Aye HK-Aye JW-Aye LT-Absent HM -Aye JL-Aye CHB-Absent JC-Aye City of Fairhope Planning Commission January 4, 2021 ZC 20.10 -Klump PUD Project Name: Klumpp PUD amendments Site Data: 80 acres (approximately) Project Type: Planned Unit Development (PUD) Jurisdiction: Fairhope Planning Jurisdiction Zoning District: Planned Unit Development (PUD) PPIN Number: 236701,24160,316793 General Location: Northwest intersection of SR 181 and Fairhope Avenue (CR 48) Surveyor of Record: Goodwyn , Mills, and Cawood , Inc. Engineer of Record: Scott Hutchinson, GMC Owner I Developer: Gayfer Village Partners , LLC Mr. Tom Mitchell Mr. Bill Mitchell School District: Fairhope East Fairhope Middle and High Schools Recommendation: Approve with Conditions Prepared by: Hunter Simmons Legend • :ccoF Corp. lirrits B-2 -General Business District PUC -Planned Unit Development R-1 • Low Density Single-Farrily R-2 -M&dium Density Slngt&-Farrily • R-3 • High Density Slngt&-Farrily • R·A • R&SldentiaVAgricutture District COF Planning Jurisdiction Page 4 o f 6 APPLICATION FOR ZONING DISTRICT CHANGE Prope rty Owner / Leaseholder Information Name: Gayfer Village Partne rs, LLC Phone Number: _25_1_-9_2_8-_00_7_1 _____ _ Str eet Address: PO Box 130 ----------------------------City: Daphne State: AL Zip: _3_65_2-'-6 _____ _ Applicant / Agent Information Ir different from above . otanzed letter from propeny ov.ncr I required sf n a ent 1s u ed for repre ntatio Name: GoodW]'n . Mills & Cawood. Inc. Phone Number: (251) 626-2626 Street Address: City: Daphne State: AL Zip: --3-6-52....,6 _____ _ Current Zoning of Property: ____ C_ou_n---'ty_U_n_z_on_e_d ___________ _ Proposed Zoning/Use of the Property: Planned Unit Development (PUD) Property Address: 2075 1 State Highway 181 . Fairhope , AL 36532 Parcel Number: 46-05-15-0-000-001 .001 , 46-05-15-0-000-001 . 000 , 46-05-15-0-000-001. 003 Property Legal Description: --~Se~e---'a_tt_ac_h_e_d ______________ _ Reason for Zoning Change: To allow for the construction of a mixed use resident ial / retail developmen t Property Map Attached Metes and Bounds Description Attached Names and Address of all Real Property Owners within 300 Feet of Abo e Described Property Attached . @ @ NO NO NO Character of Improvements to the Property and Approxjmate Construction Date :---,--- The improvements will consist of new roadways , reta il shops and apartments . Approximate start da te is March 2021 . Zoning Fee Calculation: Reference: Ordinance 1269 I certify that I am the property owner/leaseholder of the above described property and hereb submit this application to the Ci ty for re view. *If propert I is owned b y Fairhope Single Tax Corp. an authorized Single Tax representative shall sign<:: application . Tom Mitchell --~-1==-__:@1:~::::::=:_ _____ _ Pro O wner /Leaseholder rinted Name Signature Fairhope Single Tax D np :-(lf.Applicab}e);i <::'I . 0 l l J 1010 i BY:.L6. ......... . Summary of Request: The applicant is seeking amendment of PUD ordinance number 1664 related to the Klumpp Planned Unit Development adopted November 25, 2019 . The subject property is located at the northwest intersection of State Highway 181 and Fairhope Avenue/County Road 48 and extends north to the southwest corner of State Highway 181 and Gayfer Avenue/County Road 30 . The subject property is bordered to the northwest by the adjoining White Grove subdivision, zoned R-2 medium density single family residential , and bordered to the southwest by the adjoining PPIN 14493 zoned R-A residential agricultural. The subject property