HomeMy WebLinkAbout04-21-2026 BOA Agenda Packet
Council Chambers, Fairhope Municipal Complex, 161 N Section St
For more information, please visit: fairhopeal.gov/departments/planning-and-zoning
Sherry Sullivan
Mayor
Council Members
Andrea F. Booth
Jack Burrell, ACMO
Jimmy Conyers
Joshua N. Gammon
Jay Robinson
Lisa A. Hanks, MMC
City Clerk
Kimberly Creech
City Treasurer
Fairhope Board of Adjustments Agenda
April 21, 2026 – 5:00 PM
1. CALL TO ORDER
Anil Vira, Chairman Ryan Baker
Frank Lamia, Vice Chairman Donna Cook
Bryan Flowers Hunter Simmons, Secretary (interim)
2. APPROVAL OF MINUTES
• February 23, 2026
3. OLD/NEW BUSINESS
OLD BUSINESS
None
NEW BUSINESS
A. Appointment of Board of Adjustments Secretary
B. BOA 26.03 Public hearing to consider the request of the Owner, Lucinda
Chappelle, for a Building Height Variance on property zoned R-2, Medium Density
Single-Family Residential District. The property is located at 210 Gayfer Court and
is 0.72± acres. PPIN#: 22366
C. BOA 26.04 Public hearing to consider the request of Murphy Oil USA, Inc., on
behalf of the Owner, RW Battles, LLC, for a Special Exception to allow
construction of an Automobile Service Station on property zoned B-2, General
Business District. The property is located at 18186 Wright Blvd and is 1.13± acres.
PPIN#: 391372
D. BOA 26.05 Public hearing to consider the request of Murphy Oil USA, Inc., on
behalf of the Owner, Corte Cave/Mitchell 1, LLC, for a Special Exception to allow
construction of an Automobile Service Station on property zoned B-2, General
Business District. The property is located at the northwest corner of the
intersection of State Hwy 181 and 104 and is 1.18± acres. PPIN#: 626309
4. ADJOURN
Page 1 of 63
Fairhope Board of Adjustment Minutes
February 23, 2026 – 5:00 PM
Fairhope Board of Adjustment Minutes – February 23, 2026 1
ADMINISTRATIVE
The Board of Adjustments met Monday, February 23, at 5:00 PM at the City Municipal Complex, 161
N. Section Street in the Council Chambers.
Present:
Staff: Hunter Simmons, Planning and Zoning Director; Payton Rogers, Planning and Zoning Manager,
and Janine Saykes Code Enforcement
Chairman Vira called the meeting to order at 5:00 PM.
APPROVAL OF MINUTES
• Approval of the Minutes – January 22, 2026
Frank Lamia made a motion to approve minutes from the January 22, 2026, meeting.
Ryan Baker seconded the motion and the motion carried unanimously with the following vote:
AYE: Anil Vira, Frank Lamia, Cathy Slagle, Donna Cook, and Ryan Baker.
NAY: None
ABSTAIN: None
OLD BUSINESS
None
NEW BUSINESS
A. BOA 26.01 Public hearing to consider the request of the Owner, Karen Rice, for a 15-foot Front
Yard Setback Variance on property zoned R-1, Low Density Single-Family Residential District.
The property is located at 11 Greenbrier Lane and is 0.38± acres. PPIN#: 113535
Payton Rogers, Planning and Zoning Manager, presented the above request made by the
Applicant. Mr. Rogers shared the aerial and zoning maps.
Staff recommends Denial of BOA 26.01 – 210 Greenbrier Lane request for a 15-foot Front Yard
Setback Variance.
Chairman Vira asked the Applicant if she would like to speak.
Page 2 of 63
Fairhope Board of Adjustment Minutes – February 23, 2026 2
The Applicant, Karen Rice, 219 Saddle Lake Drive, Alabaster, Alabama, shared additional
materials with the members. She stated that on the maps she distributed, with the curve of the
cul-de-sac, her house would be even with the next-door neighbor, with the 15-foot Variance.
Ryan Baker asked why the Applicant is asking for twenty-five (25) feet when thirty (30) feet would
work. The Applicant was told she would need a wider driveway. The HOA doesn’t allow a front
facing garage. She also prefers to build a one-story house.
Cathy Slagle asked when the Applicant purchased the lot. The Applicant said in June last year.
Ms. Slagle asked if she knew of the gully. She replied yes. Ms. Slagle asked if the wall of the gully
is secure and the Applicant responded, yes as far as she knows. Ms. Slagle asked if it fills up with
water. The Applicant stated it does not.
Hunter Simmons, Planning and Zoning Director, stated the gully is a concern.
Anil Vira asked if building closer to the cul-de-sac would help with the gully problem? Mr.
Simmons stated that we are not approving a Site Plan within this Variance. Mr. Vira asked if the
Board could add stipulations regarding the closeness to the gully. Mr. Simmons stated we would
need to see results of soil and geotech testing to determine how far away you need to be from
the gully. Mr. Simmons stated we are not spending money on tests until we have a Variance. The
Applicant said she has not spent money on Engineers. She would like to be approved for the
Variance first.
Frank Lamia asked if the Applicant tried to get a different footprint that fits within the Setback
and doesn’t interfere with the gully. The Applicant said the placement of this plan should be
within the setback.
Mr. Vira asked if the Applicant pushed the house back would she need a Variance. Mr. Rogers
said the house would be pushed into the gully. A smaller floor plan would be necessary to adhere
to the forty (40) foot required Setback.
Mr. Lamia asked again if the Applicant could find another footprint that would fit the required
Setback. The Applicant said she has been looking and has not found a one story to fit.
Mr. Simmons asked if there are size requirements in the neighborhood. The Applicant said a one-
story minimum is 2200 square feet, and a two-story minimum is 1200 square feet on the first
floor.
Chairman Vira opened the public hearing at 5:22.
Jerald Harshberger, 9 Greenbriar Lane, Fairhope, AL 36532: Mr. Harshberger stated his lot is
directly north of the lot being discussed. There are significant restrictions within our
Homeowners and Covenants, and garages are not allowed to be seen from the street. That would
bring the driveway closer to my property. There are trees there that have been growing for thirty
(30) years and are now encroaching on the property line where her driveway would need to be.
Secondly, the gully is partly on his property. Fifteen years ago, Mr. Harshberger planted ground
cover to preserve the soil. There are water oaks leaning into the gully, and some have already
fallen in. Putting a house this size will encroach on the sensitive gully edge and you will lose trees.
Page 3 of 63
Fairhope Board of Adjustment Minutes – February 23, 2026 3
The gully will get bigger and if it extends to his property, it exposes another issue. He is
disappointed that the lot was sold.
Leroy Sloan, 20 Greenbrier Lane, Fairhope, AL 36532: Mr. Sloan stated his concern is the house
being built may not fit into the neighborhood. It is Mr. Sloan’s opinion that de-treeing the lot will
lose three (3) to five (5) feet of the gully. The gully is much wider, deeper, and more severe than it
looks in the diagram. Mr. Sloan’s suggestion would be to build a bridge across the gully and build
on the backside of the lot or fill in the gully.
Mr. Vira asked if you could fill in the gully. Mr. Simmons stated it is very unlikely and we would
need studies done to find out.
Mr. Vira stated that this would also affect adjoining properties.
Mr. Simmons stated before anything else could be discussed, we would need an Engineer to look
at the property and that would be expensive.
Mr. Baker asked if the city has regulations to require a drainage study, and specific Ordinances
to prevent anyone from filling in a gully. Mr. Simmons said no, but they are working on a Steep
Slope Ordinance. The gullies are determined by FEMA and have federal guidelines.
Chairman Vira asks if anyone else from the public would like to speak.
David Tacon 415 Fairwood Blvd., Fairhope, AL 36532: Mr. Tacon has a piece of property on Ashley
Drive which is on this same gully. He supports Miss Rice’s application. There are multiple homes
built on Fairwood Drive that are on a gully and have no problems. Mr. Tacon stated that a
Variance on the gully has been approved before.
The Applicant asked why removing trees close to the gully would make the gully bigger. Mr. Sloan
answered because of the erosion. Mr. Baker also stated the roots are holding the soil in place.
The Applicant stated she would remove as few trees as possible.
Chairman Vira closed the public hearing at 5:35.
Mr. Vira asked Board members if there was any further discussion.
Donna Cook asked what the Setbacks are next door. Mr. Rogers stated the property should be
compliant with the standard 40-foot front yard Setback.
Mr. Vira asked about a nearby property that had a Variance approved. Mr. Rogers said it is lot 1
of Greenbriar, which is southeast to the subject lot. It is on 95 Blue Island Avenue and it was
approved for a 15-foot front yard Setback Variance.
Mr. Baker stated he did not understand why Staff cannot recommend approval. Mr. Simmons
stated the closeness to gully is the concern.
Mr. Baker said the gully is creating a new drainage easement which creates property loss. Isn’t it
technically a hardship based on topography? Mr. Simmons stated if the plan had more room
Page 4 of 63
Fairhope Board of Adjustment Minutes – February 23, 2026 4
away from the edge of the gully, we would be more supportive. A different plan would work, so it
is not a hardship.
Mr. Baker asked for clarification regarding sliding the house forward, creating separation from
the gully. Mr. Simmons replied that we can’t say how close you can be to the gully without a
geotech study.
Mr. Lamia asked if this is looked at during the building permit process. Mr. Simmons said yes, it
is. A new topographical survey would also need done. Mr. Lamia stated the gully might not be
where the photo shows it is.
Mr. Vira asked how far away we need to be from the gully. Mr. Simmons and Mr. Rogers both
stated they don’t have the expertise to answer that question.
Mr. Rogers said the Board could recommend approval on condition that an Engineer would
certify a safety standard. But we need a geotech report for that answer.
Mr. Vira asks if the Board can table this. Mr. Simmons says yes and you can ask the Applicant to
have reports done to see how close you can get to the gully.
Mr. Vira and Mr. Lamia discussed the cost of surveys and geotech reports, and Mr. Baker
estimated the cost to be a few thousand dollars. Mr. Vira asked if the Applicant would need this
for the building process. Mr. Simmons said yes.
Mr. Baker asked if Fairhope has any Ordinances that require a topography or geotechnical
studies. Mr. Simmons said yes, when warranted.
Mr. Simmons stated that without additional reports, we can’t answer questions regarding
closeness to the gully, and that is why we must recommend denial. This is a critical piece of
information that we need before providing an answer. Mr. Baker agreed.
Ms. Slagle asked if the Variance is denied, can the Applicant find a footprint that would fit in the
40-foot Setback and come back. Mr. Baker said that if the Variance is denied, the Applicant can’t
return for a year. There was a long discussion on what time frame was allowed. Mr. Rogers said
he will check on resubmission.
Ms. Cook asked if you could ask for seven (7) feet administratively. Mr. Simmons stated only to
save trees.
Mr. Rogers said limitations on resubmission from Article II, Section C states that an application
for the same parcel of land shall not be submitted within 365 days of final decision of the Board.
Any application may be withdrawn without prejudice prior to the opening of the hearing by the
Board. A request to withdraw an application shall be submitted to the Director in writing.
Mr. Rogers said if the Variance is denied, the Applicant cannot return with another request for
365 days. And for the record, if you choose to table it, please provide a specific number of months
to come back, and provide an end date for us.
Page 5 of 63
Fairhope Board of Adjustment Minutes – February 23, 2026 5
The Applicant said if she could be approved for a 15-foot Variance she will change her floor plan.
The Applicant asked if the main reason for the meeting is the Variance or is it everything. Mr.
Rogers stated it is the 15-foot front yard Variance, but it will affect your floor plan. The Applicant
said she will work on the floor plan.
Mr. Lamia asked if her plan could change to stay within the 40-foot front yard Setback. The
Applicant said no, she doesn’t think so.
Mr. Simmons stated that we can’t grant a Variance just to have a one-story home.
Mr. Rogers asked the Applicant if her surveyor performed this survey. The Applicant stated that
it was an old survey. Patrick, an Engineer, Architect placed the house and was going to build on
the lot. Mr. Rogers stated we don’t know where the topography came from.
The Applicant understands that you can’t grant a Variance without having more information.
Ryan Baker made a motion to Table BOA 26.01 for up to six (6) months with Staff
recommendations.
1. Provision of a topographical survey illustrating current topography as well as the top of
bank for the existing gully on site; and
2. Provision of geo-technical reporting for the subject site detailing an appropriate distance
(if any) from the top of bluff that a proposed dwelling would need to be located.
Anil Vira seconded the motion and the motion carried unanimously with the following vote:
AYE: Anil Vira, Donna Cook, Frank Lamia, Ryan Baker and Cathy Slagle.
NAY: None
ABSTAIN: None
ADJOURNMENT
Ryan Baker made a motion to adjourn.
The motion carried unanimously with the following vote:
AYE: Anil Vira, Donna Cook, Frank Lamia, Ryan Baker and Cathy Slagle.
NAY: None
ABSTAIN: None
Adjourned at 6:06 p.m.
________________________________ _________________________________
Anil Vira, Chairman Hunter Simmons, Interim Secretary
Page 6 of 63
Payton Rogers
Page 7 of 63
BOA 26.03 – 210 Gayfer Court
April 21, 2026
Page 1 of 9
SUMMARY OF REQUEST
Public hearing to consider the request of the Owner, Lucinda Chappelle, for a Building Height Variance on
property zoned R-2, Medium Density Single-Family Residential District. The property is located at 210 Gayfer
Court and is 0.72± acres.
SITE HISTORY
There have been no other Board of Adjustment or Planning Commission applications associated with this site.
STAFF COMMENTS
The applicant requests a Building Height Variance to allow renovation of an existing single-family home with
a maximum building height exceeding limits set by the City of Fairhope Zoning Ordinance. The proposal
includes using an alternative method for measuring building height.
According to Article III.C. Table 3-2, structures in R-2 Medium Density Single-Family Residential Districts are
limited to 30 feet in height. Article IX defines building height measurement as , “the distance from a lot’s
average natural elevation to the roof's mean point”, a standard adopted in 2017.
The subject site, developed in 1970, currently has a one-story, 2,562± SF dwelling with a pool, deck, and
pergola. The applicant plans to expand it into a 1.5-story, 5,344± SF dwelling. It should be noted that prior to
1988 the city used a different building height definition detailed below:
Building, Height: The vertical distance measured from the average elevation of the proposed finished grade at
the front of the building to…the mean height between eaves and ridge for gable, hip and gambrel roofs.
The existing dwelling, built in compliance with height standards at the time of development in 1970, is a legal
non-conforming structure. Renovations or additions are subject to Article VII of the Zoning Ordinance, which
requires compliance with current regulations for all new work. Hence this application.
As previously mentioned, the current definition of Building Height requires that the topography for the entire
property be taken into consideration when determining where to begin measuring building height from. This is
an important distinction for the subject site because a large gulley is located within the rear 150± feet of the
property and ranges in depth from 5 feet at its bottom to 53 feet at top-of-bluff. Due to this substantial
elevation change, to enforce the current definition as written would require the applicant to begin measuring
their building height from the 23-foot contour line shown on the submitted topographical survey (see exhibit).
The applicant would then calculate their maximum building height by adding the 30 feet allowed by the R-2
zoning district. Doing so means that in order to remain compliant with current height standards the mean roof
height of any structure built on site cannot be any higher than 30 feet above the 23-foot contour line. Put
another way, the mean roof height of any structure cannot be taller than the 53-foot contour line also shown
on the topographical survey. It’s important to note that the entirety of the existing dwelling is above the 53-foot
contour line, making it legal non-conforming and therefore unable to be expanded upon through renovations
and/or additions.
Page 8 of 63
BOA 26.03 – 210 Gayfer Court
April 21, 2026
Page 2 of 9
Figure 1: Existing Site Plan Illustrating Current Building Height Contours
If the site were undeveloped, only about 16% would be buildable under current Building Height standards due
to the gulley. An applicant could either build above the "top -of-bluff" but below the 53-foot contour line or fill
the bluff to develop the lower third of the site; both options pose safety and environmental concerns.
The applicant's full narrative and justification is in the application packet. Since their initial submission, they
have revised their request: now, they propose measuring Building Height from the finished grade at the front
façade to the mean roof height.
Staff acknowledges that calculating Building Height on the subject site is challenging under current
standards. Furthermore, this challenge is not unique to this property. There are numerous developed lots
throughout the City which share some of the same characteristics as the subject site. Recognizing the need
for a permanent solution, the Planning Department has proposed an amendment to the Zoning Ordinance
addressing building height issues; this amendment is pending before the Planning Commission.
While a Variance may be necessary to address building height at this site, staff does not support adopting a
unique definition solely for this property. This approach could lead to further non-conformities with upcoming
Zoning Ordinance changes and complicate future site development. As an alternative to the request, staff
suggests keeping the current definition but changing the land on which the definition is applied; by allowing
Building Height to be measured beginning from the average natural elevation of the northern portion of the lot
above the top-of-bluff line illustrated on the submitted boundary survey.
If approved per staff recommendation, the 51-foot contour line would be considered the “new” average
natural elevation of the lot (see exhibit). The applicant would then be able to calculate their maximum building
height by adding the 30 feet allowed by the R-2 zoning district. Meaning that in order to remain compliant with
Building Height on the subject site the mean roof height of any structure cannot be any higher than 30 feet
above the 51-foot contour line shown on the submitted topographical survey. As such, if approved, the
addition proposed by the applicant in the submitted architectural plans would be compliant with building
height as defined by staff recommendation.
Page 9 of 63
BOA 26.03 – 210 Gayfer Court
April 21, 2026
Page 3 of 9
Figure 2: Building Height per Staff Recommendation
Citizen Comments
During the public comment period Staff received comments from one (1) couple who own property directly
adjacent to the subject site at 204 Gayfer Court. Their primary concern is the potential loss of sunlight shining
on their property due to any shadow that the proposed dwelling may cast.
It should be noted that there is an existing line of trees along the shared property line between the subject site
and 204 Gayfer Court which currently shields direct sunlight from being cast onto the citizens’ property (see
exhibits). Staff has not been provided with any information which may suggest the proposed building would
add to or detract from the amount of sunlight shining onto 204 Gayfer Court.
The aforementioned public comment can be found in their entirety within the application package.
Page 10 of 63
BOA 26.03 – 210 Gayfer Court
April 21, 2026
Page 4 of 9
VARIANCE CONSIDERATIONS
Standards of Review:
Variances are not intended to be granted frequently. The applicant must clearly show the Board that the request is due
to very unusual characteristics of the property and that it satisfies the variance standards. What constitutes extraordinary
and exceptional conditions and unnecessary hardship is a matter to be determined from the facts and circumstances of
each application.
Article II Section C.3.e(1) of the City of Fairhope Zoning Ordinance states that the Board of Adjustments may grant a
Variance if:
(a) There are extraordinary and exceptional conditions pertaining to the particular piece of property in question
because of its size, shape, or topography;
(b) The application of the ordinance to this particular piece of property would create an unnecessary hardship.
Personal financial hardship is not a justification for a variance;
(c) Such conditions are peculiar to the particular piece of property involved; and
(d) Relief, if granted, would not cause substantial detriment to the public good and impair the purpose and intent of
this ordinance; provided however, that no variance may be granted for a use of land or building or structure that
is prohibited by this ordinance.
CONCLUSION AND RECOMMENDATION
The Applicant has provided evidence of extraordinary and/or exceptional conditions which may create unnecessary
hardship on the land such that a Variance may be necessary for the reasonable use of the property. Applying the standard
requirements of the Zoning Ordinance to the subject site would create unnecessary hardships as the site cannot be
improved upon as is without the need for a Variance. Topographical challenges presented by this application are not
peculiar to subject site. If approved, the Variance request would not appear to cause substantial detriment to the public
good as it would allow development on a scale similar to what was allowed when the neighborhood was originally being
developed.
Staff acknowledges that calculating Building Height on the subject site is challenging under current standards.
Furthermore, this challenge is not unique to this property. There are numerous developed lots throughout the City which
share some of the same characteristics as the subject site. Recognizing the need for a permanent solution, the Planning
Department has proposed an amendment to the Zoning Ordinance addressing building height issues; this amendment
is pending before the Planning Commission.
While a Variance may be necessary to address building height at this site, staff does not support adopting a unique
definition solely for this property. This approach could lead to further non -conformities with upcoming Zoning Ordinance
changes and complicate future site development. As an alternative to the request, staff suggests keeping the current
definition but changing the land on which the definition is applied; by allowing Building Height to be measured beginning
from the average natural elevation of the northern portion of the lot above the top-of-bluff line illustrated on the
submitted boundary survey.
Recommendation:
Based on the preceding, Staff recommends DENIAL of the site-specific building height definition as proposed.
Instead, Staff recommends APPROVAL of a Building Height Variance to allow Building Height to be measured beginning
from the average natural elevation of the northern portion of the lot above the top-of-bluff line illustrated on the
submitted boundary survey.
Page 11 of 63
EXHIBITS BOA 26.03 – 210 Gayfer Court
April 21, 2026
Page 5 of 9
Existing Site Plan Illustrating Current Building Height Contours
Page 12 of 63
EXHIBITS BOA 26.03 – 210 Gayfer Court
April 21, 2026
Page 6 of 9
Proposed Site Plan Illustrating Building Height per Staff Recommendation
Page 13 of 63
EXHIBITS BOA 26.03 – 210 Gayfer Court
April 21, 2026
Page 7 of 9
Existing Dwelling Elevations
Page 14 of 63
EXHIBITS BOA 26.03 – 210 Gayfer Court
April 21, 2026
Page 8 of 9
Proposed Renovation Elevations
Page 15 of 63
EXHIBITS BOA 26.03 – 210 Gayfer Court
April 21, 2026
Page 9 of 9
Existing Shared Tree Line Between 210 & 204 Gayfer Court
Page 16 of 63
lucindachappelle@gmail.com
Page 17 of 63
Page 18 of 63
Page 19 of 63
ROADSIDE - NORTHERN EXISTING
FRONT ELEVATION - SCALE 1/4'' = 1'-0''
EXISTING 3/12 ROOF PITCH w/ 36'' O.H. @ EAVES
RIGHT/ EASTERN EXISTING EXTERIOR ELEVATION - SCALE 1/4'' = 1'-0''
EXISTING DECK TO POOL
AREA REMOVED FROM VIEWEXISTING UNDER
HOUSE ACCESS
REAR / SOUTHERN EXISTING EXTERIOR ELEVATION - SCALE 1/4'' = 1'-0''
LEFT / WESTERN EXISTING EXTERIOR ELEVATION - SALE 1/4'' = 1'-0''
46
'
-
1
1
"
12
'
-
0
"
39
'
-
0
"
61'-10"
61'-10"
15
'
-
8
"
11
'
-
1
1
"
EX
I
S
T
I
N
G
FI
R
E
P
L
A
C
E
EXISTING UTILITIES
TO BE RELOCATED
RELOCATE & REMOVE EXISTING A/C &
MECHANICALS TO ALLOW FOR NEW EXPANSION
REMOVE
EXISTING
ELEC PANEL
TO NEW
LOCATION
REMOVE EXISTING
FIREPLACE CHIMNEY
@EXTERIOR
st
e
p
s
t
o
g
r
a
d
e
EXISTING GARAGE
665 SF
EXISTING H/C AREAS
1860 SF
EXISTING DECK AREA
127 SF
EXISTING STRUCTURE AREAS PRIOR TO REMODELING - SCALE 3/16'' = 1'-0''
EXISTING STRUCTURE AREAS
==========================
1st FLOOR H/C AREA = 1860 SF
1st FLOOR FRONT PORCH DECK =127 SF
EXISTING GARAGE = 662 SF
==================================
TOTAL AREA = 2649 SF
PRINT DATES
FINAL PRINT - 12/09/25
DESIGN DRAWN BY
Kirk A. ThomasKirk A. ThomasKirk A. ThomasKirk A. Thomas
To
t
h
e
b
e
s
t
o
f
m
y
k
n
o
w
l
e
d
g
e
t
h
e
s
e
p
l
a
n
s
a
r
e
d
r
a
w
n
t
o
c
o
m
p
l
y
w
i
t
h
t
h
e
c
o
d
e
r
e
q
u
i
r
e
m
e
n
t
s
f
o
r
th
e
i
r
i
n
t
e
n
d
e
d
u
s
e
b
y
o
w
n
e
r
'
s
a
n
d
/
o
r
b
u
i
l
d
e
r
'
s
s
p
e
c
if
i
c
a
t
i
o
n
s
,
a
n
y
c
h
a
n
g
e
s
m
a
d
e
o
n
o
r
t
o
t
h
e
m
af
t
e
r
p
r
i
n
t
s
a
r
e
s
e
a
l
e
d
w
i
l
l
b
e
d
o
n
e
a
t
t
h
e
o
w
n
e
r
'
s
a
n
d
/
o
r
b
u
i
l
d
e
r
'
s
e
x
p
e
n
c
e
a
n
d
r
e
s
p
o
n
s
i
b
i
l
i
t
y
.
Th
e
c
o
n
t
r
a
c
t
o
r
s
h
a
l
l
v
e
r
i
f
y
a
l
l
d
i
m
e
n
s
i
o
n
s
a
n
d
e
n
c
l
os
e
d
d
e
t
a
i
l
d
r
a
w
i
n
g
s
.
R
e
f
e
r
I
n
s
t
a
l
l
a
t
i
o
n
o
f
a
l
l
ma
t
e
r
i
a
l
s
t
o
m
a
n
u
f
a
c
t
u
r
e
s
a
n
d
c
o
d
e
r
e
q
u
i
r
m
e
n
t
s
f
o
r
ea
c
h
i
t
e
m
s
a
t
t
a
c
h
m
e
n
t
t
o
t
h
e
s
t
r
u
c
t
u
r
e
re
q
u
a
r
d
l
e
s
s
o
f
d
e
t
a
i
l
s
h
o
w
n
.
D
e
t
a
i
l
s
a
r
e
n
o
t
s
p
e
c
i
fi
c
t
o
s
t
r
u
c
t
u
r
e
d
r
a
w
n
,
d
e
t
a
i
l
s
a
r
e
d
r
a
w
n
a
s
pe
r
s
p
e
c
t
i
v
e
c
u
t
a
w
a
y
v
i
e
w
s
a
n
d
i
n
n
o
w
a
y
s
h
o
w
m
a
t
e
r
i
al
i
t
e
m
s
a
s
f
i
n
i
s
h
e
d
i
n
s
t
a
l
l
e
d
re
p
r
e
s
e
n
t
a
t
i
o
n
.
k
.
a
.
t
.
D
e
s
i
g
n
s
I
n
c
.
i
s
n
o
t
l
i
a
b
l
e
f
or
e
r
r
o
r
s
b
a
s
e
d
u
p
o
n
p
e
r
s
o
n
a
l
i
n
t
e
r
p
r
e
t
a
t
i
o
n
of
a
n
y
d
e
t
a
i
l
,
t
e
x
t
i
t
e
m
,
o
r
s
y
m
b
o
l
u
s
e
d
i
n
t
h
e
c
r
e
at
i
o
n
o
f
t
h
e
s
e
d
o
c
u
m
e
n
t
s
.
W
h
i
l
e
e
v
e
r
y
e
f
f
o
r
t
ha
s
b
e
e
n
m
a
d
e
i
n
t
h
e
p
r
e
p
a
r
a
t
i
o
n
o
f
t
h
i
s
p
l
a
n
t
o
a
v
oi
d
m
i
s
t
a
k
e
s
,
t
h
e
m
a
k
e
r
c
a
n
n
o
t
g
u
a
r
a
n
t
e
e
ag
a
i
n
s
t
h
u
m
a
n
e
r
r
o
r
.
T
h
e
L
i
c
.
C
o
n
t
r
a
c
t
o
r
/
O
w
n
e
r
s
o
f
th
e
p
r
o
j
e
c
t
m
u
s
t
c
h
e
c
k
a
l
l
d
i
m
e
n
s
i
o
n
s
a
n
d
de
t
a
i
l
s
p
r
i
o
r
t
o
c
o
n
s
t
r
u
c
t
i
o
n
a
n
d
b
e
s
o
l
e
l
y
r
e
s
p
o
n
s
ib
l
e
u
p
o
n
i
s
s
u
e
d
p
e
r
m
i
t
.
A
l
l
i
n
f
o
r
m
a
t
i
o
n
co
n
t
a
i
n
e
d
w
i
t
h
i
n
t
h
e
s
e
p
l
a
n
s
i
s
s
u
b
j
e
c
t
t
o
c
h
a
n
g
e
b
as
e
o
n
c
o
d
e
r
e
q
u
i
r
e
m
e
n
t
s
a
n
d
p
e
r
m
i
t
t
i
n
g
ju
r
i
s
d
i
c
t
i
o
n
I
n
t
e
r
p
r
e
t
a
t
i
o
n
.
Page #Page #Page #Page #A 1.1A 1.1A 1.1A 1.1
PL
A
N
S
C
A
L
E
:
BA
S
E
@
1
/
4
"
=
1
'
-
0
'
'
U.
O
.
N
.
S
C
A
L
E
M
A
Y
V
A
R
Y
P
E
R
P
L
A
N
OR
P
E
R
D
E
T
A
I
L
(
N
O
T
S
P
E
C
I
F
I
C
)
Building Code: IRC2018
Design Wind Speed: 130 mph
ASD - ASCE 7-10
Design Wind Speed: 160 MPH
Ultimate - ASCE 7-16
Req. Glazing & Door Design
Pressures (DP's) 50 psf
All Doors and Glazing Installed
shall be Impact Rated
Flood Zone: FIRM - X
Finish Floor Elevation:
Min. 36'' A.CL.RW.
Mean Roof Height:
I,
L
a
r
r
y
M
.
O
l
i
v
e
r
,
P
.
E
.
,
L
i
c
e
n
s
e
N
o
.
1
2
6
7
8
Ce
r
t
i
f
y
t
h
a
t
t
h
e
s
t
r
u
c
t
u
r
a
l
p
o
r
t
i
o
n
s
o
f
t
h
i
s
se
t
o
f
c
o
n
s
t
r
u
c
t
i
o
n
d
o
c
u
m
e
n
t
s
h
a
v
e
b
e
e
n
re
v
i
e
w
e
d
u
n
d
e
r
m
y
r
e
s
p
o
n
s
i
b
l
e
c
h
a
r
g
e
,
de
s
i
n
a
t
e
d
b
y
d
e
s
i
g
n
,
t
o
c
o
m
p
l
y
w
i
t
h
t
h
e
en
g
i
n
e
e
r
i
n
g
r
e
q
u
i
r
e
m
e
n
t
s
o
f
t
h
e
In
t
e
r
n
a
t
i
o
n
a
l
R
e
s
i
d
e
n
t
i
a
l
B
u
i
l
d
i
n
g
C
o
d
e
,
20
1
8
L
a
t
e
s
t
E
d
i
t
i
o
n
@
1
3
0
/
1
6
0
-
m
p
h
3
se
c
g
u
s
t
w
i
n
d
l
o
a
d
r
a
t
i
n
g
.
La
r
r
y
M
.
O
l
i
v
e
r
E
n
t
e
r
p
r
i
s
e
s
I
n
c
.
72
2
8
O
a
k
b
r
i
a
r
D
r
i
v
e
S
o
u
t
h
Mo
b
i
l
e
,
A
L
.
3
6
6
1
9
PE
R
M
I
T
J
U
R
I
S
D
I
C
T
I
O
N
:
CI
T
Y
O
F
F
A
I
R
H
O
P
E
B.
F
.
E
.
:
1
2
'
'
A
.
C
L
.
R
W
FL
O
O
D
Z
O
N
E
:
"
X
"
CO
N
T
R
A
C
T
O
R
:
S
T
E
V
E
J
O
N
E
S
C
O
N
T
R
A
C
T
O
R
PR
O
J
E
C
T
:
R
E
M
O
D
E
L
S
I
N
G
L
E
F
A
M
I
L
Y
R
E
S
.
CL
I
E
N
T
:
L
U
C
I
N
D
A
&
C
H
I
P
C
H
A
P
P
E
L
L
E
LO
C
A
T
I
O
N
:
F
A
I
R
H
O
P
E
,
A
L
.
PH
Y
S
I
C
A
L
A
D
D
R
E
S
S
:
2
1
0
G
A
Y
F
E
R
C
T
.
Base Slab Elev: 24''' A.F.G. (Varies)
FINAL REVIEW - 12/04/25
PRELIM. REVIEW -09/16/25
PRELIM. REVIEW - 11/04/25
PRELIM. REVIEW - 10/07/25
PRELIM. REVIEW -09/17/25
Ex
i
s
t
i
n
g
S
t
r
u
c
t
u
r
e
E
l
e
v
a
t
i
o
n
s
&
Su
r
v
e
y
-
L
o
c
.
@
2
1
0
G
a
y
f
e
r
C
t
.
EXISTING AS IS SITE PLAN - N.T.S.
c
2
0
2
5
C
O
P
Y
R
I
G
H
T
B
Y
K
.
A
.
T
.
D
e
s
i
g
n
s
I
n
c
.
T
h
e
s
e
d
r
a
w
i
ng
s
a
r
e
N
O
T
T
O
B
E
re
p
r
o
d
u
c
e
d
o
r
c
o
p
i
e
d
i
n
a
n
y
f
o
r
m
w
h
a
t
s
o
e
v
e
r
w
i
t
h
o
u
t
t
h
e
w
r
i
t
t
e
n
pe
r
m
i
s
s
i
o
n
o
f
K
.
A
.
T
.
D
e
s
i
g
n
s
I
n
c
.
-
A
N
Y
D
U
P
L
I
C
A
T
I
O
N
I
S
P
R
O
H
I
B
I
T
E
D
A
N
D
PU
N
I
S
H
A
B
L
E
U
N
D
E
R
F
E
D
E
R
A
L
L
A
W
.
T
h
e
p
u
r
c
h
a
s
e
r
h
a
s
t
h
e
ri
g
h
t
t
o
O
N
E
US
E
f
o
r
p
e
r
m
i
t
t
i
n
g
p
u
r
p
o
s
e
s
,
a
n
y
f
u
t
u
r
e
u
s
e
o
f
t
h
e
pl
a
n
,
i
d
e
a
s
,
e
l
e
v
a
t
i
o
n
s
,
co
n
t
e
n
t
s
,
o
r
c
h
a
n
g
e
s
t
o
d
e
s
i
g
n
a
r
e
t
h
e
p
r
o
p
e
r
t
y
o
f
K
.
A
.
T
.
D
e
s
i
g
n
s
I
n
c
.
AN
D
M
U
S
T
B
E
A
U
T
H
O
R
I
Z
E
D
B
Y
K
.
A
.
T
.
D
e
s
i
g
n
s
I
n
c
.
A
N
Y
U
NA
T
H
O
R
I
Z
E
D
U
S
E
WI
L
L
B
E
P
U
N
I
S
H
A
B
L
E
U
N
D
E
R
F
E
D
E
R
A
L
C
O
P
Y
R
I
G
H
T
L
A
W
S
.
Page 20 of 63
EX
I
S
T
EXIST EXIST EXIST EXIST
EX
I
S
T
EX
I
S
T
EX
I
S
T
EX
I
S
T
EX
I
S
T
EXISTEXISTEXISTEXISTEXIST
D/W
D/W
REF
.