adjoins ldlewild Subdivision (R-2) to the south, separated by the Fairhope Avenue right-of-way (ROW) as well as various properties comprising the southwest intersect ion of Fairhope Avenue and HWY 181, all zoned B-2 general business district. All remaining properties adjoining subject property are separated from subject property via ROW and are located within unzoned Baldwin County Planning District 14. Comments: ORIGINAL PUD The subject property is comprised of one large (PPIN 236701) generally rectangular parcel fronting AL HWY 181, Fairhope Avenue, and Gayfer Road Extension, all paved, publicly-maintained streets . PPINs 24160 and 316793 are inclusive of PPIN 236701 and will likely become functions of a future subdivision. The site plan supporting the original PUD (Case number ZC 19 .13) is included above in excerpted form and color- coded to reflect the "units" proposed for the PUD . The requested site plan that amends the PUD ordinance is included below. 1 ZC 20.10 Klumpp PUD Amendment -December 7, 2020 PROPOSED PUD AMENDMENT (Revised for January PC Meeting) • Unit 1 ... Al.~-r.c,-:.r,:.,~~= lllfU~ATllttO.C ITiaU'MIU.w.i•lll&1'Kl"'CIU WC,Q,lkt-llf(Mi,U,,JTMf.s:tO#CIT'I'~~-~ fl'A0Noolil>AMl'tOflJlt~'l'llrMllmLA'U I l'H.=.~ _..Olacc:NaCJMIO"II _... .......... .., ___ _,__.._ -... ...... ....,. -OIWl'I UNIT3 -.aiv::... o As approved Unit 1 (28 .79 acres+/-) contains 16 lots with allowable uses and lots sizes identical to B-2 General Business District Zoning. The developer requests , via inclusion of drawing 2 of 2 in the PUD ordinance, self-imposing the Site Plan Review procedure as included within Fairhope 's Zoning Ordinance . o As requested , Unit (19 .06 acres+/-) will contain up to 12 lots . Si milar to the original PUD, the requested Unit 1 contains allowable uses and lots sizes i dentical to B-2 General Business District Zoning . Also similar to the original PUD the developer requests , via inclusion of drawing C3 .01 in the PUD ordinance, self-imposing the Site Plan Review procedure as included within Fairhope 's Zoning Ordinance . • Unit 2 o As approved Unit 2 (23 .20 acres+/-) depicted in light red on the facing page identically replicates the use of R-5 High Density Dwelling Residential (10 units per acre, for 232 units total) but requests the lot size shown on the site plan drawing 1 of 2 in lieu of the allowable number of dwelling units included within Table 3-2 in the City of Fairhope Zoning Ordinance . Similar to Unit 1 Unit 2 w i ll be required to follow the Site Plan Review procedure included in The City of Fairhope Zonin g Ordinance as a self-imposed requirement of the PUD . o As requested , Unit 2 (41.03 acres+/-) closely replicates R-3 High Density Single -Family Residential but requests the lot size and approximate building layout (Up to 233 Units) shown on the site plan drawing C2.0l. Similar to Unit 1 Unit 2 w i ll be required to follow the Site Plan Review procedure included in The City of Fairhope Zoning Ordinance as a self-imposed requirement of the PUD . • Unit 3 2 ZC 20 .10 Klumpp PUD Amendment -December 7, 2020 o As approved Unit 3 (14 .11 acres+/-) depicted in light green on the original site plan contains 67 residential lots modeled after an R-3 zoning district with modifications that reduces the m i nimum lot size and increases the allowable lot coverage. At the time of development activities unit 3 shall follow the City of Fairhope 's Subdivision Review Process and comply with the current Subdivision Regulations in addition to the requirements of the PUD ordinance . The original submission to the Planning Commission included 77 single family lots, however the reduction to 67 single family lots reflects conditions of approval required by the Planning Commission at the time of consideration . o As requested, Unit 3 (10.63 acres+/-) removes the single -family residential lots from the development and proposes requirements modeled after R-3 zoning district (approximately 59 Units) with modifications that reduces the minimum width . The allowed use for Unit 3 shall be limited to convalescent, nursing, or assisted living. The applicant indicates they do not wish to provide a layout of the proposed development for Unit 3 at the time of PUD amendment, but wishes to self-impose the site plan approval process for Unit 3 should the PUD amendment receive approval. The following was provided within the December staff report . Notes in red highlight the amendments made in the applicant's revised plan . Fairhope 's Zoning Ordinance (Article II Section C.1.e} contains nine (9) criteria by which an application for re-zoning shall be reviewed: (1 ) Compliance with the Comprehen sive Plan; Response: The intersection of Hwy 181 and Fairhope Ave is listed as a Village Node within the Comprehensive Plan . "Highway 181 / Fairhope Ave presents an additional village opportunity. While this area has seen a growth of large retailers in the recent past due to regulatory limitations (i.e. significant property located outside of the City Limits in unzoned Baldwin County}, it is in the early stages of village pattern development. River Mill Subdivision is connected to both Fairhope Avenue and Windmill Road. The residential areas around Gayfer Avenue and Blueberry Lane are built in accordance with the City Subdivision Regulations and provide neighborhood level greenspace , sidewalks, streets, trees , oc:::::ac:::ac -.o.o and connectivity . While this area will evolve over time, the "bones" of a village are generally in place." 3 ZC 20 .10 Klumpp PUD Amendment -December 7, 2020 Specifically, in regard to Village Nodes, the Comprehensive Plan reads "Simply evaluating development at these areas (Village Nodes) will not result in a Village -it will take a proactive effort". The following excerpt from the Comprehensive Plan is provided for guidance: Size -They should be 30 ,000 to 180,000 square feet in commercial/ mixed-use development. Street Location -They should push as close to the street as possible Architectural Guidelines -There should be bui lding design guidelines that deal with arch itectural themes, materials, and massing . There should be an architectural "anchor", a building with a distinct and focused character, in each v illage. Automobile Access -Automobile access will be important to the success of the v illage, thus it should be incorporated as appropriate. However, addressing the location and aesthetics of parking lots will be critically important. Vehicular access from the supporting and existing roadways is also important. Integration of Right-of-Way improvements, turn lanes, signals, sidewalks, landscaping, street lighting, push-pad signals , crosswalks, and similar infrastructure should be comprehensively evaluated by the City. This would result in the Right-of-Way and and roadways being upgraded in conjunction with the development. Internal circulation must not be the typical maneuvering areas through a large parking lot, but seek to create more of a streetscape experience with "on- street" parking in either a parallel or diagonal configuration. A