DIS
C
31'-0"
35'-4"
15
'
-
4
"
10
'
-
8
"
10
'
-
3
"
10
'
-
1
0
"
25'-8"19'-9"
18
'
-
8
"
38
'
-
9
"
2'
-
0
"
79
'
-
0
"
82'-0"
10
'
-
5
"
GA
Y
F
E
R
C
O
U
R
T
50
'
R
I
G
H
T
O
F
W
A
Y
P
A
V
E
D
S
T
R
E
E
T
BA
C
K
O
F
C
U
R
B
FOUND CONCRETE MONUMENT
TBM TOP ELEV 58.3
FLOOD ZONE "X SHADED"
FLOOD ZONE AE (EL) 11)
S 81* 20' E 27' +/- PLAT
FLOOD ZONE "X SHADED"
S 44* 05' E 82' +/- PLAT
FL
O
O
D
Z
O
N
E
"
X
"
112.3' +/-
150.8' +/-
SET RE-BAR & CAP
FOUND CRIMP TOP PIPE
TOP OF BLIFF
23' +/-
2' +/-
24
'
'
O
A
K
36
'
'
O
A
K
CH
A
I
N
L
I
N
K
F
E
N
C
E
LO
T
2
0
CHAIN LINK FENCE
WOOD FENCE
LOT 19
179.13' MSD
176.17' MSD
N 19* 13' 50'' E 330' CAL
S 19* 13' 50'' W 228.50' CALLOT 21
12
'
'
T
R
I
P
P
L
E
O
A
K
FOUND CONCRETE MONUMENT
AT
&
T
B
O
X
PH
O
N
E
P.
P
.
63
WA
T
E
R
ME
T
E
R
S
61
62
CONCRETE DRIVE
10
0
'
P
L
A
T
1
0
0
.
0
8
'
M
s
d
59
9'
'
O
A
K
58
57
60
59
6058
56
55
53
52
56
NE
W
F
E
N
C
E
ADJ. CONC DRIVE
59
53
54
55
NE
W
F
E
N
C
E
SI
D
E
S
E
T
B
A
C
K
TO
E
X
I
S
T
I
N
G
SI
D
E
S
E
T
B
A
C
K
TO
E
X
I
S
T
I
N
G
FRONT SETBACK TO EXISTING
FRONT SETBACK TO EXISTING
NE
W
C
O
N
S
T
R
U
C
T
I
O
N
S
T
R
U
C
T
U
R
E
AD
D
I
T
I
O
N
T
O
E
X
I
S
T
I
N
G
FI
R
S
T
F
L
O
O
R
@
3
2
2
2
.
0
S
F
SCALE 1'' = 20'-0''
FU
T
U
R
E
P
O
O
L
IN
S
T
A
L
L
E
D
B
Y
O
T
H
E
R
S
EXISTING
GARAGE
EXISTING
BEDROOM #2
EXISTING
CLOSET
EX
I
S
T
I
N
G
CL
O
S
E
T
DEMO EXISTING
CLOSET
EXISTING
PANTRY
EXISTING
BEDROOM #3
EXISTING
CLOSET
wc
EXISTING
BATH #2
EXISTING
SHWR
EXISTING SUNROOM FLOOR
- ROOF - WINDOWS - DOORS
& WALLS TO BE REMOVED
EXISTING DECK AREA TO BE REMOVED
BUILDER TO FORM UP AND REPLACE WITH
COVERED CONCRETE PORCH w/2 @ 10'' COLUMNS
13'-4"
25
'
-
3
"
23'-6"
11
'
-
1
1
"
26'-4"
20'-0"
3'-1"
15
'
-
8
"
26'-6"35'-4"
39
'
-
0
"
12
'
-
0
"
6'
-
0
"
46
'
-
1
1
"
10
'
-
1
"
14'-9"22'-2"24'-11"
14
'
-
1
"
13'-4"
17'-0"3'-0"
61'-10"
EX
I
S
T
I
N
G
FI
R
E
P
L
A
C
E
EX
I
S
T
I
N
G
U
T
I
L
I
T
I
E
S
TO
B
E
R
E
L
O
C
A
T
E
D
4'' STEP DN
RELOCATE & REMOVE EXISTING A/C &
MECHANICALS TO ALLOW FOR NEW EXPANSION
RE
M
O
V
E
E
X
I
S
T
I
N
G
E
L
E
C
PA
N
E
L
T
O
N
E
W
L
O
C
A
T
I
O
N
REMOVE EXISTING
FIREPLACE CHIMNEY
@EXTERIOR
REMOVE EXISTING WINDOWS
REMOVE DR
REMOVE
WALL
REMOVE
WALLS
EXISTING
BATH #1
ALL KITCHEN CABINETS, COUNTERS &
APPLIANCES TO BE REMOVED
REMOVE DR
RE-FRAME
& CLOSE
OPENING
REMOVE DR
REMOVE DRREMOVE SLIDING DR.
& FRAME UP OPENING
REMOVE EXISTING
WINDOW & WALL
UP AREA
REMOVE STAIRS
REMOVE
EXTERIOR STAIRS
EXISTING ROOF & CEILING JOIST
MATERIALS TO BE REMOVED FROM
STRUCTURE - BUILDER TO REPLACE ROOF
AND CEILING WITH NEW FRAMING
BUILDER TO FRAME NEW 24''
KNEE WALL ATOP OF EXISTING
WALL - SEE TYP. WALL DETAIL
BUILDER TO REMOVE INTERIOR CEILING SHEET
ROCK & INSULATION THRUOUGHT STRUCTURE -
TO BE REPLACED WITH NEW DURING REMODEL.
REMOVE WALL
RE
M
O
V
E
W
A
L
L
REMOVE WALL
REMOVE BRICK
REMOVE BRICK
RE
M
O
V
E
B
R
I
C
K
REMOVE
STAIRS
BUILDER TO REFER ALLL NEW REMODELING AREAS - SPECIFICATIONS
- FRAMING ETC... TO NEW ALL INCLUSIVE FLOOR PLAN.
EXISTING DEMOLITION FLOOR PLAN
SCALE 1/4''= 1'-0''
ALL INTERIOR & EXTERIOR DOORS WILL BE REMOVED AND REPLACE WTH NEW IMPACT RATED
DOORS WHERE NECESSARY - SEE DR. SCHEDULE
ALL EXTERIOR WINDOWS WILL BE REMOVED - RAISED TO NEW HEADER HEIGHTS AND
REPLACED WITH IMPACT RATED GLASS - SEE WINDOW SCHEDULE
EXISTING STRUCTURE AREAS
==========================
1st FLOOR H/C AREA = 1860 SF
1st FLOOR FRONT PORCH DECK =127 SF
EXISTING GARAGE = 662 SF
==================================
TOTAL AREA = 2649 SF
SITEWORK NOTES:
=================
(1) The contractor shall be responsible to stake out of the building and porches in relationship with the drawings and any required zoning setbacks.
(2) The contractor shall verify all existing conditions, property lines, easements, and setbacks prior to proceeding with excavation to avoid duplication of
efforts.
(3) The Contractor shall disconnect all existing utilities. The existing utilities shall be removed or reworked to the extent required to accommodate new
construction and as approved by local utilities representatives. Install new utilities and services as required for new house addition where shown on new
floor plan.
(4) Areas under the removed structure & footing shall be excavated to the minimum extent required.The current drawings shall be coordinated with the actual
existing site conditions, tree locations and removal of the existing structures. Any potential conflicts or discrepancies that may affect the house location or
any significant features shall be reported to the Designers, Engineer, and owner prior to construction.
(5) The general contractor shall coordinate and make adjustments as agreed upon at that time to all finish floor elevations with the designer, engineer and
owner at the time of building stakeout. Actual numbers of treads and risers or steps may vary from the number shown on the drawings based on actual field
conditions, builder to adjust as needed.
(6) The contractor shall coordinate their efforts and shall both be responsible for maintaining on-site drainage away from footing trenches and shall provide
positive slopes away from the house and drives. Under NO circumstances cause additional drainage or erosion or increase of sediment or runoff to the
existing ponds or adjacent properties. Provide temporary diversions as necessary.
(7) The contractor shall protect adjacent properties and all on-site vegetation and trees outside the building footprint from any harm or adverse conditions
related to construction activities during the entire time of construction. Trees & vegetation in the area of the building footprint shall be removed. If trees
occur in the area adjacent to new construction, their removal shall be approved by the owner.
(8) The contractor shall provide a fenced tree protection zone around significant trees remaining. The contractor shall provide erosion control means &
methods to prevent site erosion & shall direct groundwater in a natural flow direction to collector areas.
(9) The location of any existing and proposed site utilities and service entrances & routes shall be determined on-site with the owner prior to any work being
performed. Local utility representatives shall be informed and shall agree and approve all utility work being performed. Provide underground service to the
fullest extent possible as agreeable to the owners.
ROOFING NOTES:
===============
R1 Provide new metal type shingle roofing system thruought the entire roof area to replace existing. Provide new conventional
framed roof & ceiling joist areas over existing and new framed wall section, apply underlayment, flashing & roofing systems for a
complete water tight roof installation in accordance with applicable codes and the very highest standard of care and recommended
installation procedures for a first class, thorough & complete job. Roofing shall meet the requirements for "Fortified Gold"
designation at a minimum. Refer to the NRCA Roofing & Waterproofing Manual (latest edition) for "best- practices" regarding
technical information & design & installation of roofing systems not specifically addressed in these drawings.
3'-0"
3'
-
0
"
3'-0"
3'
-
0
"
3'
-
0
"
3'-0"
3'-0"
3'
-
0
"
3'-0"
3'
-
0
"
EXISTING ROOF PLAN
SCALE 3/16'' = 1'-0''
3/12 ROOF PITCH EXISTING @ SITE
w/ 36'' OVER HANG @ EAVES
PORCH
REMOVE ENTIRE
FIREPLACE / CHIMNEY
& BASE SUPPORT.
BUILDER TO REMOVE ALL EXISTING ROOF FRAMING, CEILING JOIST
FRAMING, ROOF DECKING, AND ROOFING MATERIALS TO EXPOSE
INTERIOR STRUCTURE AS NECESSARY TO COMPLETE ADDITION OF
NEW ROOF LOCATIONS. BUILDER TO PROVIDE PROTECTION OF
INTERIOR AGAINST WEATHER CONDITIONS, WHEN EXPOSED TO
ELIMINATE DETERIORATION. BUILDER TO FOLLOW NEW ROOF &
CEILING JOIST FRAMING PLAN TO CORRDINATE WITH THE ADJUSTED
NEW REMODEL FLOOR PLAN BEARING WALLS LOCATIONS. NEW
ROOF AREA TO MEET GOLD FORTIFICATIONS REQUIREMENTS.
° EROSION AND SEDIMENTATION CONTROL NOTES *
********************************************************************
Silt Fencing – Silt Fencing should be installed and entrenched on frontages, and any sides or back of lots that have a slope.
Type A silt fencing is mandatory on all Single Family Residential, Commercial, and multi-family sites, as well as all sites located
in critical areas.
Construction Entrances – A rocked entry must be installed on the entry point, to help minimize vehicle tracking. Aggregate size
should be at least 1”.10’ X 20’ for residential (minimum). Limited traffic should be allowed on the site.
Inlet Protection – Any storm drain inlets located in front of or directly downhill of the construction site should be protected with
acceptable inlet protection (such as sock pipes or mulch wattles). Monitor inlet protection devices during rain events to insure
street flooding is not evident.
The silt fence or other appropriate form of erosion and sediment control will be installed and maintained around the site to
contain fill during construction.
ANY FILL OR DEBRIS DEPOSITED IN THE STREET SHALL BE REMOVED BY THE CONTRACTOR AS NECESSARY.
PRINT DATES
FINAL PRINT - 12/09/25
DESIGN DRAWN BY
Kirk A. ThomasKirk A. ThomasKirk A. ThomasKirk A. Thomas
To
t
h
e
b
e
s
t
o
f
m
y
k
n
o
w
l
e
d
g
e
t
h
e
s
e
p
l
a
n
s
a
r
e
d
r
a
w
n
t
o
c
o
m
p
l
y
w
i
t
h
t
h
e
c
o
d
e
r
e
q
u
i
r
e
m
e
n
t
s
f
o
r
th
e
i
r
i
n
t
e
n
d
e
d
u
s
e
b
y
o
w
n
e
r
'
s
a
n
d
/
o
r
b
u
i
l
d
e
r
'
s
s
p
e
c
if
i
c
a
t
i
o
n
s
,
a
n
y
c
h
a
n
g
e
s
m
a
d
e
o
n
o
r
t
o
t
h
e
m
af
t
e
r
p
r
i
n
t
s
a
r
e
s
e
a
l
e
d
w
i
l
l
b
e
d
o
n
e
a
t
t
h
e
o
w
n
e
r
'
s
a
n
d
/
o
r
b
u
i
l
d
e
r
'
s
e
x
p
e
n
c
e
a
n
d
r
e
s
p
o
n
s
i
b
i
l
i
t
y
.
Th
e
c
o
n
t
r
a
c
t
o
r
s
h
a
l
l
v
e
r
i
f
y
a
l
l
d
i
m
e
n
s
i
o
n
s
a
n
d
e
n
c
l
os
e
d
d
e
t
a
i
l
d
r
a
w
i
n
g
s
.
R
e
f
e
r
I
n
s
t
a
l
l
a
t
i
o
n
o
f
a
l
l
ma
t
e
r
i
a
l
s
t
o
m
a
n
u
f
a
c
t
u
r
e
s
a
n
d
c
o
d
e
r
e
q
u
i
r
m
e
n
t
s
f
o
r
ea
c
h
i
t
e
m
s
a
t
t
a
c
h
m
e
n
t
t
o
t
h
e
s
t
r
u
c
t
u
r
e
re
q
u
a
r
d
l
e
s
s
o
f
d
e
t
a
i
l
s
h
o
w
n
.
D
e
t
a
i
l
s
a
r
e
n
o
t
s
p
e
c
i
fi
c
t
o
s
t
r
u
c
t
u
r
e
d
r
a
w
n
,
d
e
t
a
i
l
s
a
r
e
d
r
a
w
n
a
s
pe
r
s
p
e
c
t
i
v
e
c
u
t
a
w
a
y
v
i
e
w
s
a
n
d
i
n
n
o
w
a
y
s
h
o
w
m
a
t
e
r
i
al
i
t
e
m
s
a
s
f
i
n
i
s
h
e
d
i
n
s
t
a
l
l
e
d
re
p
r
e
s
e
n
t
a
t
i
o
n
.
k
.
a
.
t
.
D
e
s
i
g
n
s
I
n
c
.
i
s
n
o
t
l
i
a
b
l
e
f
or
e
r
r
o
r
s
b
a
s
e
d
u
p
o
n
p
e
r
s
o
n
a
l
i
n
t
e
r
p
r
e
t
a
t
i
o
n
of
a
n
y
d
e
t
a
i
l
,
t
e
x
t
i
t
e
m
,
o
r
s
y
m
b
o
l
u
s
e
d
i
n
t
h
e
c
r
e
at
i
o
n
o
f
t
h
e
s
e
d
o
c
u
m
e
n
t
s
.
W
h
i
l
e
e
v
e
r
y
e
f
f
o
r
t
ha
s
b
e
e
n
m
a
d
e
i
n
t
h
e
p
r
e
p
a
r
a
t
i
o
n
o
f
t
h
i
s
p
l
a
n
t
o
a
v
oi
d
m
i
s
t
a
k
e
s
,
t
h
e
m
a
k
e
r
c
a
n
n
o
t
g
u
a
r
a
n
t
e
e
ag
a
i
n
s
t
h
u
m
a
n
e
r
r
o
r
.
T
h
e
L
i
c
.
C
o
n
t
r
a
c
t
o
r
/
O
w
n
e
r
s
o
f
th
e
p
r
o
j
e
c
t
m
u
s
t
c
h
e
c
k
a
l
l
d
i
m
e
n
s
i
o
n
s
a
n
d
de
t
a
i
l
s
p
r
i
o
r
t
o
c
o
n
s
t
r
u
c
t
i
o
n
a
n
d
b
e
s
o
l
e
l
y
r
e
s
p
o
n
s
ib
l
e
u
p
o
n
i
s
s
u
e
d
p
e
r
m
i
t
.
A
l
l
i
n
f
o
r
m
a
t
i
o
n
co
n
t
a
i
n
e
d
w
i
t
h
i
n
t
h
e
s
e
p
l
a
n
s
i
s
s
u
b
j
e
c
t
t
o
c
h
a
n
g
e
b
as
e
o
n
c
o
d
e
r
e
q
u
i
r
e
m
e
n
t
s
a
n
d
p
e
r
m
i
t
t
i
n
g
ju
r
i
s
d
i
c
t
i
o
n
I
n
t
e
r
p
r
e
t
a
t
i
o
n
.
Page #Page #Page #Page #A 1.2A 1.2A 1.2A 1.2
PL
A
N
S
C
A
L
E
:
BA
S
E
@
1
/
4
"
=
1
'
-
0
'
'
U.
O
.
N
.
S
C
A
L
E
M
A
Y
V
A
R
Y
P
E
R
P
L
A
N
OR
P
E
R
D
E
T
A
I
L
(
N
O
T
S
P
E
C
I
F
I
C
)
Building Code: IRC2018
Design Wind Speed: 130 mph
ASD - ASCE 7-10
Design Wind Speed: 160 MPH
Ultimate - ASCE 7-16
Req. Glazing & Door Design
Pressures (DP's) 50 psf
All Doors and Glazing Installed
shall be Impact Rated
Flood Zone: FIRM - X
Finish Floor Elevation:
Min. 36'' A.CL.RW.
Mean Roof Height:
I,
L
a
r
r
y
M
.
O
l
i
v
e
r
,
P
.
E
.
,
L
i
c
e
n
s
e
N
o
.
1
2
6
7
8
Ce
r
t
i
f
y
t
h
a
t
t
h
e
s
t
r
u
c
t
u
r
a
l
p
o
r
t
i
o
n
s
o
f
t
h
i
s
se
t
o
f
c
o
n
s
t
r
u
c
t
i
o
n
d
o
c
u
m
e
n
t
s
h
a
v
e
b
e
e
n
re
v
i
e
w
e
d
u
n
d
e
r
m
y
r
e
s
p
o
n
s
i
b
l
e
c
h
a
r
g
e
,
de
s
i
n
a
t
e
d
b
y
d
e
s
i
g
n
,
t
o
c
o
m
p
l
y
w
i
t
h
t
h
e
en
g
i
n
e
e
r
i
n
g
r
e
q
u
i
r
e
m
e
n
t
s
o
f
t
h
e
In
t
e
r
n
a
t
i
o
n
a
l
R
e
s
i
d
e
n
t
i
a
l
B
u
i
l
d
i
n
g
C
o
d
e
,
20
1
8
L
a
t
e
s
t
E
d
i
t
i
o
n
@
1
3
0
/
1
6
0
-
m
p
h
3
se
c
g
u
s
t
w
i
n
d
l
o
a
d
r
a
t
i
n
g
.
La
r
r
y
M
.
O
l
i
v
e
r
E
n
t
e
r
p
r
i
s
e
s
I
n
c
.
72
2
8
O
a
k
b
r
i
a
r
D
r
i
v
e
S
o
u
t
h
Mo
b
i
l
e
,
A
L
.
3
6
6
1
9
PE
R
M
I
T
J
U
R
I
S
D
I
C
T
I
O
N
:
CI
T
Y
O
F
F
A
I
R
H
O
P
E
B.
F
.
E
.
:
1
2
'
'
A
.
C
L
.
R
W
FL
O
O
D
Z
O
N
E
:
"
X
"
CO
N
T
R
A
C
T
O
R
:
S
T
E
V
E
J
O
N
E
S
C
O
N
T
R
A
C
T
O
R
PR
O
J
E
C
T
:
R
E
M
O
D
E
L
S
I
N
G
L
E
F
A
M
I
L
Y
R
E
S
.
CL
I
E
N
T
:
L
U
C
I
N
D
A
&
C
H
I
P
C
H
A
P
P
E
L
L
E
LO
C
A
T
I
O
N
:
F
A
I
R
H
O
P
E
,
A
L
.
PH
Y
S
I
C
A
L
A
D
D
R
E
S
S
:
2
1
0
G
A
Y
F
E
R
C
T
.
Base Slab Elev: 24''' A.F.G. (Varies)
FINAL REVIEW - 12/04/25
PRELIM. REVIEW -09/16/25
PRELIM. REVIEW - 11/04/25
PRELIM. REVIEW - 10/07/25
PRELIM. REVIEW -09/17/25
ARCHITECTURAL SITE PLAN - SCALE 1'-0'' =20'-0''
Ex
i
s
t
i
n
g
S
t
r
u
c
t
u
r
e
D
e
m
o
l
i
t
i
o
n
p
l
a
n
Ex
i
s
t
i
n
g
R
o
o
f
P
l
a
n
&
N
e
w
A
d
d
i
t
i
o
n
S
u
r
v
e
y
Pr
o
p
o
s
e
d
@
2
1
0
G
a
y
f
e
r
C
t
.
c
2
0
2
5
C
O
P
Y
R
I
G
H
T
B
Y
K
.
A
.
T
.
D
e
s
i
g
n
s
I
n
c
.
T
h
e
s
e
d
r
a
w
i
ng
s
a
r
e
N
O
T
T
O
B
E
re
p
r
o
d
u
c
e
d
o
r
c
o
p
i
e
d
i
n
a
n
y
f
o
r
m
w
h
a
t
s
o
e
v
e
r
w
i
t
h
o
u
t
t
h
e
w
r
i
t
t
e
n
pe
r
m
i
s
s
i
o
n
o
f
K
.
A
.
T
.
D
e
s
i
g
n
s
I
n
c
.
-
A
N
Y
D
U
P
L
I
C
A
T
I
O
N
I
S
P
R
O
H
I
B
I
T
E
D
A
N
D
PU
N
I
S
H
A
B
L
E
U
N
D
E
R
F
E
D
E
R
A
L
L
A
W
.
T
h
e
p
u
r
c
h
a
s
e
r
h
a
s
t
h
e
ri
g
h
t
t
o
O
N
E
US
E
f
o
r
p
e
r
m
i
t
t
i
n
g
p
u
r
p
o
s
e
s
,
a
n
y
f
u
t
u
r
e
u
s
e
o
f
t
h
e
pl
a
n
,
i
d
e
a
s
,
e
l
e
v
a
t
i
o
n
s
,
co
n
t
e
n
t
s
,
o
r
c
h
a
n
g
e
s
t
o
d
e
s
i
g
n
a
r
e
t
h
e
p
r
o
p
e
r
t
y
o
f
K
.
A
.
T
.
D
e
s
i
g
n
s
I
n
c
.
AN
D
M
U
S
T
B
E
A
U
T
H
O
R
I
Z
E
D
B
Y
K
.
A
.
T
.
D
e
s
i
g
n
s
I
n
c
.
A
N
Y
U
NA
T
H
O
R
I
Z
E
D
U
S
E
WI
L
L
B
E
P
U
N
I
S
H
A
B
L
E
U
N
D
E
R
F
E
D
E
R
A
L
C
O
P
Y
R
I
G
H
T
L
A
W
S
.
Page 21 of 63
COMMON AREAS
===============
FRONT COVERED PORCH = 133 SF
3 CAR GARAGE = 943 SF
REAR COVERED PORCH AREA = 645 SF
BASEMENT STORAGE AREA = 328 SF
==============================
TOTAL COMMON AREAS = 2049 SF
TOTAL AREA DESIGNED = 7286 SF
NEW REMODELED STRUCTURE AREAS
==========================
H/C FIRST FLOOR: 3772 SF
H/C SECOND FLOOR: 1465 SF
==========================
TOTAL H/C LIVING AREA = 5237 SF
12
8
12
8
1'
-
5
"
1'
-
4
"
10
'
-
1
"
1'
-
5
"
8'
-
1
"
22
'
-
1
1
"
2'
-
9
"
8'
-
1
"
2'
-
0
"
10
'
-
1
0
"
2'
-
0
"
2'
-
0
"
12
'
-
1
0
"
11
'
-
0
"
11
'
-
0
"
22
'
-
8
"
11
'
-
8
"
33
'
-
8
"
TOP OF
EXISTING
FOOTER
EXISTING
F.G.E.
EXISTING
F.F.E.
T.
O
.
P
.
O
F
B
E
A
M
F
R
O
M
S
L
A
B
T.O.R @
GABLE PEEKS
CLG. HGT @
2ND FLR.
F.F.E.
2ND FLR.
T.O.P.
1ST FLR.
T.O.P. @
EXISTING WALL
NEW CONST
KNEEWALL
HGT. T.O.96''
HDR HGT
96''
HDR HGT
96''
HDR HGT
4x4 CORBELS 4x4 CORBELS
F.F.E.
REMOVE/REPLACE EXISTING GARAGE
DRs. w/ NEW IMPACT RATED DRs.
IMPACT EGRESS
IMPACT FIXED
CRAFTSMAN
STYLE 6'' EXT TRIM
& LENTIL
HARDIE B&B VENEER
HARDIE B&B
VENEER
IMPACT EGRESS IMPACT FIXEDIMPACT FIXED IMPACT EGRESS
2 PLY 1 7/8'' x 11.75'' LVL HEADER BEAM
BUILDER TO MATCH NEW BRICK
VENEER TO EXISTING - APPLY
OVER NEWLY FRAMED
KNEEWALL 2 FT. SECTION
BUILDER TO MATCH NEW BRICK
VENEER TO EXISTING - APPLY
AS VENEER @ NEWLY FRAMED
EXT. WALL SECTIONS
NEW SINGLE CAR
GARAGE ADDITION
T.O.P. @
EXISTING GARAGE
BRICK ROW LOCK ABOVE
AWNING ROOF AREA
6/12 PITCH w/ 36'' METAL PANEL FINISH
12
8
8
12
8
128
12
CRAFTSMAN TRIM @ GABLECRAFTSMAN TRIM @ GABLE
CRAFTSMAN
STYLE 6'' EXT TRIM
& LENTIL
CRAFTSMAN
STYLE 6'' EXT
TRIM &
LENTIL
CRAFTSMAN STYLE 6'' EXT TRIM & LINTIL
T.O.P. @ NEW 2 FT CONST
KNEEWALL HGT.
HGT. @
EAVES
T.O.R @
GABLE PEEKS
T.O.P. @
NEW GARAGE
CL
G
.
H
G
T
I
N
N
E
W
G
A
R
A
G
E
F.F.E.
MID ROOF HGT FROM F.F.E. @ NEW GARAGE
F.
F
.
E
L
E
V
T
O
E
A
V
E
H
G
T
.
ME
A
N
R
O
O
F
H
G
T
F
.
F
.
E
.
T
O
M
I
D
R
O
O
F
R
A
N
G
E
FINISHED GRADE ELEVATION BASED ON LOT
SLOPE SEE SURVEY FOR ADJUSTMENTS
HG
T
T
O
R
O
O
F
P
E
E
K
F
R
O
M
G
A
R
A
G
E
S
L
A
B
H
G
T
.
FRONT EXTERIOR ELEVATION - PLAN SCALE - 1/4'' = 1'-0''
MIXED EXTERIOR : ORIGINAL BRICK VENEER OVER EXISTING STRUCTURE w/ HARDIE B&B VEN. @ PORCH & GABLES OVER 2x4'' EXT. TYP. WALLS @ 16'' O.C. MAIN WALL HEIGHT @ EXT SHALL BE 10' -1'' HEIGHT w/ 5/8'' APA
RATED SHEAR WALL SHEATHING @ EXT. WALLS. HEADER HGTS @ 1ST FLR. WINDOWS - 96'', HDR HGT & EXT FRONT DOOR U.O.N. FOUNDATION SHALL BE MIXED 8'' & 16" x 16'' CMU BLK SUPPORT FOUNDATION WALL, BASED
ON GRADE ELEV AT SITE, w/24'' w X 16''d FOOTER w/ 3 #5 RE-BAR ON RISERS. INTERIOR WALLS SHALL BE 2x4" & 6'' STUDS, @ 16'' O.C. TYP. EXTERIOR BRICK TO REMAIN AS IS - DO A FINAL PRESSURE WASH OF EXISTING.
8/12 PITCH w/GALV. 26g 36'' METAL ROOFING PANELS OVER,
19/32'' APA RATED PLY WD ROOF SHEATHING, PEEL & STICK
WEATHER RESILIANT MEMBRANE , OVER MIXED RF FRAMING -
2x6'' & 8'' RAFTERS @ 16'' O.C. & 2X6'' & 8''CEILING JOIST @ 16''
O.C. TYP T.O - w/12" O.H. & 16'' O.H. A.F.E. BUILDER TO VENT
ROOF 1/300MIN - ROOF SHALL BE NAILED PER IRC. 2018 REQ.
BUILDER TO REMOVE ALL EXTING ROOFING MATERIALS & FRAMING TO RE
FRAME @ 8/12 ROOF PITCH TYP. T.O. - ALL EXISTING INTERIOR & EXTERIOR
WALLS SHALL HAVE A MIN 24'' KNEE WALL BUILT ATOP OF EXISTING w/
STRAPPING TO EXISTING STUD WALLS. FIN OUT w/ MATCHING BRICK.
12'' WD COL12'' WD COLEXISTING 2X8 FLR. JOIST @ 16'' O.C.
STRUCTURAL NOTES:
---------------------------------------
DESIGN LOADS
=============
1. BUILDING CODES
1.1 2018 INTERNATIONAL RESIDENTIAL CODE FOR ONE AND TWO-FAMILY DWELLINGS
1.2 MINIMUM DESIGN LOADS FOR BUILDING AND STRUCTURE, ASCE 7-16
2. ROOF LOADS:
2.1 DEAD LOADS 15 PSF
2.2 LIVE LOADS 20 PSF
3. FLOOR LOADING:
3.1 ATTIC DEAD LOAD 10 PSF
3.2 TYPICAL FLOOR DEAD LOAD 12 PSF
3.3 LIVE LOADS
3.3.1 ROOMS OTHER THAN SLEEPING ROOMS 40 PSF
3.3.2 SLEEPING ROOMS 30 PSF
3.3.3 STAIRS AND DECKS 40 PSF
3.3.4 BALCONIES 80 PSF
3.3.5 CART STORAGE 100 PSF
4. WINDLOAD DATA:
4.1 BASIC WIND SPEED (3 SEC GUST) 130/160 MPH
4.2 WIND IMPORTANCE FACTOR 1.00
4.3 EXPOSURE CATEGORY ( B )
4.4 BUILDING CATEGORY ( II )
===============================================
This Residential structure has been engineered to a minimum of 140/160 MPH, 3 second gust. Per IRC 2018 Req.
All fur-downs and/or concealed areas greater than 500 square feet must be draft-stopped.
Plywood or OSB must be used on the underside of any open porches prior to application of the siding or other covering.
Minimum of 1 hour resistive rated construction between tenant spaces, floor to ceiling-ceiling to roof@ garage wall separation by no less than 1/2'' Gypsum board. Garage ceiling shall
also be finished @ no less than 1/2'' gypsum board for a min 1 hr rating..Doors shall have a min. 20 min rating. (Garage Area to Residential living space)
All walls with plumbing vent and drainage lines must be 2”x6” to meet IRC 2018 cutting and notching requirements.
Exterior Finished Veneer shall be no less thsn 6' above the finished graded lot elevation, and placed so as not to be Covered or concealed by any landscaping that may be done.
===============================================
1. ALL HEADERS AT EXT. WALLS SHALL BE WITHIN 2018 HEADER TABLE REQ. w/ 1/2" PLYWD FLITCH PLT. U.N.O. USE CODE REQ. TO DETERMINE SIZE APPROPRIATE WITH
OPENINGS
2. TRIPLE STUDS AT ALL OPENINGS LARGER THAN 6'-0". ALL BEAM BEARING SUPPORT ENDS (Note: Window & Door Strapping detail.)
3. BUILDER SHALL PROVIDE STRONGBACK TO ALL CONVENTIONAL FRAMED CEILING SPANS OVER 10'-0" .
4. BUILDER TO PROVIDE SOLID BLOCKING BETWEEN FLR. ALL OPEN WEB FLOOR JOIST, AND DECK JOIST AT MID SPAN. NO MORE THAN 48'' O.C. BLOCKING.
5. PROVIDE DBL. OPEN WEB FLOOR JOIST AT PARALLEL WALLS.
6. MANUFACTURED FLOOR/ ROOF TRUSSES WHEN USED SHALL BE DESIGNED FOR PROPER LOAD BEARING AND CERTIFIED BY A REGISTERED ENGINEER FROM THE TRUSS
MANUFACTURER.
INSTALL PER TRUSS LAYOUT & BRACE AT ALL BEARING POINTS REQ.BY MANUFACTURER.
7. HVAC CONTRACTOR SHALL PROVIDE LOAD CALCULATIONS AND COMPLETE DUCT LAYOUT AND DETAILS TO OWNER/CONTRACTOR PRIOR TO INSTALLATION.
8. CONTRACTOR SHALL VERIFY WITH OWNER THE SIZE, TYPE AND LOCATION OF ALL PLUMBING FIXTURES PRIOR TO CONSTRUCTION.
9. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR ENSURING THAT ALL WORK AND CONSTRUCTION MEETS OR EXCEEDS ALL CURRENT STATE , AND LOCAL CODES,
ORDINACES AND REGULATIONS, ETC.
10. THERE ARE NO WARRANTIES FOR A SPECIFIC USE EXPRESSED OR IMPLIED IN THE USE OF THESE PLANS.
11. STRUCTURE IS REQUIRED TO HAVE A FIRE SUPRESSION SYSTEM (SPRINKLER SYSTEM) INSTALLED PER IRC - 2018 SQ FT MIN. @ 5000 SF. BUILDER AND OWNER TO VERIFY
WITH INSPECTOR - AND LOCAL CODE REQUIREMENTS PRIOR TO PERMITTING. INSTALL PER MANUFACTURERS REQ. PER CODE ORDANANCE NUMBER OF HEADS PER ROOMS
OF REQ. PER SECTION 903.1 OF THE 2018 IRC REQUIREMENTS.
12. THE FINISHED FLOOR ELEV. OF ANY ENCLOSED AREA OR STAIRWELL MUST BE A MINIMUM OF ONE (1) FOOT ABOVE THE CENTERLINE OF THE ADJACENT STREET.
13. THE RIGHT OF WAY OF THIS PROPERTY MUST BE SODDED PRIOR TO ISSUANCE OF A CERTIFICATE OF OCCUPANCY.
=======================================================================
Additional requirements:
1. If this structure is located in a high corrosive zone. All directly exposed metal connectors must be stainless steel.
2. Where required on open sides of stairs or balconies, guards shall be minimum 36” in height per R311.7.8, R311.8.3, R311.7.8.3, R312.1.1 and intermediate rails shall not allow the
passage of a 4” diameter sphere per R312.1.3
3. In dwelling units, where the opening of an operable window is located more than 72” above the finished grade or surface below, the lowest part of the clear opening of the window
shall be a minimum 24” above the finished floor of the room in which the window is located.
Operable sections of windows shall not permit openings that allow passage of a 4” diameter sphere where such openings are located within 24” of the finished floor.(see exc. R312.2.1)
4. Every sleeping room shall have at least one operable emergency escape and rescue opening complying with IRC 2018 Section R310.2.1-R310.2.2 Clear net opening of 5.7 sq.ft. clear
opening having a minimum opening height of 24” and minimum opening width of 22” clear. To Comply to a min. of 24'' A.F.F. area to bottom of window sill.
5. Enclosed areas below design flood elevation must be used solely for parking, building access, or storage and be provided with flood openings to comply with R322.2.2.
6. Building materials used below the design flood elevation must be flood-resistant materials that
comply with R322.1.8.
7. Minimum R 15 insulation is required in walls, R 38 in ceiling.
8. IRC 2018 Section R311.7.3 requires a landing for 12’ of vertical rise on stairs.
9. A GFCI service outlet is required within 25’ of HVAC equipment per IRC 2018 E3901.12.
10. All exhaust must exit the structure completely.
11. Mechanical closets must be 12” larger than the unit installed and a minimum clearance of 3” on from the walls.
12. If the attic has storage located in it, a thermal barrier is required to separate the attic space from the foam insulation per IRC 2018 section R316.5.3 of the IRC.
10.0
CEILING
DEAD
LOAD
ANCHOR BOLTS
& STRAPS
CONTINUOUS
LOAD PATH
METHOD
3
BOTTOM
CHORD
DEAD LOAD
TOP CHORD
DEAD LOAD
DP50
DESIGN CODE REQ.
IRC -2018 - IBC 2018
40 /20
FLR.
SYSTEM
LIVE/DEAD
LOAD
3
FOR UPLIFT
CALS
1.0
IMPORTANCE
FACTOR
1 STORY RESIDENTIAL WOOD FRAME STRUCTURE
ON 4'' MONOLITHIC SLAB
130/160
3 Sec gust X
15.025.0 Per R301.5
IIB
ROOF
DEAD
LOAD
WIND
SPEED
(MPH)
FLOOD
ZONE
ATTIC
STORAGE
ROOF
LIVE
LOAD
WIND
EXPOSURE
BUILDING
CATEGORY
DESIGN
PRESSURE
RATING FOR
OPENINGS
GUST
EFFECT
FACTOR
0.85
STRUCTURE CRITERIA FOR DESIGN
SUBJECT TO DAMAGE FROM
CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA
32*
WINTER
DESIGN
TEMP
MEAN
ANNUAL
TEMP
AIR
FREEZING
INDEX
FLOOD
HAZARDS
ICE SHEILD
UNDER-
LAYMENT
REQUIRED
DECAYTERMITE
FROST
LINE
DEPTH
WEATHERING
SEISMIC
DESIGN
CATEGORY
WIND
SPEED
(MPH)
GROUND
SNOW
LOAD
FIRM 65*
0-1000 12" BFLNO
MOD. TO
SEVERE
ZERO
VERY
HEAVY0-A130/160 mph
3 sec gust
NEGLIGBLE
PRINT DATES
FINAL PRINT - 12/09/25
DESIGN DRAWN BY
Kirk A. ThomasKirk A. ThomasKirk A. ThomasKirk A. Thomas
To
t
h
e
b
e
s
t
o
f
m
y
k
n
o
w
l
e
d
g
e
t
h
e
s
e
p
l
a
n
s
a
r
e
d
r
a
w
n
t
o
c
o
m
p
l
y
w
i
t
h
t
h
e
c
o
d
e
r
e
q
u
i
r
e
m
e
n
t
s
f
o
r
th
e
i
r
i
n
t
e
n
d
e
d
u
s
e
b
y
o
w
n
e
r
'
s
a
n
d
/
o
r
b
u
i
l
d
e
r
'
s
s
p
e
c
if
i
c
a
t
i
o
n
s
,
a
n
y
c
h
a
n
g
e
s
m
a
d
e
o
n
o
r
t
o
t
h
e
m
af
t
e
r
p
r
i
n
t
s
a
r
e
s
e
a
l
e
d
w
i
l
l
b
e
d
o
n
e
a
t
t
h
e
o
w
n
e
r
'
s
a
n
d
/
o
r
b
u
i
l
d
e
r
'
s
e
x
p
e
n
c
e
a
n
d
r
e
s
p
o
n
s
i
b
i
l
i
t
y
.
Th
e
c
o
n
t
r
a
c
t
o
r
s
h
a
l
l
v
e
r
i
f
y
a
l
l
d
i
m
e
n
s
i
o
n
s
a
n
d
e
n
c
l
os
e
d
d
e
t
a
i
l
d
r
a
w
i
n
g
s
.
R
e
f
e
r
I
n
s
t
a
l
l
a
t
i
o
n
o
f
a
l
l
ma
t
e
r
i
a
l
s
t
o
m
a
n
u
f
a
c
t
u
r
e
s
a
n
d
c
o
d
e
r
e
q
u
i
r
m
e
n
t
s
f
o
r
ea
c
h
i
t
e
m
s
a
t
t
a
c
h
m
e
n
t
t
o
t
h
e
s
t
r
u
c
t
u
r
e
re
q
u
a
r
d
l
e
s
s
o
f
d
e
t
a
i
l
s
h
o
w
n
.
D
e
t
a
i
l
s
a
r
e
n
o
t
s
p
e
c
i
fi
c
t
o
s
t
r
u
c
t
u
r
e
d
r
a
w
n
,
d
e
t
a
i
l
s
a
r
e
d
r
a
w
n
a
s
pe
r
s
p
e
c
t
i
v
e
c
u
t
a
w
a
y
v
i
e
w
s
a
n
d
i
n
n
o
w
a
y
s
h
o
w
m
a
t
e
r
i
al
i
t
e
m
s
a
s
f
i
n
i
s
h
e
d
i
n
s
t
a
l
l
e
d
re
p
r
e
s
e
n
t
a
t
i
o
n
.
k
.
a
.
t
.
D
e
s
i
g
n
s
I
n
c
.
i
s
n
o
t
l
i
a
b
l
e
f
or
e
r
r
o
r
s
b
a
s
e
d
u
p
o
n
p
e
r
s
o
n
a
l
i
n
t
e
r
p
r
e
t
a
t
i
o
n
of
a
n
y
d
e
t
a
i
l
,
t
e
x
t
i
t
e
m
,
o
r
s
y
m
b
o
l
u
s
e
d
i
n
t
h
e
c
r
e
at
i
o
n
o
f
t
h
e
s
e
d
o
c
u
m
e
n
t
s
.
W
h
i
l
e
e
v
e
r
y
e
f
f
o
r
t
ha
s
b
e
e
n
m
a
d
e
i
n
t
h
e
p
r
e
p
a
r
a
t
i
o
n
o
f
t
h
i
s
p
l
a
n
t
o
a
v
oi
d
m
i
s
t
a
k
e
s
,
t
h
e
m
a
k
e
r
c
a
n
n
o
t
g
u
a
r
a
n
t
e
e
ag
a
i
n
s
t
h
u
m
a
n
e
r
r
o
r
.
T
h
e
L
i
c
.
C
o
n
t
r
a
c
t
o
r
/
O
w
n
e
r
s
o
f
th
e
p
r
o
j
e
c
t
m
u
s
t
c
h
e
c
k
a
l
l
d
i
m
e
n
s
i
o
n
s
a
n
d
de
t
a
i
l
s
p
r
i
o
r
t
o
c
o
n
s
t
r
u
c
t
i
o
n
a
n
d
b
e
s
o
l
e
l
y
r
e
s
p
o
n
s
ib
l
e
u
p
o
n
i
s
s
u
e
d
p
e
r
m
i
t
.
A
l
l
i
n
f
o
r
m
a
t
i
o
n
co
n
t
a
i
n
e
d
w
i
t
h
i
n
t
h
e
s
e
p
l
a
n
s
i
s
s
u
b
j
e
c
t
t
o
c
h
a
n
g
e
b
as
e
o
n
c
o
d
e
r
e
q
u
i
r
e
m
e
n
t
s
a
n
d
p
e
r
m
i
t
t
i
n
g
ju
r
i
s
d
i
c
t
i
o
n
I
n
t
e
r
p
r
e
t
a
t
i
o
n
.
Page #Page #Page #Page #A 1.3A 1.3A 1.3A 1.3
PL
A
N
S
C
A
L
E
:
BA
S
E
@
1
/
4
"
=
1
'
-
0
'
'
U.
O
.
N
.
S
C
A
L
E
M
A
Y
V
A
R
Y
P
E
R
P
L
A
N
OR
P
E
R
D
E
T
A
I
L
(
N
O
T
S
P
E
C
I
F
I
C
)
Building Code: IRC2018
Design Wind Speed: 130 mph
ASD - ASCE 7-10
Design Wind Speed: 160 MPH
Ultimate - ASCE 7-16
Req. Glazing & Door Design
Pressures (DP's) 50 psf
All Doors and Glazing Installed
shall be Impact Rated
Flood Zone: FIRM - X
Finish Floor Elevation:
Min. 36'' A.CL.RW.
Mean Roof Height:
I,
L
a
r
r
y
M
.
O
l
i
v
e
r
,
P
.
E
.
,
L
i
c
e
n
s
e
N
o
.
1
2
6
7
8
Ce
r
t
i
f
y
t
h
a
t
t
h
e
s
t
r
u
c
t
u
r
a
l
p
o
r
t
i
o
n
s
o
f
t
h
i
s
se
t
o
f
c
o
n
s
t
r
u
c
t
i
o
n
d
o
c
u
m
e
n
t
s
h
a
v
e
b
e
e
n
re
v
i
e
w
e
d
u
n
d
e
r
m
y
r
e
s
p
o
n
s
i
b
l
e
c
h
a
r
g
e
,
de
s
i
n
a
t
e
d
b
y
d
e
s
i
g
n
,
t
o
c
o
m
p
l
y
w
i
t
h
t
h
e
en
g
i
n
e
e
r
i
n
g
r
e
q
u
i
r
e
m
e
n
t
s
o
f
t
h
e
In
t
e
r
n
a
t
i
o
n
a
l
R
e
s
i
d
e
n
t
i
a
l
B
u
i
l
d
i
n
g
C
o
d
e
,
20
1
8
L
a
t
e
s
t
E
d
i
t
i
o
n
@
1
3
0
/
1
6
0
-
m
p
h
3
se
c
g
u
s
t
w
i
n
d
l
o
a
d
r
a
t
i
n
g
.
La
r
r
y
M
.
O
l
i
v
e
r
E
n
t
e
r
p
r
i
s
e
s
I
n
c
.
72
2
8
O
a
k
b
r
i
a
r
D
r
i
v
e
S
o
u
t
h
Mo
b
i
l
e
,
A
L
.
3
6
6
1
9
PE
R
M
I
T
J
U
R
I
S
D
I
C
T
I
O
N
:
CI
T
Y
O
F
F
A
I
R
H
O
P
E
B.
F
.
E
.
:
1
2
'
'
A
.
C
L
.
R
W
FL
O
O
D
Z
O
N
E
:
"
X
"
CO
N
T
R
A
C
T
O
R
:
S
T
E
V
E
J
O
N
E
S
C
O
N
T
R
A
C
T
O
R
PR
O
J
E
C
T
:
R
E
M
O
D
E
L
S
I
N
G
L
E
F
A
M
I
L
Y
R
E
S
.
CL
I
E
N
T
:
L
U
C
I
N
D
A
&
C
H
I
P
C
H
A
P
P
E
L
L
E
LO
C
A
T
I
O
N
:
F
A
I
R
H
O
P
E
,
A
L
.
PH
Y
S
I
C
A
L
A
D
D
R
E
S
S
:
2
1
0
G
A
Y
F
E
R
C
T
.
Base Slab Elev: 24''' A.F.G. (Varies)
FINAL REVIEW - 12/04/25
PRELIM. REVIEW -09/16/25
PRELIM. REVIEW - 11/04/25
PRELIM. REVIEW - 10/07/25
PRELIM. REVIEW -09/17/25
c
2
0
2
5
C
O
P
Y
R
I
G
H
T
B
Y
K
.
A
.
T
.
D
e
s
i
g
n
s
I
n
c
.
T
h
e
s
e
d
r
a
w
i
ng
s
a
r
e
N
O
T
T
O
B
E
re
p
r
o
d
u
c
e
d
o
r
c
o
p
i
e
d
i
n
a
n
y
f
o
r
m
w
h
a
t
s
o
e
v
e
r
w
i
t
h
o
u
t
t
h
e
w
r
i
t
t
e
n
pe
r
m
i
s
s
i
o
n
o
f
K
.
A
.
T
.
D
e
s
i
g
n
s
I
n
c
.
-
A
N
Y
D
U
P
L
I
C
A
T
I
O
N
I
S
P
R
O
H
I
B
I
T
E
D
A
N
D
PU
N
I
S
H
A
B
L
E
U
N
D
E
R
F
E
D
E
R
A
L
L
A
W
.
T
h
e
p
u
r
c
h
a
s
e
r
h
a
s
t
h
e
ri
g
h
t
t
o
O
N
E
US
E
f
o
r
p
e
r
m
i
t
t
i
n
g
p
u
r
p
o
s
e
s
,
a
n
y
f
u
t
u
r
e
u
s
e
o
f
t
h
e
pl
a
n
,
i
d
e
a
s
,
e
l
e
v
a
t
i
o
n
s
,
co
n
t
e
n
t
s
,
o
r
c
h
a
n
g
e
s
t
o
d
e
s
i
g
n
a
r
e
t
h
e
p
r
o
p
e
r
t
y
o
f
K
.
A
.
T
.
D
e
s
i
g
n
s
I
n
c
.
AN
D
M
U
S
T
B
E
A
U
T
H
O
R
I
Z
E
D
B
Y
K
.
A
.
T
.
D
e
s
i
g
n
s
I
n
c
.
A
N
Y
U
NA
T
H
O
R
I
Z
E
D
U
S
E
WI
L
L
B
E
P
U
N
I
S
H
A
B
L
E
U
N
D
E
R
F
E
D
E
R
A
L
C
O
P
Y
R
I
G
H
T
L
A
W
S
.
NE
W
R
E
M
O
D
E
L
E
X
T
E
R
I
O
R
E
L
E
V
A
T
I
O
N
S
w/
E
X
T
E
R
I
O
R
N
O
T
E
S
A
N
D
D
E
T
A
I
L
S
New Home Renovations to Existing Structure New Home Renovations to Existing Structure New Home Renovations to Existing Structure New Home Renovations to Existing Structure
for Lucinda & Chip Chappelle for Lucinda & Chip Chappelle for Lucinda & Chip Chappelle for Lucinda & Chip Chappelle
Located @ 210 Gayfer CourtLocated @ 210 Gayfer CourtLocated @ 210 Gayfer CourtLocated @ 210 Gayfer Court
Fairhope, Al. 36532Fairhope, Al. 36532Fairhope, Al. 36532Fairhope, Al. 36532
Page 22 of 63
GRADE
1'
-
4
"
2'-0"
FOOTERS MAY VARY: SEE
SEPERATE FOOTER DETAILS
ON FOUNDATION PAGE TO
MATCH SPECIFIC WALL
SUPPORT TYPES.
1 x 6'' BASE TRIM
1 @ #5 REBAR EVERY 48'' -
TURNED INTO SLAB MIN 25''4" 3000 psi
CONCRETE SLAB
2x4, 6'', PT SOLE PLATE w/ 5/8'' DIA
ANCHOR BOLT @ 24" O.C. w/ 3" SQ
WASHERS
1x WD WINDOW
STOOL & APRON
VINYL CLAD MIN. DPI 60 HW - IMPACT
RATED TYPE SH 1/1 WINDOW (REFER
TO FLOOR PLAN & ELEV. FOR
LOCATIONS, GRIDS & STYLE - ARCHES
- TRANSOMS)
6x6x10 W.W.M. w/ 6 MIL VAPOR
BARRIOR OVER CLEAN
COMPACTED CLAY FIL
INSULATION TYPE R- VALUE VARIES BASED
ON WALL THICKNESS (SEE PLAN LOC)
TYVECK HOUSE WRAP
EXT. FINISH: MIXED PAINTED BRICK
w/HARDIE B&B VENEER w/BATTENS
@12'' O.C. TYP. WHERE SHOWN ON
ELEVATIONS. APPLIED OVER 7/16"
WINDSTORM NORBOARD OR 5/8''
APA RATED EXT. SHEARWALL
SHEATHING - (EXTERIOR WALL
HEIGHT VARIES THROUGHOUT)
6'' Brick Ledge Poured w/
slab allow 1" air space
1/2" GYP. BD. ON WALL
# of Block's Vary based on
Grading & Slope MIN. 72''
+ 1 FHA 8'' header blk)
Poured Solid thru-out
1x WINDOW TRIM PAINTED
4'' & 6" WALL STUDS 16"
O.C.
R-21 INSULATION
VAPOR BARRIER
1/2" DRYWALL
IMPACT WINDOWS (SEE
PLAN) LOCAL CODE REQ.
DETAIL ONLY APPLIES
TO NEW STRUCTURE
CONSTRUCTION AREAS
(EXISTING AREA -
FOUNDATION AT SITE)
SEE ADDITIONAL EXT.
WALL DETAIL
MATCH BRICK VENEER
HOUSE WRAP (BUILDING PAPER)
1/2" EXTERIOR SHEATHING
4x6'' COLAR TIE
8'
-
1
'
'
BONUS LOFT
AREA
DBL. 6'' TOP PLATE (#2 SPRUCE OR
BETTER) W/ SIMPSON SP1 TO STUD
R-15
INSUL.
(TYP.)
16' O.H. w/
HARDIE VENTED
SOFFIT-CONT.
3/4" APA
RATED T&G
- GLUED &
SCREWED
5/8" GYP. BD. ON CLG.2x HEADER PER CODE
1/2" GYP.
BD. ON CLG.
R-_38___
INSULATION
TYVECK HOUSE WRAP
12
8
TYP. HARDIE FASCIA
w/GALV METAL EVE
DRIP EDGE ON 1X2 PT
FURRING STRIP, ON
FINISHED 2X6 SYP.
HURRICANE STRAPS (SEE ROOF FRAMING DETAILS)
OR 1" 16 g SIMPSON TWIST STRAP ROLL FROM TOP
PLATE TO BASE FOUNDATION OVER RAFTER TOP
METAL SHINGLE PANEL ROOF FIN. OVER SYNTHETIC
WEATHER RESILIANT MEMBRANE , OVER 2 x 6" & 8'' #2
RAFTERS @ 16" O.C. TYP - OVER 19/32" APA RATED
ROOF SHEATHING. NAILED PER IRC. 2018 REQ.
16'' OPEN WEB FLR JOIST @ 16'' O.C.
USE 2X8'' CEILING JOIST WHERE SHOWN
height
varies
2X4" #2
WALL
SUPPORT
8'-1 1/8"
CLG HGT.
10'-1 1/8"
CLG HGT.
1'-4"
F.F.E.
4" DRAIN TILE
12" GRAVEL FILL
12" X 24" CONT.
CONCRETE FOOTING
RE-BAR (3) #5 TYPICAL
THRU OUT
New Construction 1 1/2 Story Section w/8" & 16'' CMU Blk Stem wall,
w/ 2x6 framed wall above. NTS
WL
A-1
HGT VARIES @ REAR & SIDES
12
8
12
8
10
'
-
1
"
10
'
-
1
"
2'
-
1
0
"
8"
10
'
-
1
0
"
19
'
-
1
0
"
2'
-
0
"
12
'
-
1
0
"
6'
-
7
"
10
'
-
1
"
10
'
-
7
"
27'-3"
27
'
-
3
"
25
'
-
7
"
8'
-
6
"
4'
-
3
"
1'
-
0
"
8"
1'
-
0
"
8'
-
1
"
4"
4"
8"
6'
-
3
"
4"
6'
-
3
"
6'' CRAFTSMAN
STYLE TRIM &
LENTIL
4'' CONC SLAB @ PORCH AREA
8x16'' CMU SUPPORT
FOUNDATION WALL
w/ 12'' x 24'' FTR.
8x16'' CMU SUPPORT
FOUNDATION WALL
w/ 12'' x 24'' FTR.
8
12
8/12 PITCH w/GALV. 26g 36'' METAL ROOFING PANELS OVER,
19/32'' APA RATED PLY WD ROOF SHEATHING, PEEL & STICK
WEATHER RESILIANT MEMBRANE , OVER MIXED RF FRAMING -
2x6'' & 8'' RAFTERS @ 16'' O.C. & 2X6'' & 8'' CEILING JOIST @ 16''
O.C. TYP T.O - w/12" O.H. & 16'' O.H. A.F.E. BUILDER TO VENT
ROOF 1/300MIN - ROOF SHALL BE NAILED PER IRC. 2018 REQ.
BUILDER TO REMOVE ALL EXTING ROOFING MATERIALS & FRAMING TO RE
FRAME @ 8/12 ROOF PITCH TYP. T.O. - ALL EXISTING INTERIOR & EXTERIOR
WALLS SHALL HAVE A MIN 24'' KNEE WALL BUILT ATOP OF EXISTING w/
STRAPPING TO EXISTING STUD WALLS. FIN OUT w/ MATCHING BRICK.
BRICK TRIM @
DR.
6'' CRAFTSMAN
STYLE TRIM &
LENTIL
NEW GAS
METER
LOCATION
NEW RELOCATED ELECTRICAL
METER - POWER TO BE
UNDERGROUND TO NEW SERVICE
STAIRS TO GRADE BY BUILDER
BUILDER TO POUR THIS SECTION w/ 4'' CONC
SLAB FOR STORAGE AREA USE UNDER HSE.
CMU BASE (8'')
MAIN
HSE
F.F.E.
F.
F
.
E
.
T
O
T
O
P
O
F
F
T
R
-
HG
T
M
A
Y
V
A
R
Y
B
A
S
E
D
ON
F
I
N
.
G
R
A
D
E
@
S
I
T
E
36'' S.S. CABLE RAILING
12'' WD.
COLUMN
7' x 8' WOODEN
CARRIAGE DOORS
84''
Hdr Hgt
HEIGHT MAY
VARY BASED ON
SLOPE OF GRADE
F.F.E. @
BASEMENT
IMPACT OP/FIXED/OP
IMPACT
EGRESS
IMPACT
EGRESS
IMPACT FIXED
IMPACT FIXED
GABLE END
OPEN FRAMED END WALL
GB
4
GB
4
GABLE
END
GABLE
END
2x4'' FRAMED K.W. ATOP EXISTING
FIREPLACE /LIVING RM SECTION
6/12 PITCH
AWNING RF.
4x4
CORBELS
NEW
CONSTRUCTION
NEW
CONSTRUCTION
EXISTING FLR 2x8'' THIS AREA
FIN FLR ELEV @ EXISTING LIVING RM.
2x4'' FRAMED K.W. ATOP
EXISTING GARAGE WALL
10'
T.O. BEAM
10' 1 1/8''
T.O.P.
TANKLESS
H20
A/C
FINISHED SLAB ELEV @
BASEMENT STORAGE
EXISTING EXT.
STRUCTURE
EXISTING EXT.
STRUCTURE
96''
Hdr Hgt
96''
Hdr Hgt
96''
Hdr Hgt
96''
Hdr Hgt
36''
Rail Hgt.
NEW FLR 2x12'' JOIST THIS AREANEW FLR 2x12'' JOIST THIS AREA
NEW
CONSTRUCTION
EXISTING EXT.
STRUCTURE
NEW
CONSTRUCTION
EXISTING EXT.
STRUCTURE
12
8
12
8
3'
-
5
"
2'
-
0
"
8'
-
6
"
4'
-
3
"
25
'
-
7
"
27
'
-
1
"
6'
-
1
"
10
'
-
5
"
10
'
-
7
"
12
'
-
1
0
"
10
'
-
1
0
"
8'
-
1
"
10
'
-
1
"
2'
-
9
"
8"8"
2'
-
1
"
8"
6'
-
5
"
10
'
-
1
"
2'
-
9
"
1'
-
5
"
6'
-
1
"
4"
36''
Rail Hgt.
96''
Hdr Hgt
96''
Hdr Hgt
96''
Hdr Hgt
10' 1 1/8''
T.O.P.
10' -5''
T.O. BEAM
FIN FLR ELEV @ EXISTING STRUCTURE
EXISTING FLR 2x8'' THIS AREA
6/12 PITCH
AWNING RF.
GABLE
END
GABLE
END
GB
4
GB
4
GABLE END
OPEN FRAMED END WALL
IMPACT
EGRESSIMPACT FIXED
HEIGHT MAY VARY BASED ON SLOPE OF GRADE
12'' WD.
COLUMN
F.
F
.
E
.
T
O
T
O
P
O
F
F
T
R
-
HG
T
M
A
Y
V
A
R
Y
B
A
S
E
D
ON
F
I
N
.
G
R
A
D
E
@
S
I
T
E
MAIN
HSE
F.F.E.
BUILDER TO REMOVE ALL EXTING ROOFING MATERIALS & FRAMING TO RE
FRAME @ 8/12 ROOF PITCH TYP. T.O. - ALL EXISTING INTERIOR & EXTERIOR
WALLS SHALL HAVE A MIN 24'' KNEE WALL BUILT ATOP OF EXISTING w/
STRAPPING TO EXISTING STUD WALLS. FIN OUT w/ MATCHING BRICK.8/12 PITCH w/GALV. 26g 36'' METAL ROOFING PANELS OVER,
19/32'' APA RATED PLY WD ROOF SHEATHING, PEEL & STICK
WEATHER RESILIANT MEMBRANE , OVER MIXED RF FRAMING -
2x6'' & 8'' RAFTERS @ 16'' O.C. & 2X6' & 8'' CEILING JOIST @ 16''
O.C. TYP T.O - w/12" O.H. & 16'' O.H. A.F.E. BUILDER TO VENT
ROOF 1/300MIN - ROOF SHALL BE NAILED PER IRC. 2018 REQ.
12
8
12
8
12
8
STAIRS TO GRADE BY BUILDER
NEW CONSTRUCTION 8x16'' CMU SUPPORT
FOUNDATION WALL w/ 12'' x 24'' FTR.
4x4
CORBELS
2x4'' FRAMED K.W. ATOP EXISTING BEDROOMS /BATHROOM &
GARAGE EXTERIOR WALL SECTIONS
6'' CRAFTSMAN
STYLE TRIM &
LENTIL
6'' CRAFTSMAN
STYLE TRIM &
LENTIL
IMPACT
EGRESS
EXISTING 8x16'' CMU SUPPORT FOUNDATION
WALL w/ 12'' x 24'' FTR.
IMPACT FIXED
IMPACT
FIXED
EX
I
S
T
I
N
G
H
G
T
.
FI
N
I
S
H
E
D
E
X
T
E
R
I
O
R
W
A
L
L
H
G
T
.
STAIRS TO GRADE BY BUILDER
EXISTING 8x16'' CMU SUPPORT FOUNDATION
WALL w/ 12'' x 24'' FTR.
A/C
TANKLESS H20
THIS AREA OF EXISTING FOUNDATION NOT TO BE DISTURBED
EXISTING FLR 2x8'' THIS AREA
FINISHED BRICK VENEER w/BUILDER
TO MATCH EXISTING BRICK
LOCATION OF 16'' OPEN WEB FLR JOIST @ 16'' O.C. TYP. FOR ATTIC FLOOR SYSTEM - UNDER ROOF
T.O.P. K.W. @ GABLE
6'' CORNER
TRIM
4'' STEP DN
TO PORCH
10' 1 1/8''
T.O.P.
SLOPE OF GRADE
4'' CONC SLAB FOUNDATION @ NEW CONST.
FLOOR AREAS (SEE FOUNDATION PL.)
GRADE
6'
-
2
"
New Construction 1 1/2 Story Section w/8" & 16'' CMU Blk Stem wall,
w/ 2x6 framed wall above. NTS
2" X 4" TREATED
BOTTOM PLATE
1 1/2" WALL STUDS 16" O.C. 1
1/2" RIGID INSULATION
VAPOR BARRIER @
BASEMENT STORAGE AREA
2" X 2" TOP PLATE
4" DRAIN TILE
12" GRAVEL FILL
12" X 24" CONT. CONCRETE FOOTING
RE-BAR (3) #5 TYPICAL THRU OUT
8" x 16 FULL CONCRETE BLOCK WHERE
SHOWN w/ #5 REBAR VERTICAL REINF @
48" O.C. w/ SOLID POURED CORE DAMP
PROOFING (TO GRADE)
2" X 8" TREATED SILL PLATE
1/2" ANCHOR BOLTS 4' O.C.
VAPOR BARRIER
4" GRAVEL BASE
4" CONCRETE FLOOR
w/ 6x6x10 WIRE MESH
@ BASEMNT STORAGE RM
1 3/8" X 16" RIM JOIST
1/2" EXTERIOR SHEATHINGRIM JOIST INSULATION
3/4" T & G PLYWOOD FLOORING
MATCH BRICK VENEER
HOUSE WRAP (BUILDING PAPER)
1/2" EXTERIOR SHEATHING
6" WALL STUDS 16" O.C.
R-21 INSULATION
VAPOR BARRIER
1/2" DRYWALL2" X 6" BOTTOM PLATE
IMPACT WINDOWS (SEE
PLAN) LOCAL CODE REQ.
HGT.
VARIES
1'-4"
F.F.E.
10'-1 1/8"
CLG HGT.
8'-1 1/8"
CLG HGT.
2X4" #2
WALL
SUPPORT
height
varies
16'' OPEN WEB FLR JOIST @ 16'' O.C.
USE 2X8'' CEILING JOIST WHERE SHOWN
METAL SHINGLE PANEL ROOF FIN. OVER SYNTHETIC
WEATHER RESILIANT MEMBRANE , OVER 2 x 6" & 8'' #2
RAFTERS @ 16" O.C. TYP - OVER 19/32'' APA RATED
ROOF SHEATHING. NAILED PER IRC. 2018 REQ.
HURRICANE STRAPS (SEE ROOF FRAMING DETAILS)
OR 1" 16 g SIMPSON TWIST STRAP ROLL FROM TOP
PLATE TO BASE FOUNDATION OVER RAFTER TOP
TYP. HARDIE FASCIA
w/GALV METAL EVE
DRIP EDGE ON 1X2 PT
FURRING STRIP, ON
FINISHED 2X6 SYP.
8
12
TYVECK HOUSE WRAP
R-_38___
INSULATION
1/2" GYP.
BD. ON CLG.
2x HEADER PER CODE5/8" GYP. BD. ON CLG.
3/4" APA
RATED T&G
- GLUED &
SCREWED 16' O.H. w/
HARDIE VENTED
SOFFIT-CONT.
R-15
INSUL.
(TYP.)
DBL. 6'' TOP PLATE (#2 SPRUCE OR
BETTER) W/ SIMPSON SP1 TO STUD
BONUS LOFT
AREA
DETAIL ONLY APPLIES TO NEW
STRUCTURE CONSTRUCTION
AREAS (EXISTING AREA -
FOUNDATION AT SITE) SEE
ADDITIONAL EXT. WALL DETAIL
12'' FLOOR JOIST@ 16"
O.C. TYP. OVER
BASEMENT STORAGE RM
8'
-
1
'
'
2x6'' COLAR TIE
16" x 16 FULL CONCRETE BLOCK WHERE
SHOWN w/ #5 REBAR VERTICAL REINF @
48" O.C. w/ SOLID POURED CORE DAMP
PROOFING (TO GRADE)
BA
S
E
M
E
N
T
-
S
T
O
R
A
G
E
RM
A
R
E
A
O
N
L
Y
WL
B-1
PRINT DATES
FINAL PRINT - 12/09/25
DESIGN DRAWN BY
Kirk A. ThomasKirk A. ThomasKirk A. ThomasKirk A. Thomas
To
t
h
e
b
e
s
t
o
f
m
y
k
n
o
w
l
e
d
g
e
t
h
e
s
e
p
l
a
n
s
a
r
e
d
r
a
w
n
t
o
c
o
m
p
l
y
w
i
t
h
t
h
e
c
o
d
e
r
e
q
u
i
r
e
m
e
n
t
s
f
o
r
th
e
i
r
i
n
t
e
n
d
e
d
u
s
e
b
y
o
w
n
e
r
'
s
a
n
d
/
o
r
b
u
i
l
d
e
r
'
s
s
p
e
c
if
i
c
a
t
i
o
n
s
,
a
n
y
c
h
a
n
g
e
s
m
a
d
e
o
n
o
r
t
o
t
h
e
m
af
t
e
r
p
r
i
n
t
s
a
r
e
s
e
a
l
e
d
w
i
l
l
b
e
d
o
n
e
a
t
t
h
e
o
w
n
e
r
'
s
a
n
d
/
o
r
b
u
i
l
d
e
r
'
s
e
x
p
e
n
c
e
a
n
d
r
e
s
p
o
n
s
i
b
i
l
i
t
y
.
Th
e
c
o
n
t
r
a
c
t
o
r
s
h
a
l
l
v
e
r
i
f
y
a
l
l
d
i
m
e
n
s
i
o
n
s
a
n
d
e
n
c
l
os
e
d
d
e
t
a
i
l
d
r
a
w
i
n
g
s
.
R
e
f
e
r
I
n
s
t
a
l
l
a
t
i
o
n
o
f
a
l
l
ma
t
e
r
i
a
l
s
t
o
m
a
n
u
f
a
c
t
u
r
e
s
a
n
d
c
o
d
e
r
e
q
u
i
r
m
e
n
t
s
f
o
r
ea
c
h
i
t
e
m
s
a
t
t
a
c
h
m
e
n
t
t
o
t
h
e
s
t
r
u
c
t
u
r
e
re
q
u
a
r
d
l
e
s
s
o
f
d
e
t
a
i
l
s
h
o
w
n
.
D
e
t
a
i
l
s
a
r
e
n
o
t
s
p
e
c
i
fi
c
t
o
s
t
r
u
c
t
u
r
e
d
r
a
w
n
,
d
e
t
a
i
l
s
a
r
e
d
r
a
w
n
a
s
pe
r
s
p
e
c
t
i
v
e
c
u
t
a
w
a
y
v
i
e
w
s
a
n
d
i
n
n
o
w
a
y
s
h
o
w
m
a
t
e
r
i
al
i
t
e
m
s
a
s
f
i
n
i
s
h
e
d
i
n
s
t
a
l
l
e
d
re
p
r
e
s
e
n
t
a
t
i
o
n
.
k
.
a
.
t
.
D
e
s
i
g
n
s
I
n
c
.
i
s
n
o
t
l
i
a
b
l
e
f
or
e
r
r
o
r
s
b
a
s
e
d
u
p
o
n
p
e
r
s
o
n
a
l
i
n
t
e
r
p
r
e
t
a
t
i
o
n
of
a
n
y
d
e
t
a
i
l
,
t
e
x
t
i
t
e
m
,
o
r
s
y
m
b
o
l
u
s
e
d
i
n
t
h
e
c
r
e
at
i
o
n
o
f
t
h
e
s
e
d
o
c
u
m
e
n
t
s
.
W
h
i
l
e
e
v
e
r
y
e
f
f
o
r
t
ha
s
b
e
e
n
m
a
d
e
i
n
t
h
e
p
r
e
p
a
r
a
t
i
o
n
o
f
t
h
i
s
p
l
a
n
t
o
a
v
oi
d
m
i
s
t
a
k
e
s
,
t
h
e
m
a
k
e
r
c
a
n
n
o
t
g
u
a
r
a
n
t
e
e
ag
a
i
n
s
t
h
u
m
a
n
e
r
r
o
r
.
T
h
e
L
i
c
.
C
o
n
t
r
a
c
t
o
r
/
O
w
n
e
r
s
o
f
th
e
p
r
o
j
e
c
t
m
u
s
t
c
h
e
c
k
a
l
l
d
i
m
e
n
s
i
o
n
s
a
n
d
de
t
a
i
l
s
p
r
i
o
r
t
o
c
o
n
s
t
r
u
c
t
i
o
n
a
n
d
b
e
s
o
l
e
l
y
r
e
s
p
o
n
s
ib
l
e
u
p
o
n
i
s
s
u
e
d
p
e
r
m
i
t
.
A
l
l
i
n
f
o
r
m
a
t
i
o
n
co
n
t
a
i
n
e
d
w
i
t
h
i
n
t
h
e
s
e
p
l
a
n
s
i
s
s
u
b
j
e
c
t
t
o
c
h
a
n
g
e
b
as
e
o
n
c
o
d
e
r
e
q
u
i
r
e
m
e
n
t
s
a
n
d
p
e
r
m
i
t
t
i
n
g
ju
r
i
s
d
i
c
t
i
o
n
I
n
t
e
r
p
r
e
t
a
t
i
o
n
.
Page #Page #Page #Page # A 1.4A 1.4A 1.4A 1.4
PL
A
N
S
C
A
L
E
:
BA
S
E
@
1
/
4
"
=
1
'
-
0
'
'
U.
O
.
N
.
S
C
A
L
E
M
A
Y
V
A
R
Y
P
E
R
P
L
A
N
OR
P
E
R
D
E
T
A
I
L
(
N
O
T
S
P
E
C
I
F
I
C
)
Building Code: IRC2018
Design Wind Speed: 130 mph
ASD - ASCE 7-10
Design Wind Speed: 160 MPH
Ultimate - ASCE 7-16
Req. Glazing & Door Design
Pressures (DP's) 50 psf
All Doors and Glazing Installed
shall be Impact Rated
Flood Zone: FIRM - X
Finish Floor Elevation:
Min. 36'' A.CL.RW.