good operating principle would be that large surface parking lots should not dominate the view of building frontages . Vehicular access is always i mportant and should be accommodated ; however, parking is a net negative in terms of visual quality. (2) Compliance with the standards, goals, and intent of this ordinance; Response: PUD Planned Unit Development: This district is intended to encourage innovative development that meets comprehensive plan goals and is tailored to the unique constraints and conditions of a particular site . This district allows flexibility in uses, designs, and building layouts as opposed to other zoning districts to better serve community needs. While the original PUD's regulating plan was general, deferring specifics to future Site Plan Reviews, there was a framework for meeting the intent of a PUD . The proposed amended PUD, by being overly general, makes it difficult to recommend approval. The applicant has self-imposed a site plan review for all units. The first unit developed will require installation of Unit 2, for example, should not require a future Site Plan review. It is feasible to include a comprehensive site plan (for Unit 2) as part of this PUD process with landscape plans, architectural examples, etc ., and, at the least, include pedestrian circulation for the entire PUD . It would also be prudent to include guidelines for the Units 1 & 3 to ensure they are developed consistent with Fairhope's Comprehensive Plan, which may include build-to/setback lines, landscape buffers, planned green space, plant selections, etc. 4 ZC 20.10 Klumpp PUD Amendment -December 7, 2020 Unit 2 is now proposed as illustrate on C2 .01 and includes up to 233 units. Sidewalks were provided within Unit 2 and the westernmost buffer was increased to 45', which now includes a sidewalk connecting all three units with both Fairhope Ave and Gayfer Rd . Within the 45' buffer, the westernmost 10' will be planted to provide a buffer/screen consistent with the City of Fairhope Tree Ordinance . Street Trees will also be planted in accordance the City of Fairhope Tree Ordinance . Staff does have some concern that some conflicts exist between retention/detention, possible wetlands, and green space requirements within Unit, but those are not part of this review. Unit 2 will require a site plan review as well as an MOP review in the future to resolve the above - referenced concerns . Staff recommends a condition of approval to memorialize the 20% greenspace per density shown and urge that retention/detention should not be placed where greenspace is currently shown unless installed as an improved amenity, such as accessible ponds with landscape consistent with the City of Fairhope Tree Ordinance . A condition of approval of the previously approved plan required a master drainage plan at time of subdivision and staff makes the same recommendation for the current application . Unit 1 lots require parking to be located to side or rear of buildings . The following was submitted by the applicant to further support a comprehensively planned development. 4 . In attempt to achieve a cohesive character of residential development in Unit 2; Fronts of all residential building units within Unit 2 shall fall within in a 20' m i n . and a 40' maximum build to zone from the street, with the exception of buildings impacted by utility locations, lighting, or buildings located along corners, or curves in the street in which case these buildings may vary from this build-to zone . 5. In attempt to achieve a cohesive character of development in Unit 1 and 2; All building facade materials shall be constructed of like materials set, in precedent, by the 1st site plan development submittal. (3) The character of the surrounding property, including any pending development activity; Response: The comprehensive plan describes a village center at this location and states that the "bones" are already in place . The surrounding properties are unzoned, RA, R-2, and B-2. The original PUD provided adequate transition to the_single-family residential along the western boundary, while also allowing denser and more intense uses along the highway corridor and internally within the site . Staff is concerned that the submitted PUD amendment, with its removal of higher-density single family residential, diminishes the transition of use and transition of density contemplated by the comprehensive plan . The westernmost buffer was increased to 45' and will include a 10' screen abutting adjacent property. (4) Adequacy of public infrastructure to support the proposed development; Response: Fairhope Public Utilities can be made available during the subdivision process; however, staff urges the applicant to contact Fairhope Public Utilities in short order to discuss utilities, 5 ZC 20 .10 Klumpp PUD Amendment -December 7, 2020 particularly access to sanitary sewer. The "upsizing" provisions of the subdivision regulations will likely be invoked if development activities proceed. (5) Impacts on natural resources, including existing conditions and ongoing post-development conditions; Response: Wetlands are present on the subject property and all wetland delineations, reports, ordinances, and buffers will be required during the development process. (6) Compliance with other laws and regulations of the City; Response: At the time of development all applicable laws of the City will be applied. (7) Compliance with other applicable laws and regulations of other jurisdictions; Response: At the time of development all applicable laws will be applied. (8) Impacts on adjacent property including noise, traffic, visible intrusions, potential physical impacts, and property values. Response: As mentioned previously staff is concerned about the loss of single family residences within the PUD, and the possibility of higher-density multi-family located directly-adjacent to lower density (R-1 and R-2) single family residential. The westernmost buffer was increased to 45 ' and will include a 10' screen abutting adjacent property. In addition, pedestrian circulation should be designed connecting the subject property with adjacent and surrounding properties. Sidewalk connections were made throughout the site connecting all units together, as well as connecting to the perimeter sidewalks and on all public roads . As opposed to the previous plan , sidewalks and street trees are provided fronting Hwy 181. Planning Commission may want to discuss when installation of perimeter sidewalks and street trees are installed . (9) Impacts on the surrounding neighborhood including noise, traffic, visible intrusions, potential physical impacts, and property values. Response: As mentioned previously staff is concerned about the loss of single family residences within the PUD and the possibility of high-density multi-family uses located directly-adjacent to lower density (R-1 and R-2) single family residential uses. As proposed, B-2 and R-5 abut R-1 and R-2 properties. Staff recommends a better transition to adjacent properties that may come in the form of larger