Mean Roof Height:
I,
L
a
r
r
y
M
.
O
l
i
v
e
r
,
P
.
E
.
,
L
i
c
e
n
s
e
N
o
.
1
2
6
7
8
Ce
r
t
i
f
y
t
h
a
t
t
h
e
s
t
r
u
c
t
u
r
a
l
p
o
r
t
i
o
n
s
o
f
t
h
i
s
se
t
o
f
c
o
n
s
t
r
u
c
t
i
o
n
d
o
c
u
m
e
n
t
s
h
a
v
e
b
e
e
n
re
v
i
e
w
e
d
u
n
d
e
r
m
y
r
e
s
p
o
n
s
i
b
l
e
c
h
a
r
g
e
,
de
s
i
n
a
t
e
d
b
y
d
e
s
i
g
n
,
t
o
c
o
m
p
l
y
w
i
t
h
t
h
e
en
g
i
n
e
e
r
i
n
g
r
e
q
u
i
r
e
m
e
n
t
s
o
f
t
h
e
In
t
e
r
n
a
t
i
o
n
a
l
R
e
s
i
d
e
n
t
i
a
l
B
u
i
l
d
i
n
g
C
o
d
e
,
20
1
8
L
a
t
e
s
t
E
d
i
t
i
o
n
@
1
3
0
/
1
6
0
-
m
p
h
3
se
c
g
u
s
t
w
i
n
d
l
o
a
d
r
a
t
i
n
g
.
La
r
r
y
M
.
O
l
i
v
e
r
E
n
t
e
r
p
r
i
s
e
s
I
n
c
.
72
2
8
O
a
k
b
r
i
a
r
D
r
i
v
e
S
o
u
t
h
Mo
b
i
l
e
,
A
L
.
3
6
6
1
9
PE
R
M
I
T
J
U
R
I
S
D
I
C
T
I
O
N
:
CI
T
Y
O
F
F
A
I
R
H
O
P
E
B.
F
.
E
.
:
1
2
'
'
A
.
C
L
.
R
W
FL
O
O
D
Z
O
N
E
:
"
X
"
CO
N
T
R
A
C
T
O
R
:
S
T
E
V
E
J
O
N
E
S
C
O
N
T
R
A
C
T
O
R
PR
O
J
E
C
T
:
R
E
M
O
D
E
L
S
I
N
G
L
E
F
A
M
I
L
Y
R
E
S
.
CL
I
E
N
T
:
L
U
C
I
N
D
A
&
C
H
I
P
C
H
A
P
P
E
L
L
E
LO
C
A
T
I
O
N
:
F
A
I
R
H
O
P
E
,
A
L
.
PH
Y
S
I
C
A
L
A
D
D
R
E
S
S
:
2
1
0
G
A
Y
F
E
R
C
T
.
Base Slab Elev: 24''' A.F.G. (Varies)
FINAL REVIEW - 12/04/25
PRELIM. REVIEW -09/16/25
PRELIM. REVIEW - 11/04/25
PRELIM. REVIEW - 10/07/25
PRELIM. REVIEW -09/17/25
c
2
0
2
5
C
O
P
Y
R
I
G
H
T
B
Y
K
.
A
.
T
.
D
e
s
i
g
n
s
I
n
c
.
T
h
e
s
e
d
r
a
w
i
ng
s
a
r
e
N
O
T
T
O
B
E
re
p
r
o
d
u
c
e
d
o
r
c
o
p
i
e
d
i
n
a
n
y
f
o
r
m
w
h
a
t
s
o
e
v
e
r
w
i
t
h
o
u
t
t
h
e
w
r
i
t
t
e
n
pe
r
m
i
s
s
i
o
n
o
f
K
.
A
.
T
.
D
e
s
i
g
n
s
I
n
c
.
-
A
N
Y
D
U
P
L
I
C
A
T
I
O
N
I
S
P
R
O
H
I
B
I
T
E
D
A
N
D
PU
N
I
S
H
A
B
L
E
U
N
D
E
R
F
E
D
E
R
A
L
L
A
W
.
T
h
e
p
u
r
c
h
a
s
e
r
h
a
s
t
h
e
ri
g
h
t
t
o
O
N
E
US
E
f
o
r
p
e
r
m
i
t
t
i
n
g
p
u
r
p
o
s
e
s
,
a
n
y
f
u
t
u
r
e
u
s
e
o
f
t
h
e
pl
a
n
,
i
d
e
a
s
,
e
l
e
v
a
t
i
o
n
s
,
co
n
t
e
n
t
s
,
o
r
c
h
a
n
g
e
s
t
o
d
e
s
i
g
n
a
r
e
t
h
e
p
r
o
p
e
r
t
y
o
f
K
.
A
.
T
.
D
e
s
i
g
n
s
I
n
c
.
AN
D
M
U
S
T
B
E
A
U
T
H
O
R
I
Z
E
D
B
Y
K
.
A
.
T
.
D
e
s
i
g
n
s
I
n
c
.
A
N
Y
U
NA
T
H
O
R
I
Z
E
D
U
S
E
WI
L
L
B
E
P
U
N
I
S
H
A
B
L
E
U
N
D
E
R
F
E
D
E
R
A
L
C
O
P
Y
R
I
G
H
T
L
A
W
S
.
CO
N
T
I
N
U
E
D
R
E
M
O
D
E
L
E
X
T
E
R
I
O
R
EL
E
V
A
T
I
O
N
S
w
/
E
X
T
E
R
I
O
R
N
O
T
E
S
AN
D
S
T
R
U
C
T
U
R
A
L
D
E
T
A
I
L
S
RIGHTSIDE / EASTERN
ELEVATION - SCALE 1/4'' = 1'-0''
LEFTSIDE / WESTERN
ELEVATION - SCALE 1/4'' = 1'-0''
WL
A-1
WL
B-1
WL
A-1
WL
A-1
Page 23 of 63
GOLD FORTIFICATION REQUIREMENTS
ROOF
COVERING
MEETS FORTIFIED REQUIREMENTSSECTION
SHINGLE ATTACHMENT:
Shingle shall be Installed using 6 fastners required by the manufacturer for highwind fastning, which ever is greater. Attachment at eaves, rakes,
valleys, gable ends and starter strips. Shingles and starter strips at all intersections, eaves, valleys, and gable ends shall be set in a min. 8'' wide
strip of flashing cement. Maximum thickness of flashing cement shall be 1/8''. Shingles shall not extend more than 1/4''beyond the drip edge.
METAL PANELS:
Metal panel roofing systems and thier attachment shall be installed in accordance with the manufacturers Installation instructions and
shall provide uplife resistance equal to or greater than the designed uplife pressurefor this roof based on the site design, wind speed and
exposure catagory. The Metal Panels shall be installed over continuous decking and one of the acceptable sealed roof deck option.
1. Installation of a Peel & Stick membrane over the entire roof deck: The entire roof deck shall be covered with a full layer of self adhearing
polymer modified bitumen ("Peel & Stick") Meeting ASTM D1970 requirements. In applications where membrane adhesion to OSB is marginal,
apply a primer to the OSB panels to insure a propper attachment of the self - adhearing membrane to the sheathing. A bond break, such as a
15- pound ASTM D226 , Type - 1 underlayment, is to be installed between the "Peel & Stick" membrane and asphalt shingles, metal roof panel,
or other roof covering that would otherwise adhere to a degreethat future re-roofingwould be severly complicated.
SEALED
ROOF
DECKING
2. Installation of a minimum 4'' wide self - adhering polymer modified bitumen flashing "Peel & Stick" installed of all wood roof panel seams,
covered by compliant underlayment over entire roof. In applications where membrane adheasion to OSB is marginal, apply a primer apply a
primer to the OSB panels to ensure the proper attachment of the self - adhering membrane to the sheathing.
3. Installation of a high tear strength synthetic roof underlayment:
Application of a reinforced synthetic roof underlayment which has an ICC approval as an alternate to ASTM D226 Type 11 felt paper. The synthetic
underlayment must have minimum tear strength of 20 lbs. per ASTM D1970 or ASTM D4533. This underlayment must be attached using annular ring
or deformed shank roofing fastners center in the field or a more strengent fastner schedule if required by the manufacturer for high wind
installations. The minimum horizontal overlap between rolls is 2 inches and the minimum overlap at the ends of rolls is 6- inches. All underlayment
seams should be sealed with a compatable adhesive or tape provided the overlapfor horizontal seams is at least 18 inches. Vertical underlayment
seams should always be sealed.
ALUMINUM or
VINYL SOFFITS
Soffits to be covered with Aluminum or Vinyl shall first be sheathed with 7/16 OSB or Plywood connected to framing designed to resist ASCE 7-10
adjacent components and cladding wall pressures. The wall sheathing may be installed with a continuous vent gap up to 2 inches wide. Soffits in
the gable shall not be vented.
ROOF DECKING
ATTACHMENT
Roof decks shall be attached in accordance with the approved plans but no greater than 6 inches on center along panel edges and in the field for
zone 1 AND no greater than 4 inches on center along panel edges and in the field for zones 2 & 3 using minimum 8d (0.113" x 2-3/8'') irregular
shank (i.e. ring shank or spiral) nails with full round heads. Staples are not permitted for fastening of this roof decking. For definitions of zones 1.
2. & 3 refer to figure 207 (2) Roof Sheathing Nailing Zones in ICC 600-2008
ROOF
VENTILATION
Roof ventilation shall be designed for the applicable windload: ridge and off ridge vents shall be tested in accordancewith TAS 100 (A) for high wind and
be labled for verification of compliance. All roof ventilation shall be anchored in accordance with the manufacturer's installation instructions for the
appropriate wind load. Gable vents and power vents are not permitted. Vented soffits are not allowed along gable slopes. However if gable vents are
desired for Architectual purposes, they shall be non-functional, for decorative purposes only.
CHIMNEY
CHASES
Wood framed chimney chases shall be structurally connected to the roof and ceiling framing. The chimney chase
shalled be detailed in the approved plans and be designed to resist applicable loads specified in ASCE 7 - 10
YES
YES
YES
YES
NO
YES
YES
YES
NO
CONTINUOUS
LOAD PATH
Structure Meets the requirements for Roof to Wall Connection
Structure Meets the requirements for Wall to Floor Connection
Structure Meets the requirements for Floor to Foundation Connection
YES
WINDOW & DOOR
OPENINGS
Window & Door openings in all Exterior wall sections Meet the requirements to have adequate design pressure
ratings. (see Manufacturers label attached to installed units - not to be removed until after inspection) All window
& door units must meet Impact-protection with an approved system
YES
Structure Meets the requirements for Roof connected to beam to resist uplift
Structure Meets the requirements for Beam connected to column to resist uplift
Structure Meets the requirements for Column anchored to structure to resist uplift
PORCHES &
CARPORTS
Shall be Corrosion resistant Roof-mounted vents. Vents must be high-wind rated attached per manufacturers req.. All Soffit vents will resist water intrusion. Gable
overhangs and vents shall be properly braced as per req. - All Gables over 4' tall must be constructed as sheer walls with structural sheathing - Apply 7/16'' APA rated
Ply Wd each side - nailed @ 4'' o.c. typ. Gable end vents shall be protected against water intrusion.
YES
ATTIC
VENTILATION YES
A sealed roof deck is required for all new construction and re- roofing applications by one of the following methods.
Structural Requirements:
******************************
This Residential structure has been engineered to a minimum of 130/160 MPH, 3 second gust. Per IRC2018 Req.
All fur-downs and/or concealed areas greater than 500 square feet must be draft-stopped.
Plywood or OSB must be used on the underside of any open porches prior to application of the siding or other covering.
Minimum of 1 hour resistive rated construction between garage and Living area spaces.
All walls with plumbing vent and drainage lines must be 2”x6” to meet IRC 2018 cutting and notching requirements.
Weep holes in brickwork must be at least 1 course above finished floor elevation (FFE) and placed so as not to be covered or concealed by any landscaping
that may be done.
Roof Requirements:
************************
26g Galvalume Metal Roofing Panels shall be installed according to the manufacturer recommended listed installation instructions for High Wind areas
(130/160 mph ASTM E1592 Class 4 ) with #14 -10 x 1 1/2'' type A Hex Head w/separate 5/8 O.D. steel washer & bonded neoprene washer @ 3 ' - 0'' o.c. along
the length & 4 same type fastners across the middle adjacent to the rib.
Roof underlayment shall be installed per Manufacturer’s Installation Instructions but, shall not be fastened with staples.
Roof decking shall be nailed in accordance with the engineered drawings but no greater than 4 inches OC both edge and field within the 4 foot roof edge zone
and maximum 6 inches OC edge and field all other locations.
Decking shall be fastened with minimum 8d full round head ring shank nails. Staples will not be permitted.
Roof decking shall be “sealed”. All sheathing seams shall be taped with minimum 4 inch Peel and Stick tape meeting ASTM D1970, or spray polyurethane
closed cell foam adhesive (meeting ASTM D1622) shall be applied over all joints between sheathing and along all intersections between roof sheathing and all
roof framing members. Other equal or greater methods may be approved by the Building Official.
All aluminum and vinyl Soffit covering shall be attached to minimum 7/16 OSB or plywood or minimum 2 X 2 wood supports equally spaced but not greater
than 12 inches OC. if shown in plans as material of use.
Energy Code:
****************
Building cavities shall not be used as ducts or plenums.
Programmable thermostat shall be used where the primary system is a forced-air furnace.
All supply and return ducts not completely inside the building thermal envelope shall be insulated to a minimum of R-6.
Mechanical system piping (Freon line) capable of carrying fluids above 105ºF or below 55ºF shall be insulated to a minimum of R-3. Piping insulation shall be
protected from damage including environmental damage.
A minimum of 75% of lamps in permanently installed lights shall be of high efficacy.
All holes on interior and exterior wall top plates shall be sealed.
All holes and spaces around plumbing pipes, electrical, and mechanical penetrating interior or exterior wall top plates shall be sealed.
All wall windows must have a U factor of .40 and a SHGC of .25.
Attic insulation must be a minimum of R-38.
Wall insulation must be a minimum of R-13/15.
Floor insulation must be a minimum of R-19/21.
Plumbing Requirement:
****************************
Open trenches that show all fittings and slope of sewer and other in ground piping are required during rough-in inspections prior to pouring of slabs.
Topout inspections require that water be in all PVC piping to either the level of the washer/dryer box in single story houses, or at a height of 1’ above a sink
drain line at the top floor of multiple story buildings.
Use of in-line venting devices is not allowed in lieu of properly installed venting systems; any exception must be approved by the Building Department.
Schedule 40 pipe is required for all sewer lines from the building to the sewer.
Contractors cannot tie a sewer line directly into a manhole without first obtaining an inspection and permission from either the City Water and Sewer
Department or the Building Department. In addition the tie in must be core drilled so as to limit the amount of debris introduced into the sewer line and both
sides of the penetration must be grouted.
Donut Rings” (rubber gaskets) cannot be used to connect the building sewer line to the main in lieu of properly sized PVC fittings and reducers.
Septic tanks require a signed release from the Baldwin County Health Department.
Sewer lines and water supply lines running from the road to the house MUST HAVE either 5’ of horizontal separation or 12” of vertical separation if they are in
the same trench.
All slip joint fittings must have an access panel for servicing.
All Jacuzzi tubs must have an access panel large enough to reach and remove the motor.
All installations of Grinder Pumps require the master plumber of record to complete and sign the “Grinder Pump Installation” Form and submit to the Building
Department.
Mechanical Requirements:
********************************
Water heaters (both electric and gas) if located in garages that are in the direct path of the garage door must be protected by enclosure, elevation, bollards, or
some other reasonable measure to protect the unit from vehicle damage.
Blocking placed underneath the HVAC condenser to elevate it in the auxiliary pan must be compatible to material in contact with and of decay resistant
material (brick, plastic, etc).
HVAC equipment must be provided with an auxiliary float switch in the pan or on the unit that will stop the unit in the case of blockage of the primary drain
line.
Any HVAC equipment with internal float switches installed must have manufacturer’s information available for review by the Building Inspector and must
have a label stating the installation clearly visible.
Attic mounted mechanical equipment (HVAC, water heaters, etc.) shall not be mounted more than 20’ from the attic access point, shall have a clear walkway at
least 24” wide from the access to the equipment panel, and shall have a level working platform extending at least 30” from the edge of the equipment. Also
see energy and electrical supplements.
1'
-
5
"
8'
-
1
"
1'
-
1
"
8'
-
1
"
8'
-
9
"
6'
-
0
"
27
'
-
3
"
16
'
-
8
"
10
'
-
7
"
19
'
-
1
0
"
12'-7"
6'
-
3
"
4"
10
'
-
1
"
10
'
-
1
"
8'
-
1
"
1'
-
0
"
4"8"
9'
-
9
"
80''
Hdr Hgt
T.O.P.
10' 1 1/8''
T.O.P.
10' 1 1/8''
HARDIE B&B EXT VENEER
HARDIE B&B
EXT VENEER
3 PLY 1 7/8'' x 11.78'' LVL BEAM
F.F.E.
F.S.E.
8' -1'' CLG HGT
@ BASEMENT
BUILDER TO APPLY 1/2'' PLY WD
OVER INSULATED FLOOR
SYSTEM THROUGHOUT THE
BASEMENT CEILING AREA
STAIRS TO
GRADE
FROM
GARAGE
BUILDER TO POUR THIS SECTION w/ 4'' CONC
SLAB FOR STORAGE AREA USE UNDER HSE.
F.F.E. @
BASEMENT
CMU BASE (8'')
HEIGHT MAY VARY BASED ON SLOPE OF GRADE
96''
Hdr Hgt
96''
Hdr Hgt
GABLE END OPEN 4X6
PT POST FRAMED END
WALL UPRIGHTS
IMPACT EGRESS
6'' CRAFTSMAN
STYLE TRIM &
LENTIL
6'' CRAFTSMAN STYLE
TRIM & LENTIL
36'' S.S. CABLE RAILING
8/12 PITCH w/GALV. 26g 36'' METAL ROOFING PANELS OVER,
19/32'' APA RATED PLY WD ROOF SHEATHING, PEEL & STICK
WEATHER RESILIANT MEMBRANE , OVER MIXED RF FRAMING -
2x6'' RAFTERS @ 16'' O.C. & 2X8'' CEILING JOIST @ 16'' O.C. TYP
T.O - w/12" O.H. & 16'' O.H. A.F.E. BUILDER TO VENT ROOF
1/300MIN - ROOF SHALL BE NAILED PER IRC. 2018 REQ.
12
8
8x16'' CMU SUPPORT
FOUNDATION WALL
w/ 12'' x 24'' FTR.
12'' WD.
COLUMN
12
8
12
8
12
8
STAIRS TO GRADE
BY BUILDER
6'' CRAFTSMAN STYLE
TRIM & LENTIL
GABLE END
COLAR TIE 4X6
GABLE END OPEN 4X6 PT
POST FRAMED END WALL
RAFTER & UPRIGHTS
8x16'' CMU SUPPORT
FOUNDATION WALL
w/ 12'' x 24'' FTR.
IMPACT
EGRESS
IMPACT FIXEDIMPACT FIXED
IMPACT EGRESS
96''
Hdr Hgt
96''
Hdr Hgt
IMPACT EGRESSIMPACT EGRESS
TAPER GRADE
10' - T.O.B.
IMPACT
EGRESS
CLG HGT IN ATTIC AREA
F.F.E. @
ATTIC AREA
16'' OPEN WEB FLR JOIST @ 16'' O.C. TYP.
RIDGE LINE OF GABLE ROOF
4'' CONC. SLAB FOUNDATION @ REAR PATIO
AREA w/ BRICK ROW LOC @ EDGE2x12'' FLR JOIST UNDER
OFFICE & CLOSET AREA
4'' CONC SLAB FOUNDATION @
NEW CONST. FLOOR AREAS
(SEE FOUNDATION PL.)
4'' CONC SLAB FOUNDATION @
NEW CONST. FLOOR AREAS
(SEE FOUNDATION PL.)
HE
I
G
H
T
M
A
Y
V
A
R
Y
BA
S
E
D
O
N
S
L
O
P
E
OF
G
R
A
D
E
F.F.E.F.F.E.
F.G.E.
9'
-
1
"
2'-0"2'-0"
1'
-
0
"
9'
-
4
"
10
'
-
5
"
1'
-
5
"
22
'
-
5
"
25
'
-
1
1
"
8'
-
1
"
6'
-
0
"
10
'
-
5
"
9'
-
6
"
8'
-
0
"
10
'
-
1
"
8'
-
1
"
5'
-
1
"
8'
-
1
"
2'
-
6
"
9'
-
5
"
1'
-
0
"
1'
-
5
"
5'
-
1
"
3'
-
0
"
16'-4"
12'-4"
0"
1'
-
0
"
8'
-
1
"
12'' WD COL
1x6 T&G CLG FIN
3 PLY
1.78x 11.78
LVL BEAM
STEPS TO GRADE
BY BUILDER
3 PLY
1.78x 11.78
LVL BEAM
1' STEP UP TO 9 FT CENTER
F.F.E.
MAIN HSE-4'' @
PORCH
F.F.E. @ ATTIC
K.W. HGT @
EXTERIOR
CLG HGT IN ATTIC RM
T.O.B.
T.O. COL.
36''x96'' ARCH
OPEN TO HALL
UNDER STAIRS
F.F.E. @
ATTIC
BRICK TRIM
IMPACT
EGRESS
3 PLY 1.78 x 11.78
LVL BEAM @ SIDE
2X6'' RAFTERS @ 16'' O.C.TYP
ROOF FRAMING
2X6'' or 8'' RAFTERS @ 16''
O.C.TYP ROOF FRAMING
2x6'' & 8'' ceiling joist
where shown
2x6'' & 8'' ceiling joist
where shown
2X8'' roof rafters @ 16'' o.c.
typ thru open gable
4X6 pt post
supports
EXISTING FOUNDATION AREA -
NOT TO BE DISTURBED
4'' STEP DN TO PATIO
12'' WD
COL
2x8'' EXISTING FLR JOIST
80''
HGT
SNACK
BAR
EGRESS
WINDOW
EGRESS
WINDOW
DR ACCESS TO
MECHANICAL AREAS
STORAGE
UNDER
STAIRS
EXT WALL OF MAIN HSE
EXISTING MAIN
EXT. END WALL
EXISTING MAIN EXT. END WALL NEW SUP. FD WALL @ PORCH
#1 BUILDER TO STRAP ALL EXISTING BEAMS TO PIER SUPPORTS
#2 BUILDER TO STRAP OR USE SP1 CON. @ ALL EXISTING BOTTOM PLATES TO NEW STUD FRAMING
#3 BUILDER TO VERIFY ALL HEIGHTS TO FINISH GRADE BASED FROM SURVEY T.B.M.
#4 ADJUST BLOCK STEM WALL HEIGHTS TO ALLOW FOR SLOPPED GRADE @ FOOTINGS @ SIDES &
REAR SLOPES OF GRADE
16'' OPEN WEB FLR JOIST @ 16'' O.C. TYP.16'' OPEN WEB FLR JOIST @ 16'' O.C. TYP.
2X4 NEW FRAMED WALL SECTION IN
AREAS UNDER ROOF w/ R15
INSULATION & 1/2'' GYP BD.
TV
ELEC
FIREPLACE
INSERT
PKT DR
TO
EXERCISE
RM
CLG HGT IN AREA UNDER ROOF
96''
Hdr Hgt
4'' CONC SLAB THIS AREA 4'' CONC SLAB THIS AREA
8x16'' CMU SUPPORT FOUNDATION
WALL w/ 12'' x 24'' FTR.- BACK FILL
AREA - COMPACT TO MIN 2500 PSF
8x16'' CMU SUPPORT FOUNDATION
WALL w/ 12'' x 24'' FTR.-- BACK FILL
AREA - COMPACT TO MIN 2500 PSF
END WALL OF
EXISTING STRUCTURE
SUPPORT WALL OF
NEW STRUCTURE
EXISTING
STRUCTURE
NEW
CONSTRUCTION
2X6'' or 8'' RAFTERS @ 16''
O.C.TYP ROOF FRAMING
PRINT DATES
FINAL PRINT - 12/09/25
DESIGN DRAWN BY
Kirk A. ThomasKirk A. ThomasKirk A. ThomasKirk A. Thomas
To
t
h
e
b
e
s
t
o
f
m
y
k
n
o
w
l
e
d
g
e
t
h
e
s
e
p
l
a
n
s
a
r
e
d
r
a
w
n
t
o
c
o
m
p
l
y
w
i
t
h
t
h
e
c
o
d
e
r
e
q
u
i
r
e
m
e
n
t
s
f
o
r
th
e
i
r
i
n
t
e
n
d
e
d
u
s
e
b
y
o
w
n
e
r
'
s
a
n
d
/
o
r
b
u
i
l
d
e
r
'
s
s
p
e
c
if
i
c
a
t
i
o
n
s
,
a
n
y
c
h
a
n
g
e
s
m
a
d
e
o
n
o
r
t
o
t
h
e
m
af
t
e
r
p
r
i
n
t
s
a
r
e
s
e
a
l
e
d
w
i
l
l
b
e
d
o
n
e
a
t
t
h
e
o
w
n
e
r
'
s
a
n
d
/
o
r
b
u
i
l
d
e
r
'
s
e
x
p
e
n
c
e
a
n
d
r
e
s
p
o
n
s
i
b
i
l
i
t
y
.
Th
e
c
o
n
t
r
a
c
t
o
r
s
h
a
l
l
v
e
r
i
f
y
a
l
l
d
i
m
e
n
s
i
o
n
s
a
n
d
e
n
c
l
os
e
d
d
e
t
a
i
l
d
r
a
w
i
n
g
s
.
R
e
f
e
r
I
n
s
t
a
l
l
a
t
i
o
n
o
f
a
l
l
ma
t
e
r
i
a
l
s
t
o
m
a
n
u
f
a
c
t
u
r
e
s
a
n
d
c
o
d
e
r
e
q
u
i
r
m
e
n
t
s
f
o
r
ea
c
h
i
t
e
m
s
a
t
t
a
c
h
m
e
n
t
t
o
t
h
e
s
t
r
u
c
t
u
r
e
re
q
u
a
r
d
l
e
s
s
o
f
d
e
t
a
i
l
s
h
o
w
n
.
D
e
t
a
i
l
s
a
r
e
n
o
t
s
p
e
c
i
fi
c
t
o
s
t
r
u
c
t
u
r
e
d
r
a
w
n
,
d
e
t
a
i
l
s
a
r
e
d
r
a
w
n
a
s
pe
r
s
p
e
c
t
i
v
e
c
u
t
a
w
a
y
v
i
e
w
s
a
n
d
i
n
n
o
w
a
y
s
h
o
w
m
a
t
e
r
i
al
i
t
e
m
s
a
s
f
i
n
i
s
h
e
d
i
n
s
t
a
l
l
e
d
re
p
r
e
s
e
n
t
a
t
i
o
n
.
k
.
a
.
t
.
D
e
s
i
g
n
s
I
n
c
.
i
s
n
o
t
l
i
a
b
l
e
f
or
e
r
r
o
r
s
b
a
s
e
d
u
p
o
n
p
e
r
s
o
n
a
l
i
n
t
e
r
p
r
e
t
a
t
i
o
n
of
a
n
y
d
e
t
a
i
l
,
t
e
x
t
i
t
e
m
,
o
r
s
y
m
b
o
l
u
s
e
d
i
n
t
h
e
c
r
e
at
i
o
n
o
f
t
h
e
s
e
d
o
c
u
m
e
n
t
s
.
W
h
i
l
e
e
v
e
r
y
e
f
f
o
r
t
ha
s
b
e
e
n
m
a
d
e
i
n
t
h
e
p
r
e
p
a
r
a
t
i
o
n
o
f
t
h
i
s
p
l
a
n
t
o
a
v
oi
d
m
i
s
t
a
k
e
s
,
t
h
e
m
a
k
e
r
c
a
n
n
o
t
g
u
a
r
a
n
t
e
e
ag
a
i
n
s
t
h
u
m
a
n
e
r
r
o
r
.
T
h
e
L
i
c
.
C
o
n
t
r
a
c
t
o
r
/
O
w
n
e
r
s
o
f
th
e
p
r
o
j
e
c
t
m
u
s
t
c
h
e
c
k
a
l
l
d
i
m
e
n
s
i
o
n
s
a
n
d
de
t
a
i
l
s
p
r
i
o
r
t
o
c
o
n
s
t
r
u
c
t
i
o
n
a
n
d
b
e
s
o
l
e
l
y
r
e
s
p
o
n
s
ib
l
e
u
p
o
n
i
s
s
u
e
d
p
e
r
m
i
t
.
A
l
l
i
n
f
o
r
m
a
t
i
o
n
co
n
t
a
i
n
e
d
w
i
t
h
i
n
t
h
e
s
e
p
l
a
n
s
i
s
s
u
b
j
e
c
t
t
o
c
h
a
n
g
e
b
as
e
o
n
c
o
d
e
r
e
q
u
i
r
e
m
e
n
t
s
a
n
d
p
e
r
m
i
t
t
i
n
g
ju
r
i
s
d
i
c
t
i
o
n
I
n
t
e
r
p
r
e
t
a
t
i
o
n
.
Page #Page #Page #Page #
PL
A
N
S
C
A
L
E
:
BA
S
E
@
1
/
4
"
=
1
'
-
0
'
'
U.
O
.
N
.
S
C
A
L
E
M
A
Y
V
A
R
Y
P
E
R
P
L
A
N
OR
P
E
R
D
E
T
A
I
L
(
N
O
T
S
P
E
C
I
F
I
C
)
Building Code: IRC2018
Design Wind Speed: 130 mph
ASD - ASCE 7-10
Design Wind Speed: 160 MPH
Ultimate - ASCE 7-16
Req. Glazing & Door Design
Pressures (DP's) 50 psf
All Doors and Glazing Installed
shall be Impact Rated
Flood Zone: FIRM - X
Finish Floor Elevation:
Min. 36'' A.CL.RW.
Mean Roof Height:
A 1.5A 1.5A 1.5A 1.5
I,
L
a
r
r
y
M
.
O
l
i
v
e
r
,
P
.
E
.
,
L
i
c
e
n
s
e
N
o
.
1
2
6
7
8
Ce
r
t
i
f
y
t
h
a
t
t
h
e
s
t
r
u
c
t
u
r
a
l
p
o
r
t
i
o
n
s
o
f
t
h
i
s
se
t
o
f
c
o
n
s
t
r
u
c
t
i
o
n
d
o
c
u
m
e
n
t
s
h
a
v
e
b
e
e
n
re
v
i
e
w
e
d
u
n
d
e
r
m
y
r
e
s
p
o
n
s
i
b
l
e
c
h
a
r
g
e
,
de
s
i
n
a
t
e
d
b
y
d
e
s
i
g
n
,
t
o
c
o
m
p
l
y
w
i
t
h
t
h
e
en
g
i
n
e
e
r
i
n
g
r
e
q
u
i
r
e
m
e
n
t
s
o
f
t
h
e
In
t
e
r
n
a
t
i
o
n
a
l
R
e
s
i
d
e
n
t
i
a
l
B
u
i
l
d
i
n
g
C
o
d
e
,
20
1
8
L
a
t
e
s
t
E
d
i
t
i
o
n
@
1
3
0
/
1
6
0
-
m
p
h
3
se
c
g
u
s
t
w
i
n
d
l
o
a
d
r
a
t
i
n
g
.
La
r
r
y
M
.
O
l
i
v
e
r
E
n
t
e
r
p
r
i
s
e
s
I
n
c
.
72
2
8
O
a
k
b
r
i
a
r
D
r
i
v
e
S
o
u
t
h
Mo
b
i
l
e
,
A
L
.
3
6
6
1
9
PE
R
M
I
T
J
U
R
I
S
D
I
C
T
I
O
N
:
CI
T
Y
O
F
F
A
I
R
H
O
P
E
B.
F
.
E
.
:
1
2
'
'
A
.
C
L
.
R
W
FL
O
O
D
Z
O
N
E
:
"
X
"
CO
N
T
R
A
C
T
O
R
:
S
T
E
V
E
J
O
N
E
S
C
O
N
T
R
A
C
T
O
R
PR
O
J
E
C
T
:
R
E
M
O
D
E
L
S
I
N
G
L
E
F
A
M
I
L
Y
R
E
S
.
CL
I
E
N
T
:
L
U
C
I
N
D
A
&
C
H
I
P
C
H
A
P
P
E
L
L
E
LO
C
A
T
I
O
N
:
F
A
I
R
H
O
P
E
,
A
L
.
PH
Y
S
I
C
A
L
A
D
D
R
E
S
S
:
2
1
0
G
A
Y
F
E
R
C
T
.
Base Slab Elev: 24''' A.F.G. (Varies)
FINAL REVIEW - 12/04/25
PRELIM. REVIEW -09/16/25
PRELIM. REVIEW - 11/04/25
PRELIM. REVIEW - 10/07/25
PRELIM. REVIEW -09/17/25
c
2
0
2
5
C
O
P
Y
R
I
G
H
T
B
Y
K
.
A
.
T
.
D
e
s
i
g
n
s
I
n
c
.
T
h
e
s
e
d
r
a
w
i
ng
s
a
r
e
N
O
T
T
O
B
E
re
p
r
o
d
u
c
e
d
o
r
c
o
p
i
e
d
i
n
a
n
y
f
o
r
m
w
h
a
t
s
o
e
v
e
r
w
i
t
h
o
u
t
t
h
e
w
r
i
t
t
e
n
pe
r
m
i
s
s
i
o
n
o
f
K
.
A
.
T
.
D
e
s
i
g
n
s
I
n
c
.
-
A
N
Y
D
U
P
L
I
C
A
T
I
O
N
I
S
P
R
O
H
I
B
I
T
E
D
A
N
D
PU
N
I
S
H
A
B
L
E
U
N
D
E
R
F
E
D
E
R
A
L
L
A
W
.
T
h
e
p
u
r
c
h
a
s
e
r
h
a
s
t
h
e
ri
g
h
t
t
o
O
N
E
US
E
f
o
r
p
e
r
m
i
t
t
i
n
g
p
u
r
p
o
s
e
s
,
a
n
y
f
u
t
u
r
e
u
s
e
o
f
t
h
e
pl
a
n
,
i
d
e
a
s
,
e
l
e
v
a
t
i
o
n
s
,
co
n
t
e
n
t
s
,
o
r
c
h
a
n
g
e
s
t
o
d
e
s
i
g
n
a
r
e
t
h
e
p
r
o
p
e
r
t
y
o
f
K
.
A
.
T
.
D
e
s
i
g
n
s
I
n
c
.
AN
D
M
U
S
T
B
E
A
U
T
H
O
R
I
Z
E
D
B
Y
K
.
A
.
T
.
D
e
s
i
g
n
s
I
n
c
.
A
N
Y
U
NA
T
H
O
R
I
Z
E
D
U
S
E
WI
L
L
B
E
P
U
N
I
S
H
A
B
L
E
U
N
D
E
R
F
E
D
E
R
A
L
C
O
P
Y
R
I
G
H
T
L
A
W
S
.
CO
N
T
.
E
X
T
E
R
I
O
R
R
E
A
R
-
S
O
U
T
H
E
R
N
EL
E
V
A
T
I
O
N
w
/
C
U
T
T
H
R
U
V
I
E
W
&
EX
T
E
R
I
O
R
N
O
T
E
S
A
N
D
D
E
T
A
I
L
S
REAR / SOUTHERN ELEVATION
- SCALE 1/4'' = 1'-0''
SECTION CUT THRU CENTER FACING TO
EASTERN ELEVATION - SCALE 1/4'' = 1'-0''
CT
A 1.5
WL
A-1
WL
A-1
WL
A-1
WL
B-1
WL
A-1
WL
A-1
Page 24 of 63
{MSTA}
18'' or Eq.