buffers, greenspace, or less dense housing . The westernmost buffe r was i ncreased to 45 ' and will include a 10' screen abutting adjacent property. Per the City of Fairhope Tree Ordinance, a 20 ' preserved greenspace shall be provided along Fairhope Ave and Gayfer Rd . Development along Hwy 181 was not contemplated when the Tree Ordinance was adopted . Staff would like to r ecommend a condition of approval that the 20' preserved greenspace be provided along Hwy 181 as well. To be clear, this does not impose an additional 20' to the required setback, but rather preserve the space within the setback for the preservation of trees . Staff Recommendation: 6 ZC 20 .10 Klumpp PUD Amendment -December 7, 2020 Staff recommends Case# ZC 20.10 Klumpp Planned Unit Development (PUD) amendment for PPIN's 236701, 24160, 316793 be APPROVE subject to the following conditions: 7 1. A master drainage plan shall be prepared for the entire site and included with the initial subdivision application creating units 1-3 2. City of Fairhope site plan review (Zoning Ordinance Article II, Section C.2.) shall be mandatory for each lot within units 1-3. 3. City of Fairhope subdivision regulations (including multiple occupancy project provisions as applicable) shall be required for the creation of all lots and units within the Klumpp PUD. 4. A 20' greenspace and tree preservation strip shall be provided along Hwy 181 . 5. Unit 2 will require 20% greenspace as shown. Provided retention/detention shall not encroach into required greenspace other than those methods approved within the City of Fairhope Subdivision Regulations and/or as approve during MOP/Site Plan Review . ZC 20.10 Klumpp PUD Amendment -December 7, 2020 ~ ~ ~=§ !rt I ---O'll'l0ICl)O ! --- ! i~e OVERALL SITE PLAN SCALE: f"a100' C1.01 --.!...oL._3 '1 I I I I J ___ ~~--- KLUMPP PARCEL -DOlYILOPW[t(T f-Al,U,t,MA OMCProject CMOB19018B 17 DECEMBER 20:io I I I l~I I ~ ' I' I• I r I "-• : ! l ij I } I 1039 1.bin StfWI 0.,,~M,AL3'S2' T ll!it.12S..2626 ,.c ______ ,..- 1 \ -,, 1. ----~~~----. I -<:r::_~ ·t \ ,/ \ \, \ \: ~;::;~~:;~J;~/ _I ~ \/ ,--~~-\ I-: ) , • .tie \.._l __ fL) I \ /' l ,i ,/Joe; V \I '~ ,, '/ -,---->-r ~ \• . ",rc$11"n~~r--\- ,, ,, ..... ,..-,l __ ............ ,,,-...... llffilllW..l.~A~,-:i~:w~~~ ...... -:::~~,=~ - SIO[W-'U<ONTHl EASTiiltN JDGEOHINIU. :: UN ~;,;/ _<==t ____ .J.0,63 A,,C;:,.....-' ,,,.,,/ /:t .. 1 ·=}}:j cn«lll'IM. '"-.., r-v I ----,=~:.:~--,-+-~~ m ~ 1ii 0 :le u \: o' /;: u :le "' ~ " IH ~ t i I~ " I J!' I 11 .-~- £ .LINll rp : i ~ i . Kl i i G') :<: ,....,. " , --ITAttCJ#~ COU,(f'fO,IAl.CJWl!'I COMMU,ICI.AT A RMJICW)Sf'IG Al fitlii:t«llll™USTCOIIIN!R 0F $£cn0f,11, 10illft&W'680UTK IWIGC l tAIT.MI.DWIN co.MT1 IUIINM.NJN THF.Na: WE5'I lllOffllfHE"°"fWl#tEOFMIOSEcn)llltSIJl!OS&rtCTTO•POINT ~ 'ntfHUSOUT'Hll).21,Jll\'UT llnK~TOACN'f'(OfllCIMaww!JtON fHf: IICUTMIIGtff.ol-JIIAYl.fi£0FO,.VffAAvu.Jt:F0RTHEPOWTOJ"HO,Nt;.'lllQI TMiPAC>PEJnY~CUCA:18(0 S41>1'01NTIEINO™f NCMffl«ASTCOI,. Of''WNU:Ol'IO'Wlt:.M.eOMl«lfll,UNITiffV ~ICIIMJICll00M$1.iOl 1Moll .. N0tl Mt..DWINCOI.M'YP'fllOIA.TE!AECOflOS.OQJ'lllJ,,UEne<:l.lOU'fllONJ.1,wtsr. -'I.Of«.nEUSTUtEOIFSMOllllll()ll,1$IO 12N .• f1ETTO ,.W'PCDACIINI w.vtl<ERATTHE80UTHEAST(X)ffJEAOfS...:,5\l&OMSION.R.-ilHENCiSOUTH 00·-·0eo,\"El'T. 1117 ltFUTTOACN'f'CDA:CBNl~RON'THE NOITTHHIGIJr• Of-'lfAY UtE Of FMIHOI'£ A\IEM.IE, ft!JN ntEl«:E 90UfHe.56•311 FMT. At.ONG MOAIC»ff.Qf'.Ji/lAYUIE,111t'1FEE1 TOACN'f'CDN:!Wlt.WIKEll_ftlJNTHl;MCE HQllrH •~1 EAST, 1».lefEEl TO ii CNl'f'l':DJIIAM ~ OH THE~f'.!.T RIGHT-OI-JttAYu.E06'COUITYR0i'.Ol!7,"-""!Tl1fNCENO«THOO,.,U.181EMT. M.OWG&IIIIO'IYUl ll!OtO.