3 PLY 1 7/8'' x
11.78'' LVL
BEAM
PORCH HEADER BEAM
CON. TO POST
PC
1
WINDOW INSTALLATION RESPONSIBILITY - 2018 IRC SECTIONS - 308 - 310 - 311 TO INCLUDE SUB SEC.
===================================================
IT IS THE RESPONSIBILITY OF THE BUILDER/OWNER TO VERIFY THAT ALL DOOR & WINDOW GLASS AREAS COMPLY TO SECTION
R-308.4 OF THE IRC 2018 GLAZING CODE RESTRICTIONS ARTICLES 1-9 INCLUDING THE EXCEPTIONS NOTES. ALL WINDOW
PROTECTION MUST COMPLY WITH IRC SECTION R301.2.1.2 COMPONENTS AND CLADDING PRESSURE ZONES TO INCLUDE THE
EXCEPTION NOTES & TABLES REFERENCED THEREIN. BUILDER/OWNER MUST FURNISH WINDOW DATA TO BUILDING DEPT. TO
VERIFY COMPLIANCE WITHIN IRC 2018 WINDOW GUIDLINES. ALL WINDOWS MUST MEET MIN DPI 50 RATING, IMPACT RATED
WINDOWS SHALL BE INSTALLED IN THIS RESIDENCE MEETING THE 130/160 mph REQ OR PER LOCAL CODE ORD. ALL WINDOWS
SHALL BE IMPACT RATED OR BUILDER MUST PROVIDE PROTECTIVE COVERING WITHIN CODE REQ. OPTION: ( OPPERABLE
APPROVED HURRICANE TYPE PROTECTION SECURED TO STRUCTURE, ROLL DOWN SHUTTERS or 3M KEVLAR SCREEN MAY BE
USED INSTEAD OF IMPACT RATED WINDOWS. INFORMATION MUST BE PROVIDED BY BUILDER DURING CONST. OR UPON
INSPECTION ) NOTE: Windows shown, may be impact rated, and must provide 5.7 SF clear opening in sleeping rooms. All sleeping
room Windows per Schedules are sized @ MIN. 3/0-6/0 provides a min. opening of the bottom sash @ 8.25 sf. All others are to provide
an egress of a min. 36'' x 80'' door or larger exiting to the outside of the Ext. All windows within 2'-0'' of a door must be Tempered
completely.Window Fall Protection: Window openings control devices meeting ASTM2090 must be installed on all Windows that have
an opening less than 24in fron the finish floor and the opening is 72in above the exterior grade. (R312.2)
D27-9070D01-9070
D2
1
-
2
6
8
0
W0
9
-
3
0
6
0
S
C
W0
2
-
2
0
4
4
F
X
W0
2
-
2
0
4
4
F
X
W0
6
-
2
8
6
0
S
C
W0
5
-
2
8
6
0
F
X
34
8
0
C
S
O
P
D08-3080
D18-2680
D0
7
-
3
0
8
0
D13-3080
W1
2
-
5
0
5
0
F
X
W0
4
-
2
6
2
6
F
X
D1
2
-
3
0
8
0
D20-2680
D03-6080
D26-2080
D2
4
-
2
4
8
0
D2
9
-
3
0
8
0
D38-2080
D17-2680
W11-3968
D25-2470
D32-5080
D3
7
-
3
0
8
0
D22-2668 30
8
0
A
R
C
H
O
P
D36-2680
D27-9070
W0
1
-
2
0
4
0
D
H
W1
1
-
4
0
4
0
F
X
W0
1
-
2
0
4
0
D
H
W14-3950FX W13-3918FX
30
8
0
A
R
C
H
O
P
W08-2870FX W08-2870FX D02-6080 W08-2870FX W08-2870FX D09-3080
W14-3950FX W13-3918FX
W0
3
-
2
6
2
0
F
X
D34-2880
D15-2880
D33-3080
W07-2870DH W07-2870DH W07-2870DH W07-2870DH
D35-2880D19-2680
D1
6
-
2
8
8
0
D0
6
-
3
0
8
0
D1
0
-
3
0
8
0
D30-3080
D31-2880
D2
8
-
2
6
8
0
42'' x 96'' C.O.
D05-4080
D04-5080
D1
4
-
3
0
8
0
42'' x 96'' C.O.D23-2668
D1
1
-
3
0
8
0
W07-2870DH W07-2870DH W07-2870DH W07-2870DH W10-3070DH W10-3070DH
D/W D/W
REF.
UP
DN
NEW SINGLE CAR GARAGE
12' CEILINGEXISTING 2 CAR GARAGE
EXISTING SECONDARY MASTER
HER CLOSET
EXISTING
BEDROOM #3
EXT. GUEST BATH #3
EXISTING CLOSET ac (low)
CLOSET
wc
EXT.
BATH #2
HALL
shwr
D.N.D.
HALL
NEW MASTER BATH
COVERED PATIO AREA
10' BASE PLT w/ VAULTED CEILING
OPEN TO ABOVE
WI
CLOSET
BATH #4
bu
l
k
p
a
n
t
r
y
WORKOUT ROOM
10' CLG.
WC
WI
C
L
O
S
E
T
SHWR
FAMILY/ GREATROOM
POOL
SHWR
LAUNDRY
NEW OFFICE
HALL
POOL
BATH
MASTER HALL
HIS CLOSET
W.C.
ENTRY
NEW MASTER SUITE
COVERED PORCH
OFFICE SUPPLY CLOSETSAFE
LOC
EXISTING DINING
/ENTRY AREA
NEW 10' CLG HGT
31'-1"
29'-3"
17
'
-
5
"
1'
-
0
"
4'
-
0
"
1'-4"1'-2"
4'
-
0
"
9'-0"
3'
-
0
"
4'-2"4'-1"2'-9"
3'
-
1
0
"
7'-1"5'-8"
7'-1"
2'
-
7
"
16'-11"3'-6"
4'
-
2
"
8'
-
5
"
12
'
-
4
"
7"
2'-0"
7"
3'
-
1
"
2'-3"
14'-0"22'-11"24'-2"12'-7"
73'-8"
4'-7"
4'
-
0
"
21
'
-
5
"
5'
-
3
"
7'
-
2
"
10
'
-
9
"
2'
-
1
1
"
13
'
-
3
"
64
'
-
9
"
15
'
-
1
1
"
5'
-
5
"
78'-3"
30'-7"
16
'
-
2
"
5'
-
1
0
"
4'
-
7
"
14
'
-
5
"
5'
-
3
"
5'
-
4
"
5'
-
6
"
2'
-
7
"
12
'
-
1
0
"
82
'
-
1
"
5'
-
5
"
4'
-
0
"
4'
-
2
"
18'-3"
18'-9"
1'-0"9'-0"1'-0"9'-1"1'-0"9'-0"1'-0"
1'
-
0
"
7'
-
6
"
1'
-
0
"
7'
-
1
0
"
17
'
-
4
"
1'
-
0
"
3'
-
0
"
12
'
-
2
"
3'-5"2'-8"5"2'-8"5"2'-8"5"2'-8"3'-5"
4'-2"4'-7"3'-0"2'-9"8"2'-8"11"
6"
2'
-
8
"
2'
-
8
"
4'
-
0
"
1'
-
1
0
"
18'-9"
2'-0"2'-0"
3'-7"5'-4"1'-5"
10'-4"4'-3"
3'-2"5'-4"3'-4"2'-1"
4'
-
4
"
5'-5"
4'-7"3'-2"
4'-2"1'-9"1'-10"1'-9"3'-7"
13'-11"
20'-3"
23
'
-
0
"
10"2'-8"5"2'-8"6"6'-0"6"2'-8"5"2'-8"5"
8'
-
7
"
6'
-
2
"
8'
-
1
"
18'-0"2'-0"10'-7"
16'-11"12'-0"
2'-6"1'-7"3'-0"5"3'-4"
7'-4"
5'-4"5'-3"
2'-11"2'-8"5"2'-8"5"2'-8"5"2'-8"2'-5"2'-10"3'-1"3'-0"3'-1"
2'
-
3
"
11
'
-
0
"
2'
-
1
1
"
10'-6"3'-6"2'-11"
5'
-
9
"
12
'
-
9
"
4'
-
5
"
4'
-
3
"
5'
-
6
"
6'
-
5
"
6'
-
4
"
4'
-
5
"
8"
3'
-
0
"
9"
3'-10"3'-0"3'-9"3'-0"4'-0"3'-0"6"3'-6"6"
10'-7"3'-11"4'-5"2'-6"3'-0"8"
7"2'-6"7"8'-4"
1'
-
8
"
3'
-
0
"
1'
-
8
"
4'
-
5
"
1'
-
9
"
6'
-
1
0
"
8'
-
7
"
10'-10"
3'
-
6
"
5'
-
2
"
10'-10"3'-0"2'-8"
3'
-
5
"
5'
-
2
"
3'
-
1
0
"
3'-6"
6"2'-6"6"
2'
-
3
"
1'-0"3'-0"13'-5"6'-7"2'-8"
2'
-
2
"
3'
-
0
"
16
'
-
3
"
4'
-
0
"
8'
-
7
"
2'-2"
4'-0"2'-2"14'-5"
12
'
-
5
"
8'-4"
8"
2'-6
"
7"
4'-5"
12'-10"
14'-5"
6'-0"4'-4"
4'
-
7
"
6"
3'
-
0
"
2'
-
2
"
8'
-
5
"
3'-6"
10'-4"
10"6'-0"7"2'-11"7"2'-6"5"
1'
-
2
"
2'
-
8
"
6'
-
2
"
2'
-
8
"
3'
-
8
"
2'
-
0
"
9'
-
8
"
2'
-
0
"
4'
-
6
"
3'
-
0
"
8'
-
5
"
5'-5"3'-9"4'-10"
6'
-
2
"
7'-3"10"6'-6"10"7'-6"
1'
-
8
"
1'
-
6
"
5'
-
0
"
7'
-
1
"
5'-6"9'-0"4'-1"
15
'
-
8
"
4'-0"
3'
-
0
"
16'-8"
3'-5"
9'
-
1
1
"
25
'
-
5
"
26'-6"
5'
-
0
"
4'-0"
82
'
-
1
"
2'-0"9'-0"2'-2"9'-0"2'-0"
1'-7"9'-0"1'-7"
11
"
3'
-
0
"
17
'
-
6
"
2'
-
1
0
"
2'
-
0
"
4'
-
0
"
2'
-
0
"
17
'
-
6
"
5'
-
0
"
2'
-
1
"
2'
-
6
"
1'
-
5
"
13
'
-
3
"
6'
-
4
"
6"3'-6"6"
3'-8"1'-6"5'-0"1'-10"
3'-1"3'-9"2'-0"5'-0"2'-0"3'-9"3'-4"
28'-11"
36
'
'
H
I
D
D
E
N
CA
B
AC
C
E
S
S
BUTLERS PANTRYOPEN EXPOSED WALL AREA
LIN CL
66
'
'
V
A
N
I
T
Y
SH
W
R
SE
A
T
36
'
'
TA
L
L
CA
B
36
'
'
TA
L
L
CA
B
FO
L
D
I
N
G
C
O
U
N
T
E
R
HA
N
G
I
N
G
CL
O
T
H
E
S
A
R
E
A
UP
P
E
R
&
LO
W
E
R
C
A
B
S
UP
P
E
R
C
A
B
S
UP
P
E
R
C
A
B
S
30'' x 60''
ISLAND DRESSER
W/ ELEC
30'' TALL
CAB
12'' UPPER SHELVING
W
D
4'' STEP DN
20'' EXTENDED BAR TOP
w/ SUPPORTS
10' CLG.
10
'
C
L
G
.
10' CLG.
10' CLG.
10' CLG.
10' CLG.
10' CLG.
10' CLG.
10' CLG.
10' CLG.
10' CLG.
10
'
B
A
S
E
W
A
L
L
H
G
T
10
'
B
A
S
E
W
A
L
L
H
G
T
new 2 ply 1.78'' x 11.78'' LVL
header beam installed in ceiling
@ wall transition
dbl wall
ovens
LOCKED
DOOR w/
DEADBOLT
12'' FIN COL w/ 10'' INTERIOR PT POST CORE
w/ HARDIE WRAP EXT
42'' METAL FIN AWNING w/ 4'' X4 PT RANCH CORBEL SUPPORT
ZERO ENTRY
@ SHOWER
10' CLG.
10' CLG.
10' CLG.
10' CLG.
10' CLG.
10' CLG.
NEW CLG HGT 10'
10' CLG.
10' CLG.
10' CLG.
24
'
'
S
I
N
K
MI
C
R
O
BAR SINK
DRs SLIDE
BACK IN SIDES
OF CAB
STATIONARY
STAIR BY
LIFT UP INC.
SEE BUILDER
FOR SPECS
60
'
'
F
R
I
G
/
F
R
E
E
Z
E
R
BU
I
L
T
I
N
COFFEE
BAR
IC
E
M
K
R
36
'
'
G
A
S
C
T
.
MI
R
R
O
R
45X57 ORIG
drop zone bench seat
LOCKED
DOOR w/
DEADBOLT
temp gls
27
'
'
TA
L
L
LI
N
C
A
B
EN
T
R
Y
U
N
D
E
R
ST
A
I
R
S
STORAGE
AREA w/
ACCESS
UNDER STAIRS
TI
L
E
S
H
O
W
E
R
S
E
A
T
30'' VAN
48'' SINK BASE
72'' X 36'' FREE
STANDING TUB
45
'
'
M
K
U
P
VA
N
I
T
Y
t
r
a
s
h
dr
a
w
e
r
t
r
a
s
h
dr
a
w
e
r
LANDING
8'-0'' 'VANITY
24'' DRW
STK
MICRO
UPPER WINE CAB
12'' EXTENDED BAR TOP
PLUG FOR
ELEC CAR
re
l
o
c
a
t
e
d
ga
s
m
e
t
e
r
re
l
o
c
a
t
e
d
El
e
c
m
e
t
e
r
stairs to grade
by builder
16'' SHELVING w/ ROD
16
'
'
S
H
E
L
V
I
N
G
w/
R
O
D
16
'
'
S
H
E
L
V
I
N
G
w/
R
O
D
16'' LOWER SHELVING w/ HANGING ROD
16
'
'
L
O
W
E
R
S
H
E
L
V
I
N
G
w/
H
A
N
G
I
N
G
R
O
D
12
'
'
U
P
P
E
R
S
H
E
L
V
I
N
G
12'' UPPER SHELVING
16'' LOWER SHELVING w/ HANGING ROD
LO
W
E
R
-
O
P
E
N
FO
R
L
D
R
Y
B
S
K
T
27
'
'
TA
L
L
LI
N
C
A
B
24''
DRW
STK
24'' DRW
STK
48'' SINK BASE
8'-0'' 'VANITY
24''
DRW
STK
SPRAYER
DUEL SHWR HEADS
SLAB RAISED TO MEET
EXISTING GARAGE
FLOOR LEVEL LESS 4''
DROP DN. (NO STEPS)
EL
E
C
/
G
A
S
VE
N
T
L
E
S
S
F
P
48
'
'
B
U
I
L
T
I
N
48
'
'
B
U
I
L
T
I
N
OUT TO OUT OF FRAMING
FRAMING OUT TO OUT OF RAIL
OUT TO OUT
OF FRAMING
OUT TO OUT OF FRAMING
AIR
COMPRESSOR
12'' TIMBER POST COL
w/ABU1212Z ANCHOR TO
SLAB TYP. T.O.
3 PLY 1.78'' x 11.78'' LVL
HEADER BEAM
3
P
L
Y
1
.
7
8
'
'
x
1
1
.
7
8
'
'
L
V
L
HE
A
D
E
R
B
E
A
M
2 PLY 1.78'' x 11.78''
LVL HEADER BEAM
10' 5''
T.O.B.
10' 5''
T.O.B.
10' 5''
T.O.B.
SH
E
L
V
I
N
G
w
/
R
O
D
EXTERIOR WALL OF
EXISTING HOUSE
EXISTING 2x WALL @ 8' PLT HGT w/ 2'
K.W. BUILT ATOP USE TIMBER SCREWS
@ EVERY 24'' O.C. TOP PLT TO NEW K.W.
BOTTOM PLATE CON. APPLY EXT SHEAR
WALL SHEATHING PLATE TO PLATE
EXISTING 2x WALL @ 8' PLT HGT w/ 2'
K.W. BUILT ATOP USE TIMBER SCREWS
@ EVERY 24'' O.C. TOP PLT TO NEW K.W.
BOTTOM PLATE CON. APPLY EXT SHEAR
WALL SHEATHING PLATE TO PLATE
NEW CLG HGT 10'
ALL EXISTING INTERIOR WALLS SHALL
HAVE A NEW K.W. @ 24'' HGT FRAMED
ATOP & CONNECTED @ PLATES w/
TIMBER SCREWS EVERY 24'' O.C. TYP T.O.
NEW CLG HGT 12'
ALL NEW CONST. EXT/ INTERIOR
WALLS SHALL BE 2X6'' @ 10' 1
1/8'' T.O.P. TYP T.O.
TALL
CAB
HALL
2x WALL SUR
FRAMED IN
REFRIG. SIDES
16
'
'
S
H
E
L
V
I
N
G
16'' SHELVING
EXISTING LIVING RM
temp gls
RAIN
HD
2x6
WALL
2x6
WALL
2x
6
WA
L
L
HIDDEN
DR
2x6
WAL
L
2x6
WALL
2x
6
WA
L
L
2x6
WALL
2x6WALL
2x6
WAL
L
2x4
EXISTING WL
2x4
EXI
S
T
I
NG W
L
2x4
EXISTING WL
2x4
EXISTING WL
2x
4
@
4
0
'
'
H
G
T
EX
I
S
T
I
N
G
W
L
2x4
EXISTING WL
STEPS TO GRADE
BY BUILDER
STAIRS REMOVED
FOR CLARITY
TUB
D.N.D.
BATH FIXTURES TO
REMAIN AS IS
BATH FIXTURES TO
REMAIN AS IS
16
'
'
d
U
P
P
E
R
C
A
B
S
HO
O
D
V
T
R
36''d BASE CAB
2x
4
EX
I
S
T
I
N
G
W
L
KEEP MIN 6'' AWAY
FROM WALL EDGE
LA
N
D
I
N
G
EXISTING BASE
SUP. 8'' CMU
SOLID BLK WALL
MATCH EXT WL HGT w/
EXISTING EXT. WL PLUS
THE 2 FT K.W.
CUSTOM DR BY OWNERS
CUSTOM DR BY OWNERSCUSTOM DR BY OWNERS
2x6
WALL
4'' STEP DN
TRANSOM
ABOVE
TRANSOM
ABOVE
PC
1/2
PC
1/2
PC
1/2
PC
1/2
PC
1/2
PC
1/2
CT
A1.8
CT
A1.5
CT
A1.5
FU
L
L
W
A
L
L
EXPOSED RAILING
FRAMING OUT TO
PORCH EDGE
FIRST FLOOR INTERIOR & EXTERIOR IMPACT RATED DOOR SCHEDULE
NUMBER QTY FLOOR SIZE DIMENSIONS DESCRIPTION
D01 1 1 9070 108X84" GARAGE DR - BY OWNER
D02 1 1 6080 L/R EX 36X96X1 3/4" L/R EX FRENCH DR GLASS IMPACT
D03 1 1 6080 IN 72X96" IN CLOSET - POCKET PANEL DOOR
D04 1 1 5080 L/R EX 30X96X1 3/4" L/R EX FRONT DR. - CRAFTSMAN ENTRY DOOR
D05 1 1 4080 DBL 24X96X1 3/8" DBL HIS CLOSET - DBL POCKET PANEL DOOR
D06 1 1 3080 R IN 36X96X1 3/8" R IN PANEL DOOR
D07 1 1 3080 R EX 36X96X1 3/4" R EX GARAGE EXIT DR - PANEL TYPE
D08 1 1 3080 R EX 36X96X1 3/4" R EX HSE TO GARAGE ENTRY PANEL DOOR
D09 1 1 3080 R EX 36X96X1 3/4" R EX POOL BATH - CRAFTSMAN ENTRY DR IMPACT
D10 1 1 3080 L IN 36X96X1 3/8" L IN OFFICE ENTRY - PANEL DOOR
D11 1 1 3080 L EX 36X96X1 3/4" L EX EXERCISE EXIT DR - IMPACT GLS
D12 1 1 3080 L EX 36X96X1 3/4" L EX S.C.GARAGE - CRAFTSMAN EXIT DOOR
D13 1 1 3080 36X96X1 3/8" MASTER BATH ENTRY POCKET-PANEL
D14 1 1 3080 36X96X1 3/8" HER CLOSET - POCKET PANEL DOOR
D15 1 1 2880 R IN 32X96X1 3/8" R IN EXERCISE RM - ENTRY PANEL DOOR
D16 1 1 2880 L IN 32X96X1 3/8" L IN EXERCISE CLOSET - PANEL DOOR
D17 1 1 2680 R IN 30X96X1 3/8" R IN SEC MASTER ENTRY - PANEL DOOR
D18 1 1 2680 R IN 30 1/16X96X1 3/8" R IN MASTER W.C - PANEL DOOR
D19 1 1 2680 L IN 30X96X1 3/8" L IN EXERCISRE SHOWER - TEMP GLS
D20 1 1 2680 L IN 30X96X1 3/8" L IN EXISTING BED RM - ENTRY PANEL DOOR
D21 1 1 2680 30X96X1 3/8" BULK PANTRY - POCKET PANEL DOOR
D22 1 1 2668 L IN 30X80X1 3/8" L IN PANEL DOOR - UNDER STAIRS
D23 1 1 2668 30X80X1 3/8" SAFE RNM - POCKET PANEL DOOR
D24 1 1 2480 L IN 28X96X1 3/8" L IN EXISTING BATH #3 - ENTRY PANEL DR
D25 1 1 2470 R IN 28X84X1 3/8" R IN EXISTING SHOWER DR - TEMP GLS
D26 1 1 2080 R IN 24X96X1 3/8" R IN BATH #3 LINEN CL - PANEL DOOR
D27 2 1 9070 108X84" GARAGE DR BY OWNERS
D28 1 1 2680 L IN 30X96X1 3/8" L IN POOL SHOWER - TEMP GLS SHOWER DR
D29 1 1 3080 36X96X1 3/8" EXISTING BATH #2 POCKET PANEL DOOR
D30 1 1 3080 R IN 36X96X1 3/8" R IN LAUNDRY RM - PANEL DOOR
D31 1 1 2880 L IN 32X96X1 3/8" L IN LAUNDRY RM - PANEL DOOR
D32 1 1 5080 L/R IN 30X96X1 3/8" L/R IN OFFICE CLOSET - DBL. PANEL DR
D33 1 1 3080 36X96X1 3/8" EXERCISE RM - POCKET PANEL DOOR
D34 1 1 2880 L IN 32X96X1 3/8" L IN SEC. MASTER CLOSET - PANEL DOOR
D35 1 1 2880 L IN 32X96X1 3/8" L IN EXERCISE RM WC - PANEL DR
D36 1 1 2680 L IN 30X96X1 3/8" L IN LINEN CL - PANEL DOOR
D37 1 1 3080 36X96X1 3/8" LR - HALL - PRIVACY POCKET PANEL DOOR
D38 1 1 2080 R IN 24X96X1 3/8" R IN EXISTING BATH #2 - WC PANEL DOOR
FIRST FLOOR IMPACT RATED GLASS WINDOW SCHEDULE
NUMBER QTY FLOOR SIZE DIMENSIONS DESCRIPTION
W01 2 1 2040DH 24"X48"DH DOUBLE HUNG
W02 2 1 2044FX 24"X52"FX FIXED GLASS
W03 1 1 2620FX 30"X24"FX FIXED GLASS
W04 1 1 2626FX 30"X30"FX FIXED GLASS
W05 1 1 2860FX 32"X72"FX FIXED GLASS
W06 1 1 2860SC 32"X72"SC SNGL CASEMENT-HR
W07 8 1 2870DH 32"X84"DH DOUBLE HUNG
W08 4 1 2870FX 32"X84"FX FIXED GLASS
W09 1 1 3060SC 36"X72"SC SNGL CASEMENT-HR
W10 2 1 3070DH 36"X84"DH DOUBLE HUNG
W11 1 1 4040FX 48"X48"FX FIXED GLASS
W12 1 1 5050FX 60"X60"FX FIXED GLASS
W13 2 1 3918FX 45"X20"FX FIXED GLASS - TRANSOM
W14 2 1 3950FX 45"X60"FX FIXED GLASS
POST TO BEAM & BASE ANCHOR CONNECTION
PC
2
10'' & 12''
timber post
see plans
2 & 3 ply 2" x 12" #2 Pt. Header or 2 - 3 ply 1.75'' x 11.78'' LVL Header
(see plans for additional Header types)
ABU1010z
&
ABU1212z
POST BASE
ANCHOR5/8" X 10" ANCHOR
BOLT IN SLAB
Notch Post & thru
bolt @ corners
2 @
SIMPSON
MSTA24 ea
side
Notch Post & thru
bolt @ mid. post
brick around
postbase (not shown)
2 @
SIMPSON
MSTA18
ea side
PRINT DATES
FINAL PRINT - 12/09/25
DESIGN DRAWN BY
Kirk A. ThomasKirk A. ThomasKirk A. ThomasKirk A. Thomas
To
t
h
e
b
e
s
t
o
f
m
y
k
n
o
w
l
e
d
g
e
t
h
e
s
e
p
l
a
n
s
a
r
e
d
r
a
w
n
t
o
c
o
m
p
l
y
w
i
t
h
t
h
e
c
o
d
e
r
e
q
u
i
r
e
m
e
n
t
s
f
o
r
th
e
i
r
i
n
t
e
n
d
e
d
u
s
e
b
y
o
w
n
e
r
'
s
a
n
d
/
o
r
b
u
i
l
d
e
r
'
s
s
p
e
c
if
i
c
a
t
i
o
n
s
,
a
n
y
c
h
a
n
g
e
s
m
a
d
e
o
n
o
r
t
o
t
h
e
m
af
t
e
r
p
r
i
n
t
s
a
r
e
s
e
a
l
e
d
w
i
l
l
b
e
d
o
n
e
a
t
t
h
e
o
w
n
e
r
'
s
a
n
d
/
o
r
b
u
i
l
d
e
r
'
s
e
x
p
e
n
c
e
a
n
d
r
e
s
p
o
n
s
i
b
i
l
i
t
y
.
Th
e
c
o
n
t
r
a
c
t
o
r
s
h
a
l
l
v
e
r
i
f
y
a
l
l
d
i
m
e
n
s
i
o
n
s
a
n
d
e
n
c
l
os
e
d
d
e
t
a
i
l
d
r
a
w
i
n
g
s
.
R
e
f
e
r
I
n
s
t
a
l
l
a
t
i
o
n
o
f
a
l
l
ma
t
e
r
i
a
l
s
t
o
m
a
n
u
f
a
c
t
u
r
e
s
a
n
d
c
o
d
e
r
e
q
u
i
r
m
e
n
t
s
f
o
r
ea
c
h
i
t
e
m
s
a
t
t
a
c
h
m
e
n
t
t
o
t
h
e
s
t
r
u
c
t
u
r
e
re
q
u
a
r
d
l
e
s
s
o
f
d
e
t
a
i
l
s
h
o
w
n
.
D
e
t
a
i
l
s
a
r
e
n
o
t
s
p
e
c
i
fi
c
t
o
s
t
r
u
c
t
u
r
e
d
r
a
w
n
,
d
e
t
a
i
l
s
a
r
e
d
r
a
w
n
a
s
pe
r
s
p
e
c
t
i
v
e
c
u
t
a
w
a
y
v
i
e
w
s
a
n
d
i
n
n
o
w
a
y
s
h
o
w
m
a
t
e
r
i
al
i
t
e
m
s
a
s
f
i
n
i
s
h
e
d
i
n
s
t
a
l
l
e
d
re
p
r
e
s
e
n
t
a
t
i
o
n
.
k
.
a
.
t
.
D
e
s
i
g
n
s
I
n
c
.
i
s
n
o
t
l
i
a
b
l
e
f
or
e
r
r
o
r
s
b
a
s
e
d
u
p
o
n
p
e
r
s
o
n
a
l
i
n
t
e
r
p
r
e
t
a
t
i
o
n
of
a
n
y
d
e
t
a
i
l
,
t
e
x
t
i
t
e
m
,
o
r
s
y
m
b
o
l
u
s
e
d
i
n
t
h
e
c
r
e
at
i
o
n
o
f
t
h
e
s
e
d
o
c
u
m
e
n
t
s
.
W
h
i
l
e
e
v
e
r
y
e
f
f
o
r
t
ha
s
b
e
e
n
m
a
d
e
i
n
t
h
e
p
r
e
p
a
r
a
t
i
o
n
o
f
t
h
i
s
p
l
a
n
t
o
a
v
oi
d
m
i
s
t
a
k
e
s
,
t
h
e
m
a
k
e
r
c
a
n
n
o
t
g
u
a
r
a
n
t
e
e
ag
a
i
n
s
t
h
u
m
a
n
e
r
r
o
r
.
T
h
e
L
i
c
.
C
o
n
t
r
a
c
t
o
r
/
O
w
n
e
r
s
o
f
th
e
p
r
o
j
e
c
t
m
u
s
t
c
h
e
c
k
a
l
l
d
i
m
e
n
s
i
o
n
s
a
n
d
de
t
a
i
l
s
p
r
i
o
r
t
o
c
o
n
s
t
r
u
c
t
i
o
n
a
n
d
b
e
s
o
l
e
l
y
r
e
s
p
o
n
s
ib
l
e
u
p
o
n
i
s
s
u
e
d
p
e
r
m
i
t
.
A
l
l
i
n
f
o
r
m
a
t
i
o
n
co
n
t
a
i
n
e
d
w
i
t
h
i
n
t
h
e
s
e
p
l
a
n
s
i
s
s
u
b
j
e
c
t
t
o
c
h
a
n
g
e
b
as
e
o
n
c
o
d
e
r
e
q
u
i
r
e
m
e
n
t
s
a
n
d
p
e
r
m
i
t
t
i
n
g
ju
r
i
s
d
i
c
t
i
o
n
I
n
t
e
r
p
r
e
t
a
t
i
o
n
.
Page #Page #Page #Page #
PL
A
N
S
C
A
L
E
:
BA
S
E
@
1
/
4
"
=
1
'
-
0
'
'
U.
O
.
N
.
S
C
A
L
E
M
A
Y
V
A
R
Y
P
E
R
P
L
A
N
OR
P
E
R
D
E
T
A
I
L
(
N
O
T
S
P
E
C
I
F
I
C
)
Building Code: IRC2018
Design Wind Speed: 130 mph
ASD - ASCE 7-10
Design Wind Speed: 160 MPH
Ultimate - ASCE 7-16
Req. Glazing & Door Design
Pressures (DP's) 50 psf
All Doors and Glazing Installed
shall be Impact Rated
Flood Zone: FIRM - X
Finish Floor Elevation:
Min. 36'' A.CL.RW.
Mean Roof Height:
A 1.6A 1.6A 1.6A 1.6
I,
L
a
r
r
y
M
.
O
l
i
v
e
r
,
P
.
E
.
,
L
i
c
e
n
s
e
N
o
.
1
2
6
7
8
Ce
r
t
i
f
y
t
h
a
t
t
h
e
s
t
r
u
c
t
u
r
a
l
p
o
r
t
i
o
n
s
o
f
t
h
i
s
se
t
o
f
c
o
n
s
t
r
u
c
t
i
o
n
d
o
c
u
m
e
n
t
s
h
a
v
e
b
e
e
n
re
v
i
e
w
e
d
u
n
d
e
r
m
y
r
e
s
p
o
n
s
i
b
l
e
c
h
a
r
g
e
,
de
s
i
n
a
t
e
d
b
y
d
e
s
i
g
n
,
t
o
c
o
m
p
l
y
w
i
t
h
t
h
e
en
g
i
n
e
e
r
i
n
g
r
e
q
u
i
r
e
m
e
n
t
s
o
f
t
h
e
In
t
e
r
n
a
t
i
o
n
a
l
R
e
s
i
d
e
n
t
i
a
l
B
u
i
l
d
i
n
g
C
o
d
e
,
20
1
8
L
a
t
e
s
t
E
d
i
t
i
o
n
@
1
3
0
/
1
6
0
-
m
p
h
3
se
c
g
u
s
t
w
i
n
d
l
o
a
d
r
a
t
i
n
g
.
La
r
r
y
M
.
O
l
i
v
e
r
E
n
t
e
r
p
r
i
s
e
s
I
n
c
.
72
2
8
O
a
k
b
r
i
a
r
D
r
i
v
e
S
o
u
t
h
Mo
b
i
l
e
,
A
L
.
3
6
6
1
9
PE
R
M
I
T
J
U
R
I
S
D
I
C
T
I
O
N
:
CI
T
Y
O
F
F
A
I
R
H
O
P
E
B.
F
.
E
.
:
1
2
'
'
A
.
C
L
.
R
W
FL
O
O
D
Z
O
N
E
:
"
X
"
CO
N
T
R
A
C
T
O
R
:
S
T
E
V
E
J
O
N
E
S
C
O
N
T
R
A
C
T
O
R
PR
O
J
E
C
T
:
R
E
M
O
D
E
L
S
I
N
G
L
E
F
A
M
I
L
Y
R
E
S
.
CL
I
E
N
T
:
L
U
C
I
N
D
A
&
C
H
I
P
C
H
A
P
P
E
L
L
E
LO
C
A
T
I
O
N
:
F
A
I
R
H
O
P
E
,
A
L
.
PH
Y
S
I
C
A
L
A
D
D
R
E
S
S
:
2
1
0
G
A
Y
F
E
R
C
T
.
Base Slab Elev: 24''' A.F.G. (Varies)
FINAL REVIEW - 12/04/25
PRELIM. REVIEW -09/16/25
PRELIM. REVIEW - 11/04/25
PRELIM. REVIEW - 10/07/25
PRELIM. REVIEW -09/17/25
c
2
0
2
5
C
O
P
Y
R
I
G
H
T
B
Y
K
.
A
.
T
.
D
e
s
i
g
n
s
I
n
c
.
T
h
e
s
e
d
r
a
w
i
ng
s
a
r
e
N
O
T
T
O
B
E
re
p
r
o
d
u
c
e
d
o
r
c
o
p
i
e
d
i
n
a
n
y
f
o
r
m
w
h
a
t
s
o
e
v
e
r
w
i
t
h
o
u
t
t
h
e
w
r
i
t
t
e
n
pe
r
m
i
s
s
i
o
n
o
f
K
.
A
.
T
.
D
e
s
i
g
n
s
I
n
c
.
-
A
N
Y
D
U
P
L
I
C
A
T
I
O
N
I
S
P
R
O
H
I
B
I
T
E
D
A
N
D
PU
N
I
S
H
A
B
L
E
U
N
D
E
R
F
E
D
E
R
A
L
L
A
W
.
T
h
e
p
u
r
c
h
a
s
e
r
h
a
s
t
h
e
ri
g
h
t
t
o
O
N
E
US
E
f
o
r
p
e
r
m
i
t
t
i
n
g
p
u
r
p
o
s
e
s
,
a
n
y
f
u
t
u
r
e
u
s
e
o
f
t
h
e
pl
a
n
,
i
d
e
a
s
,
e
l
e
v
a
t
i
o
n
s
,
co
n
t
e
n
t
s
,
o
r
c
h
a
n
g
e
s
t
o
d
e
s
i
g
n
a
r
e
t
h
e
p
r
o
p
e
r
t
y
o
f
K
.
A
.
T
.
D
e
s
i
g
n
s
I
n
c
.
AN
D
M
U
S
T
B
E
A
U
T
H
O
R
I
Z
E
D
B
Y
K
.
A
.
T
.
D
e
s
i
g
n
s
I
n
c
.
A
N
Y
U
NA
T
H
O
R
I
Z
E
D
U
S
E
WI
L
L
B
E
P
U
N
I
S
H
A
B
L
E
U
N
D
E
R
F
E
D
E
R
A
L
C
O
P
Y
R
I
G
H
T
L
A
W
S
.
NE
W
R
E
M
O
D
E
L
D
I
M
E
N
S
I
O
N
A
L
F
I
R
S
T
FL
O
O
R
P
L
A
N
w
/
N
O
T
E
S
&
W
/
D
S
C
H
E
D
U
E
S
FIRST FLOOR -
DIMENSIONAL
FLOOR PLAN
SCALE : 1/4'' = 1'-0''
Page 25 of 63
FULL LENGTH
WALL STUD
PACKS
TYPE CONNECTORS
REQUIRED
CRIPPLE STUDS
HEADER
TYPE "A" - SIMPSON LSTA 24'' to30''-16dA
DOUBLE TOP
PLATE
OPTIONAL CONTINUOUS CONNECTION DETAIL : STRAPPING DIAGRAM
A
NO CONNECTOR REQUIRED
TYPE "C"- SIMPSON SP6 5-8d or H 2.5
EACH TO STUDS AND TOP PLATES
TYPE "D"- SIMPSON STHD or HD5A' 1-5/8 "
BOLT TO CONCRETE, 2- 5/8" BOLTS TO
STUDS
D
C
A
D
EE
Type E = 10'' Anchor Bolts to Slab min 32'' o.c. typ.
TYP.
CONNECTORS
REQUIRED
TYPE "B"- SIMPSON H10; 6-8d EACH
TO RAFTER & TOP PLATE
B
B
BBB
C C
F
FF
F
TYPE "F"- SIMPSON SP6 5-8d OR H2.5 EACH
TO STUDS AND BOTTOM PLATES
1/2'' = 1'-0''
D D @ CORNERS@ CORNERS
USE THIS IN LUE OF GO BOLTS WHERE NECESSARY
7
A1.6
SIMPSON
STRONG TIE SP1
STUD-PLATE
TIES FASTENED
WITH (10) 0.148''
X 3'' NAILS
TOP PLATE AND BASE PLATE CON.
APPLY TO ALL NEW CONST. CON.
SIMPSON STRONG
TIE SP2 STUD-PLATE
TIES FASTENED
WITH (12) 0.148'' X 3''
NAILS
1
A1.7
(IRC- 2018 - SECTION R602.7 ) Openings In Exterior Walls:
=======================================
SEE TABLE R602.7.5 Headers: Headers shall be provided over each opening in exterior -bearing walls. The spans in
Table are permitted to be used for one- and two-family dwellings. Headers for other buildings shall be designed in
accordance with Section R602.4: R602.3.4 Item 1 or 2. Headers shall be of two pieces of nominal 2 - Inch framing
lumber use on edge as permitted by the Reference Table and nailed together in accordance with Table R602.3 (1) or
of solid lumber of equivalent size.
----------------------
Single or Double Jack Studs Number applied as per size of wall framing
130mph to150 mph (2x4 walls = 2 + trimmer - 2x6" walls = 1 + trimmer.)
Exception: 160 mph High Wind prone areas will require an additional stud
and trimmer per side of opening strapped accordingly.(2x4 walls = 3 + 2 trimmer - 2x6" walls = 2 +2 trimmer.) U.O.N.
SINGLE UNIT
OPENING NOT
SEPARATED BY
STUDS
8' TO 18'
4' TO 8'
UP TO 4'
NUMBER OF FULL
HEIGHT STUDS
NUMBER OF
JACK STUDS
15' - 18'/+
HEADER SPAN (FT)MIN. HEADER SIZE
3 - 1.75'' x 1.78'' - LVL
VERIFY w/ PLANS
10' - 14'2 - 1.75'' x 1.78'' - LVL
VERIFY w/ PLANS
3 - 2X12
2 - 2X10
2 - 2X8
2 - 2X62 - 3 FT
4 - 5 FT
8 - 9 FT
6 - 7 FT
WINDOW INSTALLATION RESPONSIBILITY - 2018 IRC SECTIONS - 308 - 310 - 311 TO INCLUDE SUB SEC.
===================================================
IT IS THE RESPONSIBILITY OF THE BUILDER/OWNER TO VERIFY THAT ALL DOOR & WINDOW GLASS AREAS COMPLY TO SECTION
R-308.4 OF THE IRC 2018 GLAZING CODE RESTRICTIONS ARTICLES 1-9 INCLUDING THE EXCEPTIONS NOTES. ALL WINDOW
PROTECTION MUST COMPLY WITH IRC SECTION R301.2.1.2 COMPONENTS AND CLADDING PRESSURE ZONES TO INCLUDE THE
EXCEPTION NOTES & TABLES REFERENCED THEREIN. BUILDER/OWNER MUST FURNISH WINDOW DATA TO BUILDING DEPT. TO
VERIFY COMPLIANCE WITHIN IRC 2018 WINDOW GUIDLINES. ALL WINDOWS MUST MEET MIN DPI 50 RATING, IMPACT RATED
WINDOWS SHALL BE INSTALLED IN THIS RESIDENCE MEETING THE 130/160 mph REQ OR PER LOCAL CODE ORD. ALL WINDOWS
SHALL BE IMPACT RATED OR BUILDER MUST PROVIDE PROTECTIVE COVERING WITHIN CODE REQ. OPTION: ( OPPERABLE
APPROVED HURRICANE TYPE PROTECTION SECURED TO STRUCTURE, ROLL DOWN SHUTTERS or 3M KEVLAR SCREEN MAY BE
USED INSTEAD OF IMPACT RATED WINDOWS. INFORMATION MUST BE PROVIDED BY BUILDER DURING CONST. OR UPON
INSPECTION ) NOTE: Windows shown, may be impact rated, and must provide 5.7 SF clear opening in sleeping rooms. All sleeping
room Windows per Schedules are sized @ MIN. 3/0-6/0 provides a min. opening of the bottom sash @ 8.25 sf. All others are to provide
an egress of a min. 36'' x 80'' door or larger exiting to the outside of the Ext. All windows within 2'-0'' of a door must be Tempered
completely.Window Fall Protection: Window openings control devices meeting ASTM2090 must be installed on all Windows that have
an opening less than 24in fron the finish floor and the opening is 72in above the exterior grade. (R312.2)
DN
W02-3050SC
D08-2868 D02-2868
D04-2868
D0
6
-
3
0
6
8
D0
1
-
2
8
6
8
D03-2868
D07-2868
W03-3056SH
W01-3048SH
D0
5
-
2
8
8
0
REF.
UP
BEDROOM #4
GUEST BATH
8' CLG
CHIPS OFFICE
LOFT / MUSIC
STUDIO AREA
w/ DBL STEP TRAY
CLG TO 9' CTR.
CLOSET
SU
P
P
L
Y
C
L
O
S
E
T
2'-4"
2'-4"
2'
-
0
"
12
'
-
4
"
2'
-
0
"
5'
-
9
"
3'
-
3
"
4'-0"
4'-11"
4'
-
4
"
16'-6"
3'-8"7'
-
4
"
8'
-
1
"
6'
-
0
"
15
'
-
5
"
6'
-
0
"
10'-7"16'-10"3'-8"
14
'
-
7
"
3'
-
1
1
"
5'-6"1'-8"2'-8"9"7'-8"6"2'-8"9'-8"
2'
-
0
"
2'
-
8
"
4'
-
4
"
2'-6"2'-8"2'-6"
5'-6"5'-1"
56
'
-
7
"
18
'
-
6
"
17
'
-
1
"
15
'
-
0
"
6'
-
0
"
8'
-
5
"
3'
-
0
"
5'
-
8
"
2'-10"
31'-1"
10'-5"20'-8"
3'-9"3'-0"13'-11"
56
'
-
7
"
6'
-
0
"
15
'
-
3
"
16
'
-
1
0
"
9'
-
0
"
9'
-
6
"
31'-1"
3'-8"16'-10"3'-0"
6'-7"3'-0"7'-3"
31'-2"
21
'
-
5
"
16
'
-
8
"
20'-0"
18
'
-
6
"
8"
2'
-
8
"
4'
-
0
"
6"2'-8"7'-3"
8"2'-8"9'-10"
3'-10"13'-2"
8'
1
'
'
W
A
L
L
H
G
T
A
T
T
H
I
S
S
I
D
E
8'
1
'
'
W
A
L
L
H
G
T
A
T
T
H
I
S
A
R
E
A
LI
N
E
O
F
8
'
V
A
L
L
E
Y
A
R
E
A
LI
N
E
O
F
8
'
C
E
I
L
I
N
G
LI
N
E
O
F
8
'
C
E
I
L
I
N
G
8' BASE HGT
8'
B
A
S
E
H
G
T
8' BASE HGT
8'
B
A
S
E
H
G
T
8' - CLG HGT
LINE OF 8'
VALLY AREA
LINE OF 8'
VALLY AREA
CE
I
L
I
N
G
S
L
O
P
E
S
WI
T
H
S
T
A
I
R
S
LIN
CAB
30'' SINK BASE
3x5 TILE
SHWR
WET BAR AREA 18
'
'
d
e
p
t
h
f
u
t
u
r
e
e
n
t
e
r
t
a
i
n
m
e
n
t
c
e
n
t
e
r
15''
DR
STK
15''
DR
STK
60'' VANITY
36
'
'
K
.
W
.
S
U
P
@
E
X
T
.
B
R
G
.
36
'
'
K
.
W
.
S
U
P
@
E
X
T
.
B
R
G
.
60
'
'
K
.
W
.
S
U
P
@
I
N
T
.
B
R
G
.
60
'
'
K
.
W
.
S
U
P
@
I
N
T
.
B
R
G
.
FLAT 8' CEILING
or VAULTED TO
RAFTER BOTTOMS
GARAGE GABLE END WALL
REF. w/ WINDOW INSERT
SLOPE TO 8'SLOPE TO 8'
SLOPE TO 8'SLOPE TO 8'
LINE OF EXTERIOR LOWER STRUCTURE GABLE OPEN FRAMED END
LI
N
E
O
F
E
X
T
E
R
I
O
R
L
O
W
E
R
S
T
R
U
C
T
U
R
E
LI
N
E
O
F
E
X
T
E
R
I
O
R
L
O
W
E
R
S
T
R
U
C
T
U
R
E
LINE OF EXTERIOR LOWER STRUCTURE
LI
N
E
O
F
E
X
T
E
R
I
O
R
L
O
W
E
R
S
T
R
U
C
T
U
R
E
8'
1
'
'
W
A
L
L
H
G
T
A
T
T
H
I
S
S
I
D
E
SLOPE
SLOPE
GARAGE GABLE END WALL REFERENCE LOCATION
8' - CLG HGT
SECOND FLOOR - INTERIOR DOOR SCHEDULE
NUMBER QTY FLOOR SIZE DIMENSIONS DESCRIPTION
D01 1 2 2868 32X80X1 3/8" BR #4 - BATH ENTRY - PANEL DR
D02 1 2 2868 L IN 32X80X1 3/4" L IN GUEST BATH - ENTRY DR. PANEL
D03 1 2 2868 L IN 32X80X1 3/8" L IN CHIPS OFFICE - ENTRY PANEL DOOR
D04 1 2 2868 R IN 32X80X1 3/8" R IN BR #4 CLOSET - PANEL DOOR
D05 1 2 2880 L IN 32X96X1 3/8" L IN OFFICE CL - PANEL DOOR
D06 1 2 3068 L EX 36X80X1 3/4" L EX ATTIC MECHANICAL ENTRY DR. -PANEL
D07 1 2 2868 R EX 32X80X1 3/4" R EX ATTIC MECHANICAL ACCESS -PANEL DR
D08 1 2 2868 R IN 32X80X1 3/8" R IN BR #4 ENTRY - PANEL DOOR
SECOND FLOOR - IMPACT RATED GLASS - EGRESS WINDOW SCHEDULE
NUMBER QTY FLOOR SIZE DIMENSIONS DESCRIPTION
W01 1 2 3048SH 36"X56"SH SINGLE HUNG
W02 1 2 3050SC 36"X60"SC SNGL CASEMENT-HR
W03 1 2 3056SH 36"X66"SH SINGLE HUNG
GENERAL FRAMING NOTES:
========================
1. ALL WOOD HEADERS AND BEAMS SHALL BE SYP #2 (OR BETTER) U.N.O.
A) 2 X 4, 2 X 6 BEARING STUD WALLS/SHEAR WALLS-STUD GRADE OR BETTER U.N.O.
B) ALL POSTS - #2 GRADE (OR BETTER) U.N.O.
C) ALL HEADERS/BEAMS #2 GRADE (OR BETTER) U.N.O.
2. ALL INTERIOR HEADERS SHALL BE AS NOTED PER CHART. U.O.N.
3. FASTENING ALL DOUBLE HEADERS TOGETHER WITH 2 ROWS OF 16D NAILS @ 16" O.C. OR THRU-BOLTED
(ALONG EA. EDGE - STAGGERED) FASTEN TRIPLE HDRS.W/2 ROWS EA. SIDE U.N.O.
4. FASTEN ALL DOUBLE LVLS TOGETHER WITH 2 ROWS OF 16D NAILS @ 12" O.C. (ALONG EA. EDGE - STAGGERED)
FASTEN TRIPLE LVLS w/ 1/2" M.B. U.N.O. @ 18" O.C. TO STAGGERED U.N.O
5. PROVIDE DOUBLE STUDS MIN. AT EACH SIDE OF ANY OPENING AND TRIPLE STUDS MIN. AT ALL CORNERS. U.N.O.
HIGH WIND HOLDDOWN
CONNECTION TYPE
PROPOSED
CONNECTOR
EQ. ALTERNATE
USE CONNECTOR
ORG. DETAIL
LOCATION
HD5BHDG 16'' HTT5 - 3/4HOLDDOWN AT ALL EXT. CORNERS -
WINDOW & DOOR OPENINGS: 1 EA SIDE 1A - A1.3
GARAGE DOOR OPENINGS: 1 @ EA SIDE STHD 24'' STHD10 or HTT5 - 3/4
STUD TO TOP & BOTTOM PLATE CON.SP1, 2, 4, or 6 - H2.5 SDWS16 3 1/2'' SCREW- 2 EA 6 A1.3 - 4 A1.6
ROOF RAFTER TO TOP PLATE CON.
CEILING JOIST TO TOP PLATE CON.
H-10 or EQ.SDWC15600 - 6'' SCREW 2 EA.
H-2.5 - LGT2 - H-10 SDWC15600 - 6'' SCREW 2 EA.
SDWS16 - 3 1/2'' SCREW (6'' O.C)EXT. SHEAR WALL SHEATHING CONT. CON.CS52,LSTA-36
HEADER TO STUD PACK CONNECTION LSTA 24 - 32''CMST - 27" or SDWS16300 (6''O.C.)
CMST52, MSTI 24" THRU 60"
STUD TO FLOOR JOIST/FLR TRUSS TO STUD CON.LSTA - 36 CMST52, MSTI 24" THRU 60"
SDWC15450 - 4 1/2'' SCREW (6'' O.C)
INTERIOR WALL TO GRADE BEAM CON 5/8'' x 10'' AB @
32''O.C.
2 PLY 2x12 LEDGER TO WALL FRAMING CON.SDWS22800DB- R50 8''
SCREWS @ 6''O.C. SP.
Titen HD- Screw Anchor Type - 316
THDB62500H6SS (5/8'' x 5'')
EXT. SHEAR WALL SHEATHING: PLAN USE ALTERNATES -15/32" ZIP PANELS or 7/16'' APA RATED SHEAR 4 PLY WOOD
EXT. SHEATHING or 7/16 NORBOARD HIGHWIND RATED SHEATHING or 5/8'' APA RATED OSB EXT. SHEATHING
3 A 1.3
8 A 1.4LB-LAG SCREWS
VALLEY RAFTER TO ROOF RAFTER CON SDWS16 - 3 1/2'' SCREW (6'' O.C)7 A 1.616d 3'' NAILS @ 6'' O.C.
CEILING JOIST TO LVL BEAM CON.SDWC15600 - 6'' SCREW 2 EA.LUS26 or EQ.6 A 1.5
1 A 1.6
5 A 1.5
2 A 1.4
7 A 1.5
1 & 2 A 1.4
GIRDER TRUSS TO TOP PLATE CON.LGT2-2 SDWS16 - 3 1/2'' SCREW (6'' O.C)6 A 1.6
1 A1.3
PRINT DATES
FINAL PRINT - 12/09/25
DESIGN DRAWN BY
Kirk A. ThomasKirk A. ThomasKirk A. ThomasKirk A. Thomas
To
t
h
e
b
e
s
t
o
f
m
y
k
n
o
w
l
e
d
g
e
t
h
e
s
e
p
l
a
n
s
a
r
e
d
r
a
w
n
t
o
c
o
m
p
l
y
w
i
t
h
t
h
e
c
o
d
e
r
e
q
u
i
r
e
m
e
n
t
s
f
o
r
th
e
i
r
i
n
t
e
n
d
e
d
u
s
e
b
y
o
w
n
e
r
'
s
a
n
d
/
o
r
b
u
i
l
d
e
r
'
s
s
p
e
c
if
i
c
a
t
i
o
n
s
,
a
n
y
c
h
a
n
g
e
s
m
a
d
e
o
n
o
r
t
o
t
h
e
m
af
t
e
r
p
r
i
n
t
s
a
r
e
s
e
a
l
e
d
w
i
l
l
b
e
d
o
n
e
a
t
t
h
e
o
w
n
e
r
'
s
a
n
d
/
o
r
b
u
i
l
d
e
r
'
s
e
x
p
e
n
c
e
a
n
d
r
e
s
p
o
n
s
i
b
i
l
i
t
y
.
Th
e
c
o
n
t
r
a
c
t
o
r
s
h
a
l
l
v
e
r
i
f
y
a
l
l
d
i
m
e
n
s
i
o
n
s
a
n
d
e
n
c
l
os
e
d
d
e
t
a
i
l
d
r
a
w
i
n
g
s
.
R
e
f
e
r
I
n
s
t
a
l
l
a
t
i
o
n
o
f
a
l
l
ma
t
e
r
i
a
l
s
t
o
m
a
n
u
f
a
c
t
u
r
e
s
a
n
d
c
o
d
e
r
e
q
u
i
r
m
e
n
t
s
f
o
r
ea
c
h
i
t
e
m
s
a
t
t
a
c
h
m
e
n
t
t
o
t
h
e
s
t
r
u
c
t
u
r
e
re
q
u
a
r
d
l
e
s
s
o
f
d
e
t
a
i
l
s
h
o
w
n
.
D
e
t
a
i
l
s
a
r
e
n
o
t
s
p
e
c
i
fi
c
t
o
s
t
r
u
c
t
u
r
e
d
r
a
w
n
,
d
e
t
a
i
l
s
a
r
e
d
r
a
w
n
a
s
pe
r
s
p
e
c
t
i
v
e
c
u
t
a
w
a
y
v
i
e
w
s
a
n
d
i
n
n
o
w
a
y
s
h
o
w
m
a
t
e
r
i
al
i
t
e
m
s
a
s
f
i
n
i
s
h
e
d
i
n
s
t
a
l
l
e
d
re
p
r
e
s
e
n
t
a
t
i
o
n
.
k
.
a
.
t
.
D
e
s
i
g
n
s
I
n
c
.
i
s
n
o
t
l
i
a
b
l
e
f
or
e
r
r
o
r
s
b
a
s
e
d
u
p
o
n
p
e
r
s
o
n
a
l
i
n
t
e
r
p
r
e
t
a
t
i
o
n
of
a
n
y
d
e
t
a
i
l
,
t
e
x
t
i
t
e
m
,
o
r
s
y
m
b
o
l
u
s
e
d
i
n
t
h
e
c
r
e
at
i
o
n
o
f
t
h
e
s
e
d
o
c
u
m
e
n
t
s
.
W
h
i
l
e
e
v
e
r
y
e
f
f
o
r
t
ha
s
b
e
e
n
m
a
d
e
i
n
t
h
e
p
r
e
p
a
r
a
t
i
o
n
o
f
t
h
i
s
p
l
a
n
t
o
a
v
oi
d
m
i
s
t
a
k
e
s
,
t
h
e
m
a
k
e
r
c
a
n
n
o
t
g
u
a
r
a
n
t
e
e
ag
a
i
n
s
t
h
u
m
a
n
e
r
r
o
r
.
T
h
e
L
i
c
.
C
o
n
t
r
a
c
t
o
r
/
O
w
n
e
r
s
o
f
th
e
p
r
o
j
e
c
t
m
u
s
t
c
h
e
c
k
a
l
l
d
i
m
e
n
s
i
o
n
s
a
n
d
de
t
a
i
l
s
p
r
i
o
r
t
o
c
o
n
s
t
r
u
c
t
i
o
n
a
n
d
b
e
s
o
l
e
l
y
r
e
s
p
o
n
s
ib
l
e
u
p
o
n
i
s
s
u
e
d
p
e
r
m
i
t
.
A
l
l
i
n
f
o
r
m
a
t
i
o
n
co
n
t
a
i
n
e
d
w
i
t
h
i
n
t
h
e
s
e
p
l
a
n
s
i
s
s
u
b
j
e
c
t
t
o
c
h
a
n
g
e
b
as
e
o
n
c
o
d
e
r
e
q
u
i
r
e
m
e
n
t
s
a
n
d
p
e
r
m
i
t
t
i
n
g
ju
r
i
s
d
i
c
t
i
o
n
I
n
t
e
r
p
r
e
t
a
t
i
o
n
.
Page #Page #Page #Page #
PL
A
N
S
C
A
L
E
:
BA
S
E
@
1
/
4
"
=
1
'
-
0
'
'
U.
O
.
N
.
S
C
A
L
E
M
A
Y
V
A
R
Y
P
E
R
P
L
A
N
OR
P
E
R
D
E
T
A
I
L
(
N
O
T
S
P
E
C
I
F
I
C
)
Building Code: IRC2018
Design Wind Speed: 130 mph
ASD - ASCE 7-10
Design Wind Speed: 160 MPH
Ultimate - ASCE 7-16
Req. Glazing & Door Design
Pressures (DP's) 50 psf
All Doors and Glazing Installed
shall be Impact Rated
Flood Zone: FIRM - X
Finish Floor Elevation:
Min. 36'' A.CL.RW.
Mean Roof Height:
A 1.7A 1.7A 1.7A 1.7
I,
L
a
r
r
y
M
.
O
l
i
v
e
r
,
P
.
E
.
,
L
i
c
e
n
s
e
N
o
.
1
2
6
7
8
Ce
r
t
i
f
y
t
h
a
t
t
h
e
s
t
r
u
c
t
u
r
a
l
p
o
r
t
i
o
n
s
o
f
t
h
i
s
se
t
o
f
c
o
n
s
t
r
u
c
t
i
o
n
d
o
c
u
m
e
n
t
s
h
a
v
e
b
e
e
n
re
v
i
e
w
e
d
u
n
d
e
r
m
y
r
e
s
p
o
n
s
i
b
l
e
c
h
a
r
g
e
,
de
s
i
n
a
t
e
d
b
y
d
e
s
i
g
n
,
t
o
c
o
m
p
l
y
w
i
t
h
t
h
e
en
g
i
n
e
e
r
i
n
g
r
e
q
u
i
r
e
m
e
n
t
s
o
f
t
h
e
In
t
e
r
n
a
t
i
o
n
a
l
R
e
s
i
d
e
n
t
i
a
l
B
u
i
l
d
i
n
g
C
o
d
e
,
20
1
8
L
a
t
e
s
t
E
d
i
t
i
o
n
@
1
3
0
/
1
6
0
-
m
p
h
3
se
c
g
u
s
t
w
i
n
d
l
o
a
d
r
a
t
i
n
g
.
La
r
r
y
M
.
O
l
i
v
e
r
E
n
t
e
r
p
r
i
s
e
s
I
n
c
.
72
2
8
O
a
k
b
r
i
a
r
D
r
i
v
e
S
o
u
t
h
Mo
b
i
l
e
,
A
L
.
3
6
6
1
9
PE
R
M
I
T
J
U
R
I
S
D
I
C
T
I
O
N
:
CI
T
Y
O
F
F
A
I
R
H
O
P
E
B.
F
.
E
.
:
1
2
'
'
A
.
C
L
.
R
W
FL
O
O
D
Z
O
N
E
:
"
X
"
CO
N
T
R
A
C
T
O
R
:
S
T
E
V
E
J
O
N
E
S
C
O
N
T
R
A
C
T
O
R
PR
O
J
E
C
T
:
R
E
M
O
D
E
L
S
I
N
G
L
E
F
A
M
I
L
Y
R
E
S
.
CL
I
E
N
T
:
L
U
C
I
N
D
A
&
C
H
I
P
C
H
A
P
P
E
L
L
E
LO
C
A
T
I
O
N
:
F
A
I
R
H
O
P
E
,
A
L
.
PH
Y
S
I
C
A
L
A
D
D
R
E
S
S
:
2
1
0
G
A
Y
F
E
R
C
T
.
Base Slab Elev: 24''' A.F.G. (Varies)
FINAL REVIEW - 12/04/25
PRELIM. REVIEW -09/16/25
PRELIM. REVIEW - 11/04/25
PRELIM. REVIEW - 10/07/25
PRELIM. REVIEW -09/17/25
c
2
0
2
5
C
O
P
Y
R
I
G
H
T
B
Y
K
.
A
.
T
.
D
e
s
i
g
n
s
I
n
c
.
T
h
e
s
e
d
r
a
w
i
ng
s
a
r
e
N
O
T
T
O
B
E
re
p
r
o
d
u
c
e
d
o
r
c
o
p
i
e
d
i
n
a
n
y
f
o
r
m
w
h
a
t
s
o
e
v
e
r
w
i
t
h
o
u
t
t
h
e
w
r
i
t
t
e
n
pe
r
m
i
s
s
i
o
n
o
f
K
.
A
.
T
.
D
e
s
i
g
n
s
I
n
c
.
-
A
N
Y
D
U
P
L
I
C
A
T
I
O
N
I
S
P
R
O
H
I
B
I
T
E
D
A
N
D
PU
N
I
S
H
A
B
L
E
U
N
D
E
R
F
E
D
E
R
A
L
L
A
W
.
T
h
e
p
u
r
c
h
a
s
e
r
h
a
s
t
h
e
ri
g
h
t
t
o
O
N
E
US
E
f
o
r
p
e
r
m
i
t
t
i
n
g
p
u
r
p
o
s
e
s
,
a
n
y
f
u
t
u
r
e
u
s
e
o
f
t
h
e
pl
a
n
,
i
d
e
a
s
,
e
l
e
v
a
t
i
o
n
s
,
co
n
t
e
n
t
s
,
o
r
c
h
a
n
g
e
s
t
o
d
e
s
i
g
n
a
r
e
t
h
e
p
r
o
p
e
r
t
y
o
f
K
.
A
.
T
.
D
e
s
i
g
n
s
I
n
c
.
AN
D
M
U
S
T
B
E
A
U
T
H
O
R
I
Z
E
D
B
Y
K
.
A
.
T
.
D
e
s
i
g
n
s
I
n
c
.
A
N
Y
U
NA
T
H
O
R
I
Z
E
D
U
S
E
WI
L
L
B
E
P
U
N
I
S
H
A
B
L
E
U
N
D
E
R
F
E
D
E
R
A
L
C
O
P
Y
R
I
G
H
T
L
A
W
S
.
SECOND FLOOR - FLOOR PLAN - ATTIC UNDER ROOF AREA
SCALE : 1/4'' = 1'-0''
NE
W
R
E
M
O
D
E
L
D
I
M
E
N
S
I
O
N
A
L
2
N
D
FL
O
O
R
P
L
A
N
w
/
N
O
T
E
S
&
W
/
D
S
C
H
E
D
U
E
S
Page 26 of 63
CONSTRUCTION NOTES:
====================
1) THE FINISHED FLOOR ELEVATION SHALL BE AS REQUIRED BY CODES, AND TO PROVIDE THE PROPER ELEVATION FOR APPLICABLE FLOOD ZONES.
2) THE FINISHED FLOOR ELEVATION SHALL BE DETERMINED BY A REGISTERED ENGINEER OR LAND SURVEYOR.
3) FACE DIMENSIONS ARE TO OUTSIDE EDGE OF STUD WALL FRAMING UNLESS OTHERWISE NOTED.
4) ALLOWABLE SOIL BEARING COMPACTION TO BE 1500 PSI MIN.
5) CONCRETE SHALL DEVELOP 3000 PSF MI. COMPRESSIVE STRENGTH IN 28 DAYS.
6) ALL FOOTINGS SHALL EXTEND 12" MIN. INTO COMPACTED SAND.
7) CONTRACTOR SHALL VERIFY FOOTING SIZE w/ SITE AND SOIL CONDITIONS PRIOR TO CONSTRUCTION.
8) STEP ALL PORCHES AND DECKS DOWN MIN. 4" FROM THE FINISHED FLOOR ELEVATION.
9) VERIFY LOCATION OF PLUMBING FIXTURES, CONDUITS, AND ALL ITEMS EMBEDDED IN CONCRETE.
10) PROVIDE AND INSTALL ALL STEEL REINFORCING BARS, DOWLELS, TIES, AND OTHER ITEMS EMBEDDED IN CONCRETE.
11) UNDERSLAB VAPOR BARRIER SHALL BE 6 MIL. POLYETHYLENE MEMBRANE, OR EQUAL. LAP AS REQUIRED AT JOINTS AND SEAL.
12) THE GARAGE DOOR TO HOUSE MUST BE SELF- CLOSING, AND EITHER A 20 MINUUTE FIRE RATED DOOR, A 1 3/8'' SOLID WOOD DOOR, OR SOLID OR HONEYCOMB
STEEL DOOR PER R302.5.1, IF SHOWN ON PLANS.
13) THE GARAGE OR ENTRY AREA BELOW MAIN STRUCTURE SHALL BE SEPARATED FROM THE HOUSE AND ATTIC OR FLOOR LOCATED ABOVE BY NOT LESS THAN
1/2'' GYPSUM BOARD PER SECTION R302.6 2018 IRC.
14 ) IMPACT RATED WINDOWS AND DOORS MAY BE REQUIRED FOR THIS STRUCTURE - PROVIDED BY OWNER WINDBORNE DEBRIS PROTECTION DETAILS FOR
GLAZED OPENINGS - INCLUDING DESIGN/ KEVELAR CLOTH, PROTECTION IF DESIRED USE. ALSO PROVIDED PRESSURE RATINGS, AND OPENING PROTECTION IMPACT
RATING PER COASTAL SUPPLIMENTS. (OWNER PROVIDED WINDOW STICKER INFORMATION AND INSTALLATION DOCUMENTS )
15) OWNER AND CONTRACTOR TO VERIFY ALL CONDITIONS AND DIMENSIONS PRIOR TO CONSTRUCTION.
16) AN ONSITE INVESTIGATION WAS PERFORMED BY THE DESIGNER & ENGINEER, ALL SITE INFORMATION WAS PROVIDED BY OWNER.
SHEARWALL SHEATHING:
---------------------------------------------------------------
#1 - NORBOARD - HIGH WIND RESISTANCE ENGINEERED SHEATHING SHALL BE USED AS STRUCTURAL PANELS FOR SHEAR WALL
APPLICATIONS USED ON ALL EXTERIOR AND INTERIOR SHEAR REQUIRED WALL SECTIONS. THIS MAY BE USED IN LIEU OF STRAPPING.
(SEE SPECIAL NOTE.)
#2 - ALL SHEATHING SHALL BE ATTACHED TO FRAMING ALONG ALL FOUR EDGES WITH JOINTS FOR ADJACENT PANELS OCCURING
OVER COMMON FRAMING MEMBERS OR ALONG BLOCKING.
2a. OVERLAPING OF FLOOR CONNECTIONS AT EXTERIOR WALL MIN 50% OF EACH FOR COVERAGE AT THE JOINT. NAIL PER
REQUIREMENTS IN SPECIAL NOTE.
#3 - SHEATHING MUST BE ATTACHED TO THE TOP MEMBER OF THE DOUBLE TOP PLATES.
#4 - ALL NAILS SHALL BE COMMON OR HOT DIPPED GALVANIZED BOXED NAILS.
#5 - THE ALLOWABLE SHEAR CAPACITY OF SHEARWALL SEGMENTS SHEATHED WITH A COMBINATION OF WOOD STRUCTURAL PANELS
AND GYPSUM WALL BOARD ON OPPOSITE SIDES SHALL EQUAL THE SUM OF THE SHEAR CAPACITIES OF EACH SIDE SEPERATELY
PROVIDED THE WALL IS CONSTRUCTED IN ACCORDANCE WITH THE FOLLOWING PHYSICAL LIMITATIONS:
A: FOR TYPE I WALLS , THE MIN. LENGTH OF A SHEARWALL SEGMENT SHALL BE 50% IF ITS HEIGHT.
B: FOR TYPE II WALLS, THE MIN. LENGTH OF FULL HEIGHT SHEATHING SHALL BE 50% OF ITS HEIGHT.
SPECIAL NOTE:
The use of Norboard wood structural panels, are required to resist lateral loads and normal wind load requirements of the IRC 2018
(Sections 6.4.2.2 of ASCE-7-16) or (R301.2.1, ) additional wind up lift resistance from the panel can be achieved by providing additional
nails to the shear nailing at the top and bottom of the panel. These additional nails are used to transfer the uplift forces from the top
plate to the panel, from the panel to panel at splice locations (if present) and from panel to sill plate at the foundation or floor level
connection, effectively eliminating the need for uplift straps at these locations. Uplift straps may still be required around window and
door openings in exterior walls to transfer the wind uplift loads acting on the header to the foundation or floor level connection.
SHEAR
WALL
SHEARWALL SHEATHING NAILING PATTERN APPLIED
PER 2018 IRC CODE REQUIREMENTS N.T.S.
4"
3/4"
3/8"
VERTICAL JOINT
SEE DETAIL
BASE PLATE
SEE FLOOR PLAN FOR
SHEARWALL SECTION
& LENGTH
8d NAILS @ 4" O.C.
SHEARWALL
HGT = FLOOR
TO T/PLATE
8 RS NAILS
@ 4" O.C.
EDGES
BLOCKING TO BE
COMPLETED IF NEEDED
OR AS REQUIRED BY
LOCAL CODE REQ.
2" X 6" STUDS @ 16" O.C
2" X4'' STUDS @ 16" O.C.
(EXTERIOR or INTERIOR LOC)
DBL. TOP PLATE
7/16" WINDSTORM or 5/8''
APA RATED SHEATHING
PER - IRC 2018 REQ.
NOTE: ALL EXTERIOR WALLS SHALL BE TREATED AS SHEAR
WALLS IN WIND RATED AREAS OF 130-160 mph WITH 3 SEC
WIND GUST RATINGS. (SEE PLAN FOR RATING)
SEE SHEAR WALL
INSTALLATION
NOTES SAME PAGE
6"@ CENTER
STUDS
BUILDING CODE REQUIREMENTS:
----------------------------------------------------------
1. All work, materials and installation shall be in strict accordance with all ordinances, State and Local
Building codes, OSHA Regulations, and 2018 IRC. the current National Electric 2017, to include IRC 2018
Electrical sections IRC-E309.1.2.1-E3901.4, E309.1.10, Building code for reinforcing Concrete (See
Structural) Building code for Masonary Structures (See Structural) The wood framed Construction
Manual, Current Edition, & the APA Plywood Design Specifications Manual, Current Edition.
2. See Signed and Sealed Plan drawings for all Structural Requirements.
3. The Mechanical, Electrical and Plumbing Sub- Contractors are responsible for compliance w/ all
respective codes affecting thier trade. Any MPE data on these plans are for placement only & have not
been Engineered by the Engineer of Record or reviewed against the applicable code.
DOOR & WINDOW NOTES:
=======================
1. CONTRACTOR TO PROVIDE SHOP DRAWINGS FOR ALL DOORS & WINDOWS.
2. ALL EXTERIOR DOORS TO BE CONSTRUCTED AS ALUMINUM CLAD WOOD, WITH WOOD JAMBS & EXTERIOR THRESHOLDS WOOD TO BE SPANISH
CEDAR OR MAHOGANY.