(Jf.WAYlM.ta.22 f"1 IOA~D~IIW'cKUI, TttEJ'ICEOl'JHTN.t'NOft™00-44•ta EMT,-.i.Ol'fG&IClltlQKT.O,,..WAY,1crr.H r El!:J TOACN'P'fO"f;IW!MMJWll:TteQIIIUHNOlffHIM~UST • .r.u:>oiGU.IO ltljtfl..(Y,WAY,ICO.:;wFEETTOACIPf'l!OAl:l.ul~TMlNCl!:"-INNOfrTHO). -l&EA&T,H..Oll'tGMIOMltff-01"~1,:r,,».OOF[IETTO,.CN'f"(OFWIMI:~. IIVMTHOCENOl'ffl100-+l-1.U.ST.ALOHGSAIOROft,OFJlll,,.'f\M.11i2..9$Ttllf TO,.CloP91:0N:D,t,ll;I.Wtl(Clll~TIE$01.f1HRN)Ht.QF.WAYUI-EOFa.-.Yrt'.R AVE!il.lE, ltl.N THENCE 90VTHN-S7,21WEflT, M..ONO SAi) RIGHI-Of-\Y"-V UHE, 1182.-~[CTTOTHCfl'OIHTO,l!ICOINf,fHG OCIN'l~NNGJSlJ,a:IE.l,t.lOAEOR , ... 1. 0r....__-,. ................................... ,,,, __ , __ .. ... CRIOO<J-loilll.•---••pp-ol. l lKllbtofNdo--ptoriilo 1fld""'I01oirl~dl ....... ,_odj,Kent pr-n;,,,<Ml"'°'t>c_pt'C __ , J . ==!::-::,:::,:,.":!,~':"'°' .... ,.,~uei irl O!to.,_IO_o...,,_ct,.,_,offfliclontlol6o ....... ntirlUMt; Fr-•ofolrtoilill-~-•-U.•l-tol-irlollJ'-.ofld •lltl-.,S,,.,ffl_lO_l,.,...lfio•fffl ...... lho.,._,....,of_llll' .....,..i.,.-,....._...,.,lllh,lftl.otlMldilliploato,d-.-n,o,-"''""1tr-1r1-u..-i..ld1np.....,..,.,1r....,,w.---. !i lnott-•o-•--<t.of0<1orof6o ...... ntll!Unlll-t;AI ~~-=-===.=.i"':.•dof_.o......,_Ml,irlJlf---. 5.1. ~ .. .._.,,....,__, ....... ,.r1o1 ... ---., ..... , ........ ~-=~-= ....... •fld•--... ,11o--...-. -lb-ioolUfllll.Unlll,ofldUflllJlobwlll ... .,_"l ___ ua.d ., ___ lho5ao ___ lo,oad\klt. 1. AltrM1atldlo"""'-"'"'"'lolwll ... 1NV-•liol""ir,loc.ol-..:.P, o,dina"°"-•--000<dirlot-.lwi!~lhoelly..-1otatryo,-. c:d -u::J TYPE "A" TYPE,_,:'c" TYPICAi ROAD SECTIONS Slal be~ned-OONINd9d lrl B S..Pa,lungofll'le .......-..-u.Sto<-..~of -r-lol Fa1r11opeZon1ng ... F...,_Sutld,..ionR~ PIJOI Onlmnce lnKCOldance_,..__11-P-oflheFlliltloJl9Zonr,g~. -1DtoftJn!l1.-1o1ow ... SllePlanR-P,_.TIMlp,uce90 ~ ..... ~lhe~ .. : 1.SutmllalofS..Pi.n~by•pplicarrl 2.0.~by~of~•ndBulldllr,g1hll .. -·-,.~,nd~byPll""lngC-lon-(IJICbtlll --■.Firel6-cillon •~c-..:, ln ■c:ICOftlllnce_..__11-P~Oflhe '""-....... ~ .... --. -IDtOfVnil2,hlllolDwhS-.PIMR-~.Th•p,uce91 ~ ..... ~ .. ~ .. : 1.SubmllalOfSMPi.nAppllmbonbyappllcant 2.0.-by~of~•ndB~hl .. -·-3.R......, __ ..,PIIMlng~ion-OJICbtlll --■.Flnal~lon· ...... Councl ln~-Alllc:lall-r,...,.__OflhOI ~-..,.-~..,...---, -IDtOfl.lnitlat.lfolowlwSllePlanR-~.Th•-• ~ .. ~,,,.~-., 1 5'll>fflll:l■IOfSMP'w,Applcellonl>yapplk:arrl 2. ~by-0.-0fPlannln,glond&ldlftghl ... -·-l.R-lond~byP'-nrwrg~----... Flnal....,_bn.,.,Ct,Counc:11 •· The zoning dimentlont b Unil 2. Lot 1 ara modeled eflar, but not iderr&el 10. the zonng requlremer,u; k>r R-3 found In the F.;rnope zorwig ~-The lollowingHceplionsappl)': 1. The minimum lot width •hlll not apply . The lot dim__,.. ahaH ben 800'WTl on the PUOdrawing. b. The requifemenla b-Unil 3. Lot 1 • .,-, modelad 1111111", but not idenlicel to. lhe zoolng requi.-ita for R-3 lound-' the Fairhope Zoning Ordinllf>c;e. 1. Themlnimumlotwidltlshellnote~.The lotdmenaionllshallbe••M'IO\ll,l"lonthePUDdrawiog. The allowed UM for Unit 3. Lot 1 ahaff be limited to conYlllncene. r,.nng or asaisted lf,'ing homa . d . E.ch 101: in Unit 1 sh.an p,CMde ii■ own atomrwatar c:oncrol ~ de4enlion. • This PUO o:loeumen1 • .iorig wilt! the City o f F•lrhope'e Or~. Regui.tionl, end review~ w11 provide• development lhet complie,s witti the City'1Comp1aheraHaPlan I I ,.t _j_ ___________________________________________ -----1.:'=====::::'J November 30, 2020 City of Fairhope attn: Emily Boyett Re: Case no. zc20.10 "Klumpp Parcel" Dear Emily, Enclosed herein are comments concerning the proposed site plan. The northernmost entrance on SR 181 appears to be a Right In-Right Out configuration. Until SR 181 is a divided highway between Gayfer and Fairhope Ave., motorists are likely to ignore common sense, pavement markings, and signage and the RI-RO concept. Evidence: watch Walmarts RI-RO accesses. The middle entrance on SR 181 appears to be yet another trafffic signal. Could a traffic circle be a better option? Fairhope does not need another traffic signal on this section of road. The south entrance on SR 181 simply to close to the existing SR 181/ Fairhope Ave. intersection. Again, a Right In-Right Out configuration works in theory only. The easterly entrance on Fairhope Ave. is the worst potential problem. This is already a traffic mess. There are three uncontrolled accesses nearby: Bay Shore's Gas station, the car wash, and Golden Auto Sales. The 8-1/2 x 11 inch drawing provided by the city is deficient in that it does not show those three accesses. Plus the easterly entrance appears to be uncontrolled. A mess. It might be time for the city to clean up the existing accesses here. Perhaps a raised concrete median on Fairhope Ave. is warranted, similar to what is sorely needed on Fairhope Ave. at Walgreen's, to stop dangerous and illegal movements. The westerly entrance on Fairhope Ave. is difficult to evaluate, since the existing intersection at Idlewild Blvd. is not shown. Therefore, one cannot discern how the new entrance will align with Idlewild Blvd. Finally, I count 236 new residential units on the proposed project. P city can accept this much growth. Or this project will help push current water supplies , sewer capacity, and the electric grid to a tipping point. Each new development adds cars to Fairhope Ave. Each new development adds motorists who simply won't adhere to small-town speed limits, won't yield to pedestrians , and won 't fo ll ow basic lane mar kings . Thank you. Sincerely, Michael Warren 218 Royal Lane Fairhope, AL 36532 Arizona RCE 37820 --- ( Foor \ R.l~~T- ~ ~ l N 'C.f \'\ (0..\ ~,~ R\&l-tT JJ'v~ l l I t ou.-r Frank & Elvira Connell 20605 Lowry Drive Fairhope, AL 36532 November 27, 2020 City of Fairhope Planning Commission Reference: Gayfer Village We have three issues concerning the proposed development. 1) There is a long standing problem of storm water retention in both the south east and south west corners of our development, White Grove. We had been told that once the former Klumpp property was annexed into the city that the problem of storm water runoff would be resolved. We want to insure that problem will be resolved either prior to or concurrent with the Gayfer Village development. 2) We request that the 8 to 10 foot fence separating the proposed development from our property be erected and subsequently maintained early in the development process in order to mitigate both the noise, dust and debris on our property created by the development 3) We have a large live oak tree on the eastern edge of our property bordering the proposed Gayfer Village development. Several large limbs extend 10 to 15 feet into the proposed development. We are concerned that if that branches are cut off the balance of tree may fall onto our house. We request that a knowledgeable City representative from the Landscape Section of the Public Dept. come inspect the tree and the situation I described. In closing please inform us of the proposed start date of the development. Thank you, Frank & Elvira Connell