3. ALL EXTERIOR DOORS WITH GLASS TO BE IN CONFIGURATION SHOWN WITH IMPACT RATED INSULATED, TEMPERED & LOW - E CLEAR GLAZING & AS
REQUIRED BY CODES.
4. ALL WINDOWS TO BE PRE- FINISHED ALUMINUM OR VINYL CLAD EXTERIOR WITH WOOD INTERIOR. EXTERIOR COLOR TO BE SELECTED BY
OWNERS.
5. ALL WINDOWS TO BE IN CONFIGURATION SHOWN WITH IMPACT RATED (INSULATED, TEMPERED & LOW - E CLEAR) GLAZING AS REQUIRED BY
CODES.
6. ALL WINDOW DIMENSIONS SHOWN ARE FOR CLEAR OPENINGS AND NOT THE REQUIRED ROUGH OPENING REQUIREMENT FOR FRAMING REFER TO
MANUFACTURERS DRAWINGS FOR ROUGH OPENING DIMENSIONS FOR FRAMING WINDOW OPENINGS.
7. WINDOW SIZES ARE NON SPECIFIC TO A MANUFACTURER . CONTRACTOR TO PRICE CLOSEST SIZE PROVIDED BY PURCHASING MANUFACTURER
STANDARD DIMENSIONS. ANY DEVIATION IN SIZE NOT SHOWN ON DRAWINGS MUST BE SAME OR LARGER BY A MIN OF 2" IN HEIGHT AND WIDTH OR
APPROVED BY OWNERS AS A REPLACEMENT OF ORIGINAL SHOWN IN PLANS.
8. MULIPLE WINDOW CONFIGURATIONS ARE TO BE FACTORY MULLED WHERE POSSIBLE. EXCEPTION - BUILDER TO SHALL SPACE A MIN. 2 @ 2x STUD
SEPARATIONS BETWEEN EACH WINDOW SECTION.
9. OWNERS OPTION: HURRICANE PROTECTION TO BE PROVIDED TO EACH DOOR & WINDOW IN LIEU OF IMPACT GLAZING: PLYWOOD CUT TO FIT EACH
OPENING LABELED ACCORDINGLY & STORED ON SITE. PROVIDE PRICING DEDUCT FOR IMPACT RATED GLASS, AS REQUIRED BY LOCAL CODES.
10. SEE FLOOR PLANS FOR ALL OPERABLE WINDOW LOCATIONS.
11. ALL INTERIOR GLAZING IN BATHROOMS & SHOWERS TO BE TEMPERED AS REQUIRED BY CODES.
LTS
20
6"5'-0"5'-0"6"5'-0"6"8'-10"6"5'-0"
6'
-
3
"
9'
-
5
"
27
'
-
3
"
6'
-
3
"
10
'
-
5
"
10
'
-
7
"
8'
-
1
0
"
4x6'' POST
UPRIGHT
SUPPORTS
4x6'' POST
UPRIGHT
SUPPORTS
4x6''
COLAR TIE
4x6'' RAFTER @
GABLE END
4x6'' RAFTER @
GABLE END
3 PLY 1.78'' x 11.78'' LVL BEAM WRAPPED EXT
12'' PT TIMBER COL w/ HARDIE WRAP EXT FIN.
1x PT TRIM @ TOP & BOTTOM
ABU1212Z POST
BASE TO SLAB CON.ABU1212Z POST
BASE TO SLAB CON.36''
Rail Hgt
S.S. CABLE RAILING @ EXT EDGE S.S. CABLE RAILING @ EXT EDGES.S. CABLE RAILING @ EXT EDGE
4'' CONC FIN SLAB w/8'' CMU BLOCK STEM WALL @ MAX
72'' HGT F.G E. w/ COMPACT FILL MIN. 2500 PSF TYP T.O.
- EXT FIN. w/ BRICK TO MATCH EXISTING
STAIRS TO GRADE
BY BUILDER
w/ BRICK VENEER
PC
1
PC
1
PC
1
PC
1
12
8
8
12
F.G.E.
T.O.B.
F.S.E.
HE
I
G
H
T
V
A
R
I
E
S
B
A
S
E
D
ON
S
L
O
P
E
O
F
G
R
A
D
E
2 PLY 1.78'' x 11.78'' LVL RIDGE BEAM OPEN VAULTED CEILING TO UNDERSIDE OF
ROOF AREA. BUILDER TO USE 2x10''
RAFTERS @ 16'' O.C. TYP THRU OUT
EXCEPT @ GABLE END USE 4X6s
1x6 T&G STAINED FIN CLG.
PC
2
PC
2
PC
2
PC
2
R
36
R
36
2x6'' RAFTERS w/ 2x8'' CLG
JOIST @ 16'' O.C.
19/32" PLYWOOD
SHEATHING
26g METAL ROOFING
SHINGLES
INSTALL H-10 or EQUAL
VALUE ANCHOR FROM
TOP OF BOTTOM PLT OF
TOP PLT WALL SECTION
AS SHOWN (ANCHOR
(MIN.) @ EA STUD TYP.
PER CODE
R-48 SPRAY FOAM IN RAFTERS
PT2X6 TRIM(S) ON
CONTINUOUS 2X
CONT. SOFFIT VENT
INSTALL NET FREE AREA
PER UBC SEC.1505.3
5/8" PLAIN R/S FLUSH
HARDIE SOFFIT
2X4 SPACED PER RAFTER
CONT. 2X4 LEDGER
A
6 BOXED EAVE @ STANDARD TRUSS CON.
16'' O.H.
8/12
2 PLY 2X4'' &
6'' TOP PLATE
JOINT DESCRIPTION
ROOF FRAMING
Blocking to Rafter (Toe-nailed)
Rim Board to Rafter (End-nailed)
Rafter or roof truss to plate (Toe-nailed)
WALL FRAMING
Top Plates at Intersections (Face-nailed)
Stud to Stud (Face-nailed)
Header to Header (Face-nailed)
Built up studs (Face nailed)
Abutting studs @ intersecting wall corners (Face
nailed)
Built up header, two pieces w/ 1/2" spacer
FLOOR FRAMING
Joist to Sill, Top Plate or Girder (Toe Nailed)
Blocking to Joist (Toe-nailed)
Blocking to Sill or Top Plate (Toe-nailed)
Ledger strip to Beam or Girder (Face-nailed)
Joist on Ledger to Beam (Toe-nailed)
Band Joist to Joist (End-nailed)
Band Joist to Sill or Top Plate (Toe-nailed)
Rim joist to top plate (Toe-nailed)
Rim joist or blocking to sill plate (Toe-nailed)
1"x6" subfloor or less to each joist (Face-nailed)
ROOF SHEATHING
Wood Structural Panels
rafters or trusses spaced up to 16" o.c.
rafters or trusses spaced over 16" o.c.
gable endwall rake or rake truss w/o gable
overhang
gable endwall rake or rake truss w/ structural
outlookers
gable endwall rake or rake truss w/ lookout blocks
CEILING SHEATHING
Gypsum Wallboard
WALL SHEATHING
Wood Structural Panels
studs spaced up to 16" o.c.
studs spaced over 16" o.c.
25/32" Fiberboard Panels
1/2" Gypsum Wallboard
FLOOR SHEATHING
Wood Structural Panels
1" or less
greater than 1"
NAILING SCHEDULE
# of Common Nails
2-8d
2-16d
3-10d
4-16d
16d
16d
10d
16d
16d
4-8d
2-8d
3-16d
3-16d
3-8d
3-16d
2-16d
8d
8d
2-8d
8d
8d
8d
8d
8d
5d coolers
8d
8d
8d
5d coolers
8d
10d
# of Box Nails
2-10d
3-16d
3-16d
5-16d
16d
16d
10d
16d
16d
4-10d
2-10d
4-16d
4-16d
3-10d
4-16d
3-16d
8d
8d
2-8d
10d
10d
10d
10d
8d
-
10d
10d
-
-
10d
16d
Nail Spacing
each end
each end
2 toe nails on 1 side
(1 on other per rafter)
at joints
24" o.c.
16" o.c. along edges
24" o.c.
12" o.c.
16" o.c. along edges
per joist
each end
each blocks
each joist
per joist
per joist
per foot
6" o.c.
6" o.c.
----
6" edge/6" field
4" edge/4" field
4" edge/4" field
4" edge/4" field
3" edge/3" field
7" edge/10" field
6" edge/6" field
6" edge/6" field
3" edge/6" field
7"edge/10" field
6" edge/12" field
6" edge/6" field
IRREGULAR SHANK NAILS REQUIRED
IRREGULAR SHANK NAILS REQUIRED
7 10"4
INTERIOR STAIR - RAILING & BALLUST DETAILS - NOT TO SCALE
(7"TYP)
(10 1/4" TYP)
16'' FLOOR
JOIST @ 16" O.C.
2x2 BALLUST @ 5" O.C.
MIN. (IF EXPOSED)
RAILING 50% OF WALL
2'' WD- RAILING - SEE
OWNER/BUILDER FOR
SPECIFIC USE. @
EACH WALL
2x12 SYP
UNDERCARRIGE
3/4" T&G
2X10'' or 12" WD. TREADS
WD RISERS
36''
hgt
2x4'' @ 16'' o.c. FRAME
SUPPPORT w/ 1/2'' GYPSUM BD.
- SMOOTH - PAINTED FINISH
36''
2"
3"
CABLE
post
POST
MOUNT
1"
1"
INTERMEDIATE POSTS
STAINLESS STEEL CABLE & BASE PLATE ASSEMBLY FOR WD DECK
48''
TOP VIEW OF POST
2''
2'
'
TOP VIEW
PROFILE VIEW
4''
4'
'
OVER VIEW
INSTALLED SECTION
PROFILE VIEW
R
36
PRINT DATES
FINAL PRINT - 12/09/25
DESIGN DRAWN BY
Kirk A. ThomasKirk A. ThomasKirk A. ThomasKirk A. Thomas
To
t
h
e
b
e
s
t
o
f
m
y
k
n
o
w
l
e
d
g
e
t
h
e
s
e
p
l
a
n
s
a
r
e
d
r
a
w
n
t
o
c
o
m
p
l
y
w
i
t
h
t
h
e
c
o
d
e
r
e
q
u
i
r
e
m
e
n
t
s
f
o
r
th
e
i
r
i
n
t
e
n
d
e
d
u
s
e
b
y
o
w
n
e
r
'
s
a
n
d
/
o
r
b
u
i
l
d
e
r
'
s
s
p
e
c
if
i
c
a
t
i
o
n
s
,
a
n
y
c
h
a
n
g
e
s
m
a
d
e
o
n
o
r
t
o
t
h
e
m
af
t
e
r
p
r
i
n
t
s
a
r
e
s
e
a
l
e
d
w
i
l
l
b
e
d
o
n
e
a
t
t
h
e
o
w
n
e
r
'
s
a
n
d
/
o
r
b
u
i
l
d
e
r
'
s
e
x
p
e
n
c
e
a
n
d
r
e
s
p
o
n
s
i
b
i
l
i
t
y
.
Th
e
c
o
n
t
r
a
c
t
o
r
s
h
a
l
l
v
e
r
i
f
y
a
l
l
d
i
m
e
n
s
i
o
n
s
a
n
d
e
n
c
l
os
e
d
d
e
t
a
i
l
d
r
a
w
i
n
g
s
.
R
e
f
e
r
I
n
s
t
a
l
l
a
t
i
o
n
o
f
a
l
l
ma
t
e
r
i
a
l
s
t
o
m
a
n
u
f
a
c
t
u
r
e
s
a
n
d
c
o
d
e
r
e
q
u
i
r
m
e
n
t
s
f
o
r
ea
c
h
i
t
e
m
s
a
t
t
a
c
h
m
e
n
t
t
o
t
h
e
s
t
r
u
c
t
u
r
e
re
q
u
a
r
d
l
e
s
s
o
f
d
e
t
a
i
l
s
h
o
w
n
.
D
e
t
a
i
l
s
a
r
e
n
o
t
s
p
e
c
i
fi
c
t
o
s
t
r
u
c
t
u
r
e
d
r
a
w
n
,
d
e
t
a
i
l
s
a
r
e
d
r
a
w
n
a
s
pe
r
s
p
e
c
t
i
v
e
c
u
t
a
w
a
y
v
i
e
w
s
a
n
d
i
n
n
o
w
a
y
s
h
o
w
m
a
t
e
r
i
al
i
t
e
m
s
a
s
f
i
n
i
s
h
e
d
i
n
s
t
a
l
l
e
d
re
p
r
e
s
e
n
t
a
t
i
o
n
.
k
.
a
.
t
.
D
e
s
i
g
n
s
I
n
c
.
i
s
n
o
t
l
i
a
b
l
e
f
or
e
r
r
o
r
s
b
a
s
e
d
u
p
o
n
p
e
r
s
o
n
a
l
i
n
t
e
r
p
r
e
t
a
t
i
o
n
of
a
n
y
d
e
t
a
i
l
,
t
e
x
t
i
t
e
m
,
o
r
s
y
m
b
o
l
u
s
e
d
i
n
t
h
e
c
r
e
at
i
o
n
o
f
t
h
e
s
e
d
o
c
u
m
e
n
t
s
.
W
h
i
l
e
e
v
e
r
y
e
f
f
o
r
t
ha
s
b
e
e
n
m
a
d
e
i
n
t
h
e
p
r
e
p
a
r
a
t
i
o
n
o
f
t
h
i
s
p
l
a
n
t
o
a
v
oi
d
m
i
s
t
a
k
e
s
,
t
h
e
m
a
k
e
r
c
a
n
n
o
t
g
u
a
r
a
n
t
e
e
ag
a
i
n
s
t
h
u
m
a
n
e
r
r
o
r
.
T
h
e
L
i
c
.
C
o
n
t
r
a
c
t
o
r
/
O
w
n
e
r
s
o
f
th
e
p
r
o
j
e
c
t
m
u
s
t
c
h
e
c
k
a
l
l
d
i
m
e
n
s
i
o
n
s
a
n
d
de
t
a
i
l
s
p
r
i
o
r
t
o
c
o
n
s
t
r
u
c
t
i
o
n
a
n
d
b
e
s
o
l
e
l
y
r
e
s
p
o
n
s
ib
l
e
u
p
o
n
i
s
s
u
e
d
p
e
r
m
i
t
.
A
l
l
i
n
f
o
r
m
a
t
i
o
n
co
n
t
a
i
n
e
d
w
i
t
h
i
n
t
h
e
s
e
p
l
a
n
s
i
s
s
u
b
j
e
c
t
t
o
c
h
a
n
g
e
b
as
e
o
n
c
o
d
e
r
e
q
u
i
r
e
m
e
n
t
s
a
n
d
p
e
r
m
i
t
t
i
n
g
ju
r
i
s
d
i
c
t
i
o
n
I
n
t
e
r
p
r
e
t
a
t
i
o
n
.
Page #Page #Page #Page #
PL
A
N
S
C
A
L
E
:
BA
S
E
@
1
/
4
"
=
1
'
-
0
'
'
U.
O
.
N
.
S
C
A
L
E
M
A
Y
V
A
R
Y
P
E
R
P
L
A
N
OR
P
E
R
D
E
T
A
I
L
(
N
O
T
S
P
E
C
I
F
I
C
)
Building Code: IRC2018
Design Wind Speed: 130 mph
ASD - ASCE 7-10
Design Wind Speed: 160 MPH
Ultimate - ASCE 7-16
Req. Glazing & Door Design
Pressures (DP's) 50 psf
All Doors and Glazing Installed
shall be Impact Rated
Flood Zone: FIRM - X
Finish Floor Elevation:
Min. 36'' A.CL.RW.
Mean Roof Height:
I,
L
a
r
r
y
M
.
O
l
i
v
e
r
,
P
.
E
.
,
L
i
c
e
n
s
e
N
o
.
1
2
6
7
8
Ce
r
t
i
f
y
t
h
a
t
t
h
e
s
t
r
u
c
t
u
r
a
l
p
o
r
t
i
o
n
s
o
f
t
h
i
s
se
t
o
f
c
o
n
s
t
r
u
c
t
i
o
n
d
o
c
u
m
e
n
t
s
h
a
v
e
b
e
e
n
re
v
i
e
w
e
d
u
n
d
e
r
m
y
r
e
s
p
o
n
s
i
b
l
e
c
h
a
r
g
e
,
de
s
i
n
a
t
e
d
b
y
d
e
s
i
g
n
,
t
o
c
o
m
p
l
y
w
i
t
h
t
h
e
en
g
i
n
e
e
r
i
n
g
r
e
q
u
i
r
e
m
e
n
t
s
o
f
t
h
e
In
t
e
r
n
a
t
i
o
n
a
l
R
e
s
i
d
e
n
t
i
a
l
B
u
i
l
d
i
n
g
C
o
d
e
,
20
1
8
L
a
t
e
s
t
E
d
i
t
i
o
n
@
1
3
0
/
1
6
0
-
m
p
h
3
se
c
g
u
s
t
w
i
n
d
l
o
a
d
r
a
t
i
n
g
.
La
r
r
y
M
.
O
l
i
v
e
r
E
n
t
e
r
p
r
i
s
e
s
I
n
c
.
72
2
8
O
a
k
b
r
i
a
r
D
r
i
v
e
S
o
u
t
h
Mo
b
i
l
e
,
A
L
.
3
6
6
1
9
A 1.8A 1.8A 1.8A 1.8
PE
R
M
I
T
J
U
R
I
S
D
I
C
T
I
O
N
:
CI
T
Y
O
F
F
A
I
R
H
O
P
E
B.
F
.
E
.
:
1
2
'
'
A
.
C
L
.
R
W
FL
O
O
D
Z
O
N
E
:
"
X
"
CO
N
T
R
A
C
T
O
R
:
S
T
E
V
E
J
O
N
E
S
C
O
N
T
R
A
C
T
O
R
PR
O
J
E
C
T
:
R
E
M
O
D
E
L
S
I
N
G
L
E
F
A
M
I
L
Y
R
E
S
.
CL
I
E
N
T
:
L
U
C
I
N
D
A
&
C
H
I
P
C
H
A
P
P
E
L
L
E
LO
C
A
T
I
O
N
:
F
A
I
R
H
O
P
E
,
A
L
.
PH
Y
S
I
C
A
L
A
D
D
R
E
S
S
:
2
1
0
G
A
Y
F
E
R
C
T
.
Base Slab Elev: 24''' A.F.G. (Varies)
FINAL REVIEW - 12/04/25
PRELIM. REVIEW -09/16/25
PRELIM. REVIEW - 11/04/25
PRELIM. REVIEW - 10/07/25
PRELIM. REVIEW -09/17/25
c
2
0
2
5
C
O
P
Y
R
I
G
H
T
B
Y
K
.
A
.
T
.
D
e
s
i
g
n
s
I
n
c
.
T
h
e
s
e
d
r
a
w
i
ng
s
a
r
e
N
O
T
T
O
B
E
re
p
r
o
d
u
c
e
d
o
r
c
o
p
i
e
d
i
n
a
n
y
f
o
r
m
w
h
a
t
s
o
e
v
e
r
w
i
t
h
o
u
t
t
h
e
w
r
i
t
t
e
n
pe
r
m
i
s
s
i
o
n
o
f
K
.
A
.
T
.
D
e
s
i
g
n
s
I
n
c
.
-
A
N
Y
D
U
P
L
I
C
A
T
I
O
N
I
S
P
R
O
H
I
B
I
T
E
D
A
N
D
PU
N
I
S
H
A
B
L
E
U
N
D
E
R
F
E
D
E
R
A
L
L
A
W
.
T
h
e
p
u
r
c
h
a
s
e
r
h
a
s
t
h
e
ri
g
h
t
t
o
O
N
E
US
E
f
o
r
p
e
r
m
i
t
t
i
n
g
p
u
r
p
o
s
e
s
,
a
n
y
f
u
t
u
r
e
u
s
e
o
f
t
h
e
pl
a
n
,
i
d
e
a
s
,
e
l
e
v
a
t
i
o
n
s
,
co
n
t
e
n
t
s
,
o
r
c
h
a
n
g
e
s
t
o
d
e
s
i
g
n
a
r
e
t
h
e
p
r
o
p
e
r
t
y
o
f
K
.
A
.
T
.
D
e
s
i
g
n
s
I
n
c
.
AN
D
M
U
S
T
B
E
A
U
T
H
O
R
I
Z
E
D
B
Y
K
.
A
.
T
.
D
e
s
i
g
n
s
I
n
c
.
A
N
Y
U
NA
T
H
O
R
I
Z
E
D
U
S
E
WI
L
L
B
E
P
U
N
I
S
H
A
B
L
E
U
N
D
E
R
F
E
D
E
R
A
L
C
O
P
Y
R
I
G
H
T
L
A
W
S
.
REAR / SOUTHERN ELEVATION PATIO GABLE
END WALL DETAIL - SCALE 1/2'' = 1'-0''
GA
B
L
E
E
N
D
C
U
T
T
H
R
U
V
I
E
W
-
ST
R
U
C
T
U
R
A
L
N
O
T
E
S
&
D
E
T
A
I
L
S
CT
A 1.8
Page 27 of 63
S
S
SS
S
S
S S
S
S
S S
S S
SS
S
S
-4
0
'
'
E
L
E
V
-4
'
'
F
.
F
.
EL
E
V
6'-10"
2'
-
5
"
3'-6"
4'-4"
4'
-
1
0
"
0'
'
E
L
E
V
-6
'
'
E
L
E
V
0'' F.F.
ELEV
-40'' ELEV
0'
'
F
.
F
.
EL
E
V
-4
0
'
'
E
L
E
V
-40'' ELEV
-4'' F.F.
ELEV
-4'' ELEV
0'' F.F.
ELEV
45
'
-
9
"
6'-9"10"6'-6"10"7'-7"
1'
-
0
"
7'
-
6
"
1'
-
0
"
7'
-
1
0
"
3'
-
9
"
1'-0"9'-0"1'-0"8'-11"1'-0"9'-0"1'-0"
4'
-
2
"
5'
-
5
"
82
'
-
1
"
16
'
-
0
"
10
'
-
9
"
12'-0"17'-0"
78'-3"
31'-1"18'-3"
17
'
-
4
"
82
'
-
1
"
4'
-
0
"
21
'
-
5
"
13
'
-
1
"
26
'
-
3
"
16
'
-
3
"
8'
-
0
"
2'
-
0
"
4'-7"
73'-8"
14'-5"22'-6"24'-3"12'-6"
1'-9"9'-0"1'-9"
26
'
-
6
"
12'-0"
20'-4"10'-3"17'-4"
22
'
-
1
0
"
28'-11"
1'
-
0
"
4'
-
5
"
30'-3"
1'
-
0
"
4'
-
6
"
15
'
-
1
1
"
22
'
-
6
"
19'-0"
4'-7"14'-5"
12
'
-
5
"
EXISTING SLAB AREA N.T.B.
DISTURBED
EX
I
S
T
I
N
G
2
x
8
'
'
F
L
O
O
R
S
Y
S
.
w
/
8
'
'
C
M
U
BL
O
C
K
S
U
P
P
O
R
T
S
N
.
T
.
B
.
D
I
S
T
U
R
B
E
D
EXISTING 2x8'' FLOOR SYS. w/ 8'' CMU
BLOCK SUPPORTS N.T.B. DISTURBED
EXISTING 2x8'' FLOOR SYS. w/ 16'' CMU PIER SUP. w/6X6 BEAM N.T.B. DISTURBED
BUILDER TO USE H2.5 TO ATTACH EA. EXISTING 2x8''
JOIST TO 6X6 EXISTING BEAM SUPPORTS TYP T.O.
NE
W
2
x
1
2
'
'
F
L
O
O
R
S
Y
S
.
w
/
8
'
'
C
M
U
w
/
16
'
'
C
M
U
@
B
A
S
E
C
O
U
R
C
E
S
U
P
P
O
R
T
EN
D
W
A
L
L
E
X
I
S
T
I
N
G
H
S
E
NE
W
F
L
O
O
R
A
R
E
A
@
E
X
T
W
A
L
L
GARAGE F.F.E. - STEP DN TO
GARAGE FLR. TO FIN. SLAB
BASED ON GRADE @ SITE
SL
O
P
E
T
O
E
X
T
.
NEW 4" 3000 PSI CONCRETE SLAB, OVER 6X6X10 WWM, w/ WIRE
MESH SUPPORTS MIN 3" A.F.G.OVER 6 MIL VAPOR BARRIER, OVER
CLEAN COMPACTED & TERMITE TREATED FILL TYPICAL T.O. - SEE
WALL SUPPORT DETAILS FOR FOOTER SIZE & LOCATIONS
NEW 4" 3000 PSI CONCRETE SLAB, OVER 6X6X10 WWM, w/ WIRE MESH
SUPPORTS MIN 3" A.F.G.OVER 6 MIL VAPOR BARRIER, OVER CLEAN
COMPACTED & TERMITE TREATED FILL TYPICAL T.O. - SEE WALL
SUPPORT DETAILS FOR FOOTER SIZE & LOCATIONS
NEW 4" 3000 PSI CONCRETE SLAB,
OVER 6X6X10 WWM, w/ WIRE MESH
SUPPORTS MIN 3" A.F.G.OVER 6
MIL VAPOR BARRIER, OVER CLEAN
COMPACTED & TERMITE TREATED
FILL TYPICAL T.O. - SEE WALL
SUPPORT DETAILS FOR FOOTER
SIZE & LOCATIONS
BU
I
L
D
E
R
T
O
P
O
U
R
B
R
I
C
K
L
E
D
G
E
w
/
F
O
O
T
I
N
G
S
BUILDER TO POUR BRICK LEDGE w/ FOOTINGS
BUILDER TO POUR BRICK LEDGE w/ FOOTINGS
BU
I
L
D
E
R
T
O
P
O
U
R
B
R
I
C
K
L
E
D
G
E
w
/
F
O
O
T
I
N
G
S
BUILDER TO POUR BRICK LEDGE w/ FOOTINGS
BU
I
L
D
E
R
T
O
P
O
U
R
B
R
I
C
K
L
E
D
G
E
w
/
F
O
O
T
I
N
G
S
PORCH ELEVATION -4" TO MAIN SLAB
8'' CMU AT EXTERIOR EDGE HGT.
BASED ON GRADE ELEV
BUILDER TO POUR BRICK
LEDGE w/ FOOTINGS
PA
51
8'' x 16'' CMU BLOCK STEM WALL FOUNDATION
HEIGHT VARIES BASED ON FINISHED GRADE
PLAN SCALE 1/4'' = 1'-0''
FOUNDATION TO BE CONSTRUCTED AS: 8'' CMU BLOCK STEM WALL "WHERE NOTED " w/ 4" 3000 PSF CONCRETE SLAB, OVER 6.6.10. WWM, w/ WIRE MESH SUPPORTS MIN 3" A.F.G. OVER 6 MIL
VAPOR BARRIER, OVER CLEAN COMPACTED 2500 PSF & TERMITE TREATED FILL. TYPICAL THROUGHOUT 12'' d x 24'' w FOOTINGS TO BE AS NOTED IN SPECIFIC DETAILS PER WALL SECTION
SUPPORTED w/3 #5 REBAR INSERTS ON RISERS TYP. - BUILDER TO TURN W.W.M INTO ALL FOOTINGS. BUILDER TO INSTALL 1 #5 REBAR EVERY 32'' IN CMU CELLS TURNED INTO SLAB MIN 25''
ALL CELLS POURED SOLID. INTERIOR SUPPORT FOOTINGS SHALL REFLECT (DETAIL PG A1.9) GRADE BEAMS WHERE NOTED. MAIN HSE FOOTINGS SHALL BE A MIN. 12'' d x 24'' w/4'' FINISHED
SLAB ELEV. BASED ON FINISHED GRADE @ SITE. INSTALL 5/8'' x 10'' "J" TYPE ANCHOR BOLTS EVERY 32'' O.C. THRU-OUT SLAB EXT. OFFSET DOOR LOCATIONS. SLOPE ALL PORCH SLABS TO
EXT. FOR RUN OFF. BASEMENT STORAGE RM TO START WITH A 8'' x 12'' x16'' BASE COURSE OF CMU WHERE WALL SECTIONS HEIGHT EXCEED 6 FT. BASED ON GRADE ELEV.
# of STEPS TO GRADE BY BUILDER BASEG ON SLOPE GRADE
#
o
f
S
T
E
P
S
T
O
G
R
A
D
E
B
Y
BU
I
L
D
E
R
B
A
S
E
G
O
N
SL
O
P
E
G
R
A
D
E
BU
I
L
D
E
R
T
O
P
O
U
R
B
R
I
C
K
L
E
D
G
E
w
/
F
O
O
T
I
N
G
S
0''
ELEV
0''
ELEV
0''
ELEV
0''
ELEV
0''
ELEV
-97
F.F. ELEV
BU
I
L
D
E
R
T
O
P
O
U
R
4
'
'
C
O
N
C
S
L
A
B
@
BA
S
E
F
O
R
S
T
O
R
A
G
E
R
M
F
.
F
.
S
L
A
B
4'' RECESS SHOWER PAN
2x8'' JOIST
UNDER SHOWER
PAN @ 12'' O.C.
2 PLY 2x12
2 PLY 2x12
2'
-
5
'
'
4''
ELEV
0
ELEV
EXISTING 16'' CONC PIERS NEED TO BE FILLED SOLID w/MSTCA STRAP TO 6X6 BEAM
NEW 8'' CMU BLK STEM WALL w/ 1 #4 @ 32'' O.C. POURED SOLID
THIS WALL SETS ADJACENT TO EXISTING PIERS
NEW 4" 3000 PSI CONCRETE SLAB,
OVER 6X6X10 WWM, w/ WIRE MESH
SUPPORTS MIN 3" A.F.G.OVER 6
MIL VAPOR BARRIER, OVER CLEAN
COMPACTED & TERMITE TREATED
FILL TYPICAL T.O.PA
51
ABU
12z
ABU
12z
ABU
12z
ABU
12z
ABU
12z
C/D
A1.9
C/D
A1.9
C/D
A1.9
C
A1.9
C/D
A1.9
C
A1.9
C
A1.9
C/D
A1.9
C/D
A1.9
C/D
A1.9
C
A1.9
C/D
A1.9
C
A1.9C
A1.9
C
A1.9
C
A1.9
C/D
A1.9
B
A1.9
B
A1.9
B
A1.9
B
A1.9
B
A1.9
A/E
A1.9
A/E
A1.9
A
A1.9
A/E
A1.9
A/E
A1.9
A/E
A1.9
A/E
A1.9
A/E
A1.9
A/E
A1.9
A
A1.9
A
A1.9
A
A1.9
EXISTING 8'' CMU BLK STEM
WALL @ REAR OF GARAGE
EXISTING 8'' CMU BLK STEM
WALL @ GARAGE PERIMETER.
EXISTING 8'' CMU BLK STEM
WALL @ GARAGE PERIMETER.
EX
I
S
T
I
N
G
8
'
'
C
M
U
B
L
K
S
U
P
W
A
L
L
C
A1.9
BUILDER TO VERIFY ALL
EXISTING DIMENSIONS AND
ADJUST ACCORDINGLY
BUILDER SEE NOTE: #11 & 12 UNDER
ASI-2018 CONCRETE NOTES (PG A1.9)
E
A1.9
E
A1.9 E
A1.9
GENERAL CONCRETE CONSTRUCTION NOTES:
=========================================
1. FOOTINGS ARE TO BEAR ON UNDISTURBED LEVEL SOIL DEVOID OF ANY ORGANIC MATERIAL TERMITE TREATED
AND STEPPED AS REQUIRED TO MAINTAIN THE REQUIRED DEPTH BELOW THE FINAL GRADE BASED ON
ENGINEERING OF SOIL BASE / TOPOGRAPHICAL REPORT PROVIDED BY OWNERS IF NECESSARY.
2. SOIL BEARING PRESSURE ASSUMED TO BE 1500 PSF.
3. MAXIMUM SLOPE OF CUTS AND FILLS TO BE TWO (2) HORIZONTAL AND ONE(1) VERTICAL FOR BUILDING,
STRUCTURES,FOUNDATIONS AND RETAINING WALLS.
4. ANY FILL UNDER GRADE SUPPORTED SLABS TO BE MIN.4" GRANULAR MATERIAL COMPACTED TO 95%.
5. CONCRETE: MIX & 28 DAY STRENGTH OF CONCRETE. -BASEMENT WALLS & FOUNDATIONS NOT EXPOSED TO
WEATHER: 3000 PSI INTERIOR SLABS ON GRADE: 3000 PSI , FOUNDATIONS EXPOSED TO WEATHER: 3000 PSI -
PORCHES,STEPS,& CARPORT SLABS EXPOSED TO WEATHER:3000 PSI (AS PER 2018 IRC APPENDEX - TABLE
A-19-A) MORTAR & GROUT TO BE MIXED PER MFR. REQUIREMENTS.
6. GARAGE FLOORS TO SLOPE 1/8" /P- FT. MIN. TOWARDS OPENING AS REQUIRED FOR DRAINAGE. CONCRETE
SLABS TO HAVE CONTROL JOINTS @ 12' FOR 4'' CONCRETE SLABS @ INTERVALS EA. WAY.
7. REINFORCING STEEL TO BE A-615 GRADE 60. WELDED OPTIONAL WIRE MESH TO BE A-185.
8. ALL WOOD IN CONTACT WITH CONCRETE TO BE PRESSURED TREATED OR PROTECTED WITH 55# ROLLED
ROOFING.
10. BEAM POCKETS IN CONCRETE TO HAVE 1/2" IN. AIRSPACE AT SIDES AND ENDS WITH A MIN. BEARING OF 3" IN.
11. WATER-PROOF CMU STEM WALLS BEFORE BACK FILLING. PROVIDING A 4" DIA. PERFORATED DRAIN PIPE &
GRAVEL BED BELOW THE TOP OF THE FOOTING FOR WATER RUN OFF/ DRAINING AWAY FROM FOOTINGS
ACI 2018 FOUNDATION NOTES: TO COMPLY w/ IRC 2018 - SEC.R401, R403, R403 INCLUDES TABLES & SUB SEC.
==============================================================================================
1. CONCRETE COMPRESSIVE STRENGTH AT 28 DAYS: 3000 PSI --- NORMAL WEIGHT --- UNLESS NOTED WATER /
CEMENT RATIO 0.45 OR LESS. CONCRETING OPERATIONS SHALL COMPLY WITH ACI STANDARDS.
2. REINFORCING BARS: ASTM A615 GRADE 60.
3. WELDED WIRE FABRIC (WWF): ASTM A185. 6 x 6 W2.9/2.9
4. REINFORCING BAR PLACING ACCESSORIES IN ACCORDANCE WITH ACI MANUAL OF STANDARD PRACTICE.
5. DETAIL REINFORCEMENT IN ACCORDANCE WITH ACI 315. REINFORCEMENT SHALL NOT BE WELDED UNLESS
NOTED OR APPROVED BY THE ENGINEER.
6. LAP ALL REINFORCEMENT SPLICES A MINIMUM OF 30 BAR DIAMETERS BUT NOT LESS THAN 1'-0", UNLESS
NOTED.
7. CONCRETE COVERAGE OF REINFORCEMENT: GRADE BEAMS --- 3" BOTTOM AND SIDES, 2" TOP.
8. EARTH SUPPORTED SLABS: (INCLUDING EXTERIOR WALK AND DRIVE SLABS) 4" THICK. REINFORCED WITH 6
x 6 W2.9/2.9 WWF AT MID-DEPTH OF SLAB, UNLESS NOTED.
9. ALL UNDER SLAB AREAS TO BE TREATED FOR TERMITES BY A LICENSED APPLICATOR. OWNER TO RECEIVE
RENEWABLE BOND.
10. ALL FOOTINGS TO BEAR ON UNDISTURBED SOIL OR COMPACTED FILL OF 95% DENSITY.
11. IF CONCRETE BASEMENT WALLS ARE LESS THEN 8 FEET HEIGHT, PLACE ONE #4 REBAR MIN. WITHIN 12'' OF
THE TOP OF THE WALLSTORY AND ONE #4 REBAR MIN. NEAR THE MID-HEIGHT OF THE WALL STORY.PER IRC -
SEC. R404.1.2(1)
12. IF THE CONCRETE BASEMENT WALLS ARE GREATER THAN 8 FT IN HEIGHT, PLACE ONE #4 REBAR MIN.
WITHIN 12'' OF THE TOP OF THE WALL STORY AND ONE #4 REBAR MIN.NEAR THE THIRD POINTS OF THE WALL
STORY. PER IRC - SEC. R404.1.2(1)
2'-0"
1'
-
0
"
5/8'' DIA. x 12'' A.B. @ 32''
O.C. TYP w/ 3'' sq. washer
MACHINE COMPACTED
& TERMITE TREATED
FILL TO 2500 PSF
3 @ #5 REBAR
CONT.
3000 # psi
CONCRETE FTR
BRICK VENEER @ BASE -
EXT. WALL SECTIONS .
4" 3000 psi
concrete slab
2x6 pt plate
8'' x8'' x16'' CMU BLK. EXTERIOR STEM WALL
2x6 EXT. WALL
STUDS @ 16''.O.C.
A
A1.9
4'' GRAVEL FILL
USE OF 1 FHA HEADER
BLOCK w/ STANDARD
8" x8''x16" CMU (MAINTAIN
MIN. 60'' HGT. CMU A.F.G.)
12"d x 24 w" CONC.
FOOTER w/3 @ #5
REBAR MIN. 6'' SEP.
CONT. THRU-OUT
FOOTER - REBAR
SHALL BE INSTALLED
ON RISERS MIN 3"
ABOVE GRADE.
8" X16" FILLED CMU w/ 1 #5
VERTICAL REBAR @ EVERY
32" O.C. TURNED INTO SLAB
MIN. 25'' w/ ALL CORES TO
BE POURED SOLID w/SLAB
Course Gravel
4" perforated drainpipe
Filter fabric
Rigid Insulation
Low-permeability soil
Slope away from wall
at 6" to 10'
N.T.S.
SIMPSON STRONG TIE
ABU1212Z POST BASE (
FOR USE w/12'' PT POST
w/ BOLT TO SLAB CON.
PER MANUF. INSTR.
Simpson Strong-Tie
2"MINIMUM
SIDECOVER
ABU S.S. POST BASE
ABU
1212z
BRICK VENEER TIES TO BE
INSTALLED TO SUPPORT NOT
MORE THAN 2 SQ FT OF WALL
AREA. ADDITIONAL TIES SHALL BE
PROVIDED WITHIN 12'' OF WALL
OPENINGS AND CORNERS.
BUILDER TO ALLOW FOR 1/2'' AIR
SPACE BETWEEN SECTION.- PER
SECTION (IRC 703.7.4.1)
Simpson Strong-Tie BT
PA51 N.T.S.
Simpson
PA51 - APPLY @
ALL CORNERS &
OPENINGS OVER 6
FT HOLD DOWN 1 @
each side of opening
PA
51
2'-0"
2'
-
0
"
ADD
CORNER
BAR
overlap min.
25" @ corners
N.T.S.
ADD CORNER
BAR
3 #5 CONT.
(18"d x 24"w ) CONTINUOUS
FTG @ CORNERS
C
A1.9
Simpson Strong-Tie -
HD5A or PA51 opt.
Install 1 within 6'' of ea
Ext. Corner in both
directions
Install 1 @ ea Side of
Stud pack @ Window or
Door openings over 60''
D
A1.9
NTS
TYP. EXT. PERIMETER WALL 8"x16" CMU BLK SUPPORT WALL
1-#4
REBAR
1 1/2" MIN.
COVER
BOND BEAM
U ChannelSTANDARD HOOK
3" MIN. COVER 3 @ #5 REBAR - REINFORCING
STANDARD HOOK
25" LAP MIN.CLEANOUT REC'D FOR
GROUT LIFT > 5'
2x8'' PT
TOP PLT.
2x8'' PT
TOP PLT.
5/8'' x 10'' AB
@ 36'' O.C.E
A1.9
VERTICAL REINFORCEMENT (1 # 5 REBAR) @ 32'' - ALL CELLs POURED SOLID
FOOTING
12'' X 24''
ADD 1-#4 REBAR @
MID- HEIGHT OF
THE WALL STORY
OVER 8 FT HGT
1'
-
0
"
2'-0"1'
-
0
"
2'-0"
EXISTING WL
5/8'' APA RATED EXT.
SHEATHING
5/8'' DIA A.B. 10'' @ 32'' OC
SLAB ON GRADE CONST.
EXISTING PLT.
8" X16" FILLED CMU w/ 1 #5
VERTICAL REBAR @ 32'' TURNED
INTO SLAB MIN. 25''
# OF BLOCKS MAY VARY BASED
ON GRADE ELEVATION AT SITE
SECTION
2x8'' JOIST
3 #5 REBAR
CONTINUOUS
3000 # psi 12'' x 24''
CONCRETE FOOTER
CLEAN & TERMITE TREATED FILL
DIRT W/ VAPOR BARRIER
N. T. S.
R-13/19 INSULATION
6 MIL VAPOR BARRIER
DETAIL NOT SPECIFIC
TO SITE CONDITIONS
FOUNDATION DETAIL @ FRONT HSE WALL / EXT PORCH PERIMETER SUP.
C
A1.9
- 4'' STEP DWN
0'' F.F.E.
SLOPE
EXTISTING WALL
FRONT PORCH
12'' TIMBER POST B.O.
ABU12z
POST BASE
FRONT
PORCH
EXT.
w/ 3''
BRICK
VENEER
HARDIE B&B ON FRONT
PORCH FACE WL.
GOLD FORTIFICATION FOUNDATION ANCHOR REQ:
============================================
Anchor floor system and exterior walls to foundation using 5/8-in-diameter anchor bolts
with 3-in. x 3-in. x ¼-in-thick plate washers using the appropriate spacing described below:
=============================================
For slab-on-grade, 24-in. spacing of anchor bolts and within 12 in. of the end of plate.
==============================================
For raised floor foundation including stem-wall foundations:
1. 72-in. spacing for a one-story structure along exterior walls in long direction of building
2. 56-in. spacing for a two-story structure along exterior walls in long direction of building
3. 32-in. spacing for a one-story structure along exterior walls (and interior shear walls if
present) in short direction (across width) of building
b. 24-in. spacing for a two-story structure along exterior walls (and interior shear walls if
present) in short direction (across width) of building
2'-0"
1'
-
0
"
5/8'' DIA. x 12'' A.B. @ 32''
O.C. TYP w/ 3'' sq. washer
MACHINE COMPACTED
& TERMITE TREATED
FILL TO 2500 PSF
3 @ #5 REBAR
CONT.
3000 # psi
CONCRETE FTR
4" 3000 psi
concrete slab
2x6 pt plate
8'' x8'' x16'' CMU BLK. EXTERIOR STEM WALL
2x6 EXT. WALL
STUDS @ 16''.O.C.
B
A1.9
4'' GRAVEL FILL
USE OF 1 FHA HEADER
BLOCK w/ STANDARD
8" x8''x16" CMU ADJUST
HGT BASED ON FIN GRADE
12"d x 24'' w CONC.
FOOTER w/ 3@ #5 REBAR
MIN. 6'' SEP. CONT.
THRU-OUT FOOTER -
REBAR SHALL BE
INSTALLED ON RISERS MIN
3" ABOVE GRADE.
8" X16" FILLED CMU w/ 1 #5
VERTICAL REBAR @ EVERY
32" O.C. TURNED INTO SLAB
MIN. 25'' w/ ALL CORES TO
BE POURED SOLID w/SLAB
N.T.S.
MACHINE COMPACTED
& TERMITE TREATED
FILL TO 2500 PSF
4" 3000 psi
concrete slab
PRINT DATES
FINAL PRINT - 12/09/25
DESIGN DRAWN BY
Kirk A. ThomasKirk A. ThomasKirk A. ThomasKirk A. Thomas
To
t
h
e
b
e
s
t
o
f
m
y
k
n
o
w
l
e
d
g
e
t
h
e
s
e
p
l
a
n
s
a
r
e
d
r
a
w
n
t
o
c
o
m
p
l
y
w
i
t
h
t
h
e
c
o
d
e
r
e
q
u
i
r
e
m
e
n
t
s
f
o
r
th
e
i
r
i
n
t
e
n
d
e
d
u
s
e
b
y
o
w
n
e
r
'
s
a
n
d
/
o
r
b
u
i
l
d
e
r
'
s
s
p
e
c
i
f
i
c
a
t
i
o
n
s
,
a
n
y
c
h
a
n
g
e
s
m
a
d
e
o
n
o
r
t
o
t
h
e
m
af
t
e
r
p
r
i
n
t
s
a
r
e
s
e
a
l
e
d
w
i
l
l
b
e
d
o
n
e
a
t
t
h
e
o
w
n
e
r
'
s
a
n
d
/
o
r
b
u
i
l
d
e
r
'
s
e
x
p
e
n
c
e
a
n
d
r
e
s
p
o
n
s
i
b
i
l
i
t
y
.
Th
e
c
o
n
t
r
a
c
t
o
r
s
h
a
l
l
v
e
r
i
f
y
a
l
l
d
i
m
e
n
s
i
o
n
s
a
n
d
e
n
c
l
o
s
e
d
d
e
t
a
i
l
d
r
a
w
i
n
g
s
.
R
e
f
e
r
I
n
s
t
a
l
l
a
t
i
o
n
o
f
a
l
l
ma
t
e
r
i
a
l
s
t
o
m
a
n
u
f
a
c
t
u
r
e
s
a
n
d
c
o
d
e
r
e
q
u
i
r
m
e
n
t
s
f
o
r
e
a
c
h
i
t
e
m
s
a
t
t
a
c
h
m
e
n
t
t
o
t
h
e
s
t
r
u
c
t
u
r
e
re
q
u
a
r
d
l
e
s
s
o
f
d
e
t
a
i
l
s
h
o
w
n
.
D
e
t
a
i
l
s
a
r
e
n
o
t
s
p
e
c
i
f
i
c
t
o
s
t
r
u
c
t
u
r
e
d
r
a
w
n
,
d
e
t
a
i
l
s
a
r
e
d
r
a
w
n
a
s
pe
r
s
p
e
c
t
i
v
e
c
u
t
a
w
a
y
v
i
e
w
s
a
n
d
i
n
n
o
w
a
y
s
h
o
w
m
a
t
e
r
i
a
l
i
t
e
m
s
a
s
f
i
n
i
s
h
e
d
i
n
s
t
a
l
l
e
d
re
p
r
e
s
e
n
t
a
t
i
o
n
.
k
.
a
.
t
.
D
e
s
i
g
n
s
I
n
c
.
i
s
n
o
t
l
i
a
b
l
e
f
o
r
e
r
r
o
r
s
b
a
s
e
d
u
p
o
n
p
e
r
s
o
n
a
l
i
n
t
e
r
p
r
e
t
a
t
i
o
n
of
a
n
y
d
e
t
a
i
l
,
t
e
x
t
i
t
e
m
,
o
r
s
y
m
b
o
l
u
s
e
d
i
n
t
h
e
c
r
e
a
t
i
o
n
o
f
t
h
e
s
e
d
o
c
u
m
e
n
t
s
.
W
h
i
l
e
e
v
e
r
y
e
f
f
o
r
t
ha
s
b
e
e
n
m
a
d
e
i
n
t
h
e
p
r
e
p
a
r
a
t
i
o
n
o
f
t
h
i
s
p
l
a
n
t
o
a
v
o
i
d
m
i
s
t
a
k
e
s
,
t
h
e
m
a
k
e
r
c
a
n
n
o
t
g
u
a
r
a
n
t
e
e
ag
a
i
n
s
t
h
u
m
a
n
e
r
r
o
r
.
T
h
e
L
i
c
.
C
o
n
t
r
a
c
t
o
r
/
O
w
n
e
r
s
o
f
t
h
e
p
r
o
j
e
c
t
m
u
s
t
c
h
e
c
k
a
l
l
d
i
m
e
n
s
i
o
n
s
a
n
d
de
t
a
i
l
s
p
r
i
o
r
t
o
c
o
n
s
t
r
u
c
t
i
o
n
a
n
d
b
e
s
o
l
e
l
y
r
e
s
p
o
n
s
i
b
l
e
u
p
o
n
i
s
s
u
e
d
p
e
r
m
i
t
.
A
l
l
i
n
f
o
r
m
a
t
i
o
n
co
n
t
a
i
n
e
d
w
i
t
h
i
n
t
h
e
s
e
p
l
a
n
s
i
s
s
u
b
j
e
c
t
t
o
c
h
a
n
g
e
b
a
s
e
o
n
c
o
d
e
r
e
q
u
i
r
e
m
e
n
t
s
a
n
d
p
e
r
m
i
t
t
i
n
g
ju
r
i
s
d
i
c
t
i
o
n
I
n
t
e
r
p
r
e
t
a
t
i
o
n
.
Page #Page #Page #Page #
PL
A
N
S
C
A
L
E
:
BA
S
E
@
1
/
4
"
=
1
'
-
0
'
'
U.
O
.
N
.
S
C
A
L
E
M
A
Y
V
A
R
Y
P
E
R
P
L
A
N
OR
P
E
R
D
E
T
A
I
L
(
N
O
T
S
P
E
C
I
F
I
C
)
Building Code: IRC2018
Design Wind Speed: 130 mph
ASD - ASCE 7-10
Design Wind Speed: 160 MPH
Ultimate - ASCE 7-16
Req. Glazing & Door Design
Pressures (DP's) 50 psf
All Doors and Glazing Installed
shall be Impact Rated
Flood Zone: FIRM - X
Finish Floor Elevation:
Min. 36'' A.CL.RW.
Mean Roof Height:
I,
L
a
r
r
y
M
.
O
l
i
v
e
r
,
P
.
E
.
,
L
i
c
e
n
s
e
N
o
.
1
2
6
7
8
Ce
r
t
i
f
y
t
h
a
t
t
h
e
s
t
r
u
c
t
u
r
a
l
p
o
r
t
i
o
n
s
o
f
t
h
i
s
se
t
o
f
c
o
n
s
t
r
u
c
t
i
o
n
d
o
c
u
m
e
n
t
s
h
a
v
e
b
e
e
n
re
v
i
e
w
e
d
u
n
d
e
r
m
y
r
e
s
p
o
n
s
i
b
l
e
c
h
a
r
g
e
,
de
s
i
n
a
t
e
d
b
y
d
e
s
i
g
n
,
t
o
c
o
m
p
l
y
w
i
t
h
t
h
e
en
g
i
n
e
e
r
i
n
g
r
e
q
u
i
r
e
m
e
n
t
s
o
f
t
h
e
In
t
e
r
n
a
t
i
o
n
a
l
R
e
s
i
d
e
n
t
i
a
l
B
u
i
l
d
i
n
g
C
o
d
e
,
20
1
8
L
a
t
e
s
t
E
d
i
t
i
o
n
@
1
3
0
/
1
6
0
-
m
p
h
3
se
c
g
u
s
t
w
i
n
d
l
o
a
d
r
a
t
i
n
g
.
La
r
r
y
M
.
O
l
i
v
e
r
E
n
t
e
r
p
r
i
s
e
s
I
n
c
.
72
2
8
O
a
k
b
r
i
a
r
D
r
i
v
e
S
o
u
t
h
Mo
b
i
l
e
,
A
L
.
3
6
6
1
9
PE
R
M
I
T
J
U
R
I
S
D
I
C
T
I
O
N
:
CI
T
Y
O
F
F
A
I
R
H
O
P
E
B.
F
.
E
.
:
1
2
'
'
A
.
C
L
.
R
W
FL
O
O
D
Z
O
N
E
:
"
X
"
CO
N
T
R
A
C
T
O
R
:
S
T
E
V
E
J
O
N
E
S
C
O
N
T
R
A
C
T
O
R
PR
OJ
E
C
T
:
R
E
M
O
D
E
L
S
I
N
G
L
E
F
A
M
I
L
Y
R
E
S
.
CL
I
E
N
T
:
L
U
C
I
N
D
A
&
C
H
I
P
C
H
A
P
P
E
L
L
E
LO
C
A
T
I
O
N
:
F
A
I
R
H
O
P
E
,
A
L
.
PH
Y
S
I
C
A
L
A
D
D
R
E
S
S
:
2
1
0
G
A
Y
F
E
R
C
T
.
Base Slab Elev: 24''' A.F.G. (Varies)
FINAL REVIEW - 12/04/25
PRELIM. REVIEW -09/16/25
PRELIM. REVIEW - 11/04/25
PRELIM. REVIEW - 10/07/25
PRELIM. REVIEW -09/17/25
c
2
0
2
5
C
O
P
Y
R
I
G
H
T
B
Y
K
.
A
.
T
.
D
e
s
i
g
n
s
I
n
c
.
T
h
e
s
e
d
r
a
w
i
n
g
s
a
r
e
N
O
T
T
O
B
E
re
p
r
o
d
u
c
e
d
o
r
c
o
p
i
e
d
i
n
a
n
y
f
o
r
m
w
h
a
t
s
o
e
v
e
r
w
i
t
h
o
u
t
t
h
e
w
r
i
t
t
e
n
pe
r
m
i
s
s
i
o
n
o
f
K
.
A
.
T
.
D
e
s
i
g
n
s
I
n
c
.
-
A
N
Y
D
U
P
L
I
C
A
T
I
O
N
I
S
P
R
O
H
I
B
I
T
E
D
A
N
D
PU
N
I
S
H
A
B
L
E
U
N
D
E
R
F
E
D
E
R
A
L
L
A
W
.
T
h
e
p
u
r
c
h
a
s
e
r
h
a
s
t
h
e
r
i
g
h
t
t
o
O
N
E
US
E
f
o
r
p
e
r
m
i
t
t
i
n
g
p
u
r
p
o
s
e
s
,
a
n
y
f
u
t
u
r
e
u
s
e
o
f
t
h
e
p
l
a
n
,
i
d
e
a
s
,
e
l
e
v
a
t
i
o
n
s
,
co
n
t
e
n
t
s
,
o
r
c
h
a
n
g
e
s
t
o
d
e
s
i
g
n
a
r
e
t
h
e
p
r
o
p
e
r
t
y
o
f
K
.
A
.
T
.
D
e
s
i
g
n
s
I
n
c
.
AN
D
M
U
S
T
B
E
A
U
T
H
O
R
I
Z
E
D
B
Y
K
.
A
.
T
.
D
e
s
i
g
n
s
I
n
c
.
A
N
Y
U
N
A
T
H
O
R
I
Z
E
D
U
S
E
WI
L
L
B
E
P
U
N
I
S
H
A
B
L
E
U
N
D
E
R
F
E
D
E
R
A
L
C
O
P
Y
R
I
G
H
T
L
A
W
S
.
NE
W
F
O
U
N
D
A
T
I
O
N
P
L
A
N
w/
N
O
T
E
S
&
D
E
T
A
I
L
S
A 1.9A 1.9A 1.9A 1.9
FOUNDATION OVERVIEW -
SCALE 1/8'' = 1'-0''
Page 28 of 63
FLOOR TRUSS /TJ I - JOIST NOTES:
1. ALL TJI FLOOR JOIST SHOWN IN PLANS ARE FOR DIAGRAMATIC AND PERSPECTIVE
USE ONLY AS 3-D AND ARCHITECTURAL VIEW REPRESENTATION.
2. ALL TJI FLOOR JOIST SHALL BE ENGINEERED BY MANUFACTURER BASED ON JOIST
HEIGHT, SPAN, SPACING, FLOOR LOADS, WEIGHT DISTRIBUTION AND SUBMITTALS
SIGNED AND SEALED BY MANUFACTURER'S ENGINEER.
3. CONTRACTOR AND BUILDING PERMIT OFFICIAL SHALL REFER TO MANUFACTURER'S
ENGINEERING DOCUMENTS AND NOT TO PLANS FOR INSTALLATION, BRACING AND
HOLD DOWN REQUIREMENTS. MANUFACTURER HAS DESIGN AND FABRICATION
JURISDICTIONAL ENGINEERING RIGHTS AND LIABILITY OVER INFORMATION SHOWN IN
PLANS AND OVER PROJECT ENGINEER.
4. ALL JOIST CONNECTIONS TO SUPPORTS SHALL BE SPECIFIED BY THE FLOOR SYSTEM
MANUFACTURER'S ENGINEER.
5. SUB-FLOORING SHALL BE SCREWED AND GLUED TO THE FLOOR JOIST PER IRC-2018
REQUIREMENTS.
6. FLOOR SYSTEM NAILING AT END BEARING - 2 EACH 10D (3'' LONG) OR 12D (3 1/4'' LONG)
BOX NAILS (ONE ON EACH SIDE) 1 1/2'' MINIMUM FROM END.
7. FLOOR SYSTEM NAILING AT INTERMEDIATE BEARING - 2 EACH 10D (3'' LONG) OR 12D
(3 1/4'' LONG) BOX NAILS (TWO ON EACH SIDE) 1 1/2'' MINIMUM FROM END.
8. FLOOR SYSTEM MINIMUM BEARING LENGTH - END SUPPORT - 1 3/4'', INTERMEDIATE
SUPPORT - 3 1/2'' BEARING.
9. FLOOR SYSTEM BRACING MUST COMPLY TO CODE REQUIREMENTS AND SHALL BE
CARRIED TO THE FOUNDATION.
10. IF SIDES OF HANGER DO NOT LATERALLY SUPPORT THE FLOOR SYSTEM TOP FLANGE
OR WHEN USING SIMPSON JOIST HANGERTYPE THA-218-2, APPLY A 2X TYPE STIFFENER
AS REQUIRED BY DOCUMENTS.
11. FLOOR SYTEM HANGER NAILING: FOR THA-218-2 (10D X 1 1/2'' LONG) FOR MIT416
(10D X 1 1/2'' LONG) NAILS. PLACE NAILS IN ALL HOLES. FOR FLOOR JOIST HEADERS
USE TOP FLANGE HANGERS WITH (10D X 3'' LONG COMMON NAILS).
SIMPSON STRONG TIE H2.5
HURRICANE TIES (2) AT
EACH END INSIDE WALL
PLATE TO FLOOR SYSTEM TO
WALL CONNECTION
N.T.S.
1
A1.10
TJI OR OPEN WEB
ENG. FLOOR TRUSS
OPT. LSTA- 36
STRAP STUD TO
TRUSS TO STUD
Exterior Wall Continuous Connection2
A1.10 N.T.S.
15/32'' or 7/16'' or 19/32''
Ext. Shearwall Sheathing
SIMPSON
STRONG TIE Coil
Strap CS52
SIMPSON
STRONG TIE
LSTA-36 for
Floor Truss Use
ENG FLOOR
TRUSS
TJI- JOIST
FLOOR
TRUSSES @
16'' O.C.
16''
APPLY BLOCKING
OR STIFFINERS3 1/2'' TOP CHORD
3/4'' PLYWD SUB
FLOORING
2X4'' or 6'' BRG. PLT.
FLOOR JOIST
INSULATION
2X6 CONNECTION BAND
TRUSS TO TRUSS.
5/8'' EXT.
PLYWD
SHEERWALL
SHEATHNG
5/8'' DRYWALL CEILING
3
A1.10
WOOD FLOOR TRUSS SYSTEM
2'' = 1'-0''
2 -5/16 " X 16" TJI FLOOR JOIST @ 12''/16" O.C.
or 3 1/2''x 16'' ENG FLOOR TRUSS @ 12'' /16'' O.C.
1" X 16" RIM JOIST
5/8" EXTERIOR
SHEATHING5/8" DRYWALL CEILING
RIM JOIST INSULATION
3/4" T & G PLYWOOD
FLOORING
PRE ENGINEERED TRUSS FLOOR SYSTEM
- 16" O.C. w/ 1/2' TYPE GYP. CEILING
5
A1.10
THIS IS A PERSPECTIVE OVERVIEW OF THE PRE- ENGINEERED TYPE FLOOR SYSTEMS APPROVED FOR USE BY THE ENGINEER OF RECORD. SHOWN
FOR THE USE OF 3-D ARCHITECTURAL PURPOSES AND NOT THAT OF THE ACTUAL MANUFACTURER'S FINAL DESIGNED FLOOR SYSTEM PER THE
ENGINEERED DOCUMENTS SUBMITTED TO THE BUILDING OFFICIALS - PLEASE REFER ALL INSTALLED FLOOR SYSTEM MEMBERS TO THE
INFORMATION PROVIDED BY TRUSS MANUFACTURER'S DOCUMENTATION AND NOT THAT OF THESE PLANS AS FINAL INSTALLED INFORMATION.
BEAM
SIMPSON STRONG TIE THA - 218-2
ADJUSTABLE TRUSS/I-JOIST HANGER
FASTENED WITH :
(6) 0.162 X 3 1/2'' NAILS,
AND (6) 0.148 X 3'' NAILS.
TOP FLANGE
MINIMUM OF 2 1/2" OF TOP
FLANGE MATERIAL FOR MIN.
NAILING CONFIGURATION
THA -218-2
WALL
SUPPORT
USE WITH 2 OR
3 PLY BEAMS
4
A1.10 N.T.S.
WOOD BEAM FLOOR
TRUSS/I-JOIST HANGERS
D/W D/W
REF.
UP
DN
FTR-8
FTR-0
FTR-0
FTR-0
FTR-8 FTR-2
FTR-1
FTR-1
FTR-1
FTR-1
FTR-1
FTR-9
FTR-9
FTR-9
FTR-9
FTR-9
FTR-1FTR-3
FTR-3
FTR-3
FTR-3
FTR-3
FTR-3
FTR-3
FTR-3
FTR-7
FTR-7
FTR-7
FTR-7
FTR-7
FTR-3
FTR-3
FTR-3
FTR-3
FTR-3
FTR-3
FTR-3
FTR-3
FTR-3
FTR-3
FTR-3
FTR-3
FTR-3
FTR-3
FT
R
-
4
FTR-5
FTR-5
FTR-5
FTR-5
FTR-5
FTR-5
FTR-5FTR-5
FT
R
-
6
FT
R
-
6
FT
R
-
6
FT
R
-
6
FT
R
-
6
FT
R
-
6
FT
R
-
6
FT
R
-
6
FT
R
-
6
FT
R
-
6
ZERO ENTRY
@ SHOWER
10' 5''
T.O.B.
10
'
5
'
'
T.
O
.
B
.
10' 5''
T.O.B.
2x6
WALL
2x6
WALL
2x6 W
L
10' -1 1
/8''
2x6
WALL
2x6
WALL
2x4
EXISTING WL
2x
4
@
4
0
'
'
H
G
T
EX
I
S
T
I
N
G
W
L
2x4
EXISTING WL
2x6
WALL
2x6 W
L
10' -1 1
/8''
2x6 WL
10' -1 1/8''
10' 5''
T.O.B.
2x6 W
L
10' -1 1
/8''
2x4 W
L
10' -1 1
/8''
2x
6
W
L
10
'
-
1
1
/
8
'
'
2x6 W
L
12' -1 1
/8''
2x4 W
L
12' -1 1
/8''
2x4 W
L
12' -1 1
/8''
2x
4
W
L
10
'
-
1
1
/
8
'
'
3 PLY PORCH BEAM
10' -5
3
P
L
Y
1
.
7
8
'
'
x
1
6
'
'
L
V
L
B
E
A
M
4
P
L
Y
1
.
7
8
'
'
x
1
6
'
'
L
V
L
B
E
A
M
4 PLY 1.78'' x 16'' LVL BEAM - UNDER WALL SECTION
DBL FLR TR @ WALL SEC
DBL FLR TR @ WALL SEC
SHOWN AS 3 1/2'' x 16'' DEEP PRE- ENGINEERED OPEN WEB FLR. TRUSSES
SHOWN @ MIN 12'' O.C. / 16'' O.C. TYPICAL THRU-OUT THIS SUPPORT LEVEL
OF SECOND FLOOR ABOVE - ALL FLOOR TRUSSES ARE TO BE VERIFIED BY
THE MANUFACTURERS ENGINEERING DOCUMENTS SUPPLIED TO
PERMITTING DEPT AS FINAL INSTALLED MATERIALS. BUILDER TO USE 1/2''
EXT. SHEAR WALL SHEATHING OVER THE EXTERIOR EXPOSED JOIST OPEN
ENDS TYP. THRU-OUT - USE STRAPPING DETAIL FOR CONTINUOUS
STRAPPING CONNECTION REQUIRED STUD TO FLOOR SYSTEM TO
FOUNDATION. DOUBLE JOIST WHERE WALL SITS ABOVE.
SHOWN AS 3 1/2'' x 16'' DEEP PRE- ENGINEERED OPEN WEB FLR. TRUSSES
SHOWN @ MIN 12'' O.C. / 16'' O.C. TYPICAL THRU-OUT THIS SUPPORT LEVEL
OF SECOND FLOOR ABOVE - ALL FLOOR TRUSSES ARE TO BE VERIFIED BY
THE MANUFACTURERS ENGINEERING DOCUMENTS SUPPLIED TO
PERMITTING DEPT AS FINAL INSTALLED MATERIALS. BUILDER TO USE 1/2''
EXT. SHEAR WALL SHEATHING OVER THE EXTERIOR EXPOSED JOIST OPEN
ENDS TYP. THRU-OUT - USE STRAPPING DETAIL FOR CONTINUOUS
STRAPPING CONNECTION REQUIRED STUD TO FLOOR SYSTEM TO
FOUNDATION. DOUBLE JOIST WHERE WALL SITS ABOVE.
1
A1.10
2
A1.10
1
A1.10
1
A1.10
4
A1.10
4
A1.10
1
A1.10
1
A1.10
1
A1.10
1
A1.10
1
A1.10
1
A1.10
1
A1.10
5
A1.10
5
A1.10
5
A1.10
5
A1.10
5
A1.10
5
A1.10
EXISTING 2X8'' FLOOR
JOIST @ 12'' O.C.
EXISTING 2X8'' FLOOR
JOIST @ 12'' O.C.
EXISTING 2X8'' FLOOR
JOIST @ 12'' O.C.
EXISTING 2X8'' FLOOR
JOIST @ 12'' O.C.
FIRST FLOOR FLOOR SYSTEM SHALL
REMAIN AS IS UNDISTURBED - KEEP AS
EXISTING 2X8'' FLOOR JOIST @ 12'' O.C.
EN
D
O
F
E
X
I
S
T
I
N
G
H
O
U
S
E
NE
W
H
O
U
S
E
F
L
O
O
R
S
Y
S
T
E
M
NEW 2x12'' JOIST (2X8''
USED @ 4'' RECESSED
SHOWER PAN
POURED CONC
POURED CONC
POURED CONC
FI
R
S
T
F
L
O
O
R
F
L
O
O
R
S
Y
S
T
E
M
T
H
I
S
A
R
E
A
S
H
A
L
L
B
E
M
I
N
2
x
1
2
'
'
J
O
I
S
T
@
1
2
'
'
O
.
C
.
OV
E
R
B
A
S
M
E
N
T
S
T
O
R
A
G
E
R
O
O
M
A
R
E
A
B
E
L
O
W
-
S
E
E
F
O
U
N
D
A
T
I
O
N
P
L
A
N
PRINT DATES
FINAL PRINT - 12/09/25
DESIGN DRAWN BY
Kirk A. ThomasKirk A. ThomasKirk A. ThomasKirk A. Thomas
To
t
h
e
b
e
s
t
o
f
m
y
k
n
o
w
l
e
d
g
e
t
h
e
s
e
p
l
a
n
s
a
r
e
d
r
a
w
n
t
o
c
o
m
p
l
y
w
i
t
h
t
h
e
c
o
d
e
r
e
q
u
i
r
e
m
e
n
t
s
f
o
r
th
e
i
r
i
n
t
e
n
d
e
d
u
s
e
b
y
o
w
n
e
r
'
s
a
n
d
/
o
r
b
u
i
l
d
e
r
'
s
s
p
e
c
i
f
i
c
a
t
i
o
n
s
,
a
n
y
c
h
a
n
g
e
s
m
a
d
e
o
n
o
r
t
o
t
h
e
m
af
t
e
r
p
r
i
n
t
s
a
r
e
s
e
a
l
e
d
w
i
l
l
b
e
d
o
n
e
a
t
t
h
e
o
w
n
e
r
'
s
a
n
d
/
o
r
b
u
i
l
d
e
r
'
s
e
x
p
e
n
c
e
a
n
d
r
e
s
p
o
n
s
i
b
i
l
i
t
y
.
Th
e
c
o
n
t
r
a
c
t
o
r
s
h
a
l
l
v
e
r
i
f
y
a
l
l
d
i
m
e
n
s
i
o
n
s
a
n
d
e
n
c
l
o
s
e
d
d
e
t
a
i
l
d
r
a
w
i
n
g
s
.
R
e
f
e
r
I
n
s
t
a
l
l
a
t
i
o
n
o
f
a
l
l
ma
t
e
r
i
a
l
s
t
o
m
a
n
u
f
a
c
t
u
r
e
s
a
n
d
c
o
d
e
r
e
q
u
i
r
m
e
n
t
s
f
o
r
e
a
c
h
i
t
e
m
s
a
t
t
a
c
h
m
e
n
t
t
o
t
h
e
s
t
r
u
c
t
u
r
e
re
q
u
a
r
d
l
e
s
s
o
f
d
e
t
a
i
l
s
h
o
w
n
.
D
e
t
a
i
l
s
a
r
e
n
o
t
s
p
e
c
i
f
i
c
t
o
s
t
r
u
c
t
u
r
e
d
r
a
w
n
,
d
e
t
a
i
l
s
a
r
e
d
r
a
w
n
a
s
pe
r
s
p
e
c
t
i
v
e
c
u
t
a
w
a
y
v
i
e
w
s
a
n
d
i
n
n
o
w
a
y
s
h
o
w
m
a
t
e
r
i
a
l
i
t
e
m
s
a
s
f
i
n
i
s
h
e
d
i
n
s
t
a
l
l
e
d
re
p
r
e
s
e
n
t
a
t
i
o
n
.
k
.
a
.
t
.
D
e
s
i
g
n
s
I
n
c
.
i
s
n
o
t
l
i
a
b
l
e
f
o
r
e
r
r
o
r
s
b
a
s
e
d
u
p
o
n
p
e
r
s
o
n
a
l
i
n
t
e
r
p
r
e
t
a
t
i
o
n
of
a
n
y
d
e
t
a
i
l
,
t
e
x
t
i
t
e
m
,
o
r
s
y
m
b
o
l
u
s
e
d
i
n
t
h
e
c
r
e
a
t
i
o
n
o
f
t
h
e
s
e
d
o
c
u
m
e
n
t
s
.
W
h
i
l
e
e
v
e
r
y
e
f
f
o
r
t
ha
s
b
e
e
n
m
a
d
e
i
n
t
h
e
p
r
e
p
a
r
a
t
i
o
n
o
f
t
h
i
s
p
l
a
n
t
o
a
v
o
i
d
m
i
s
t
a
k
e
s
,
t
h
e
m
a
k
e
r
c
a
n
n
o
t
g
u
a
r
a
n
t
e
e
ag
a
i
n
s
t
h
u
m
a
n
e
r
r
o
r
.
T
h
e
L
i
c
.
C
o
n
t
r
a
c
t
o
r
/
O
w
n
e
r
s
o
f
t
h
e
p
r
o
j
e
c
t
m
u
s
t
c
h
e
c
k
a
l
l
d
i
m
e
n
s
i
o
n
s
a
n
d
de
t
a
i
l
s
p
r
i
o
r
t
o
c
o
n
s
t
r
u
c
t
i
o
n
a
n
d
b
e
s
o
l
e
l
y
r
e
s
p
o
n
s
i
b
l
e
u
p
o
n
i
s
s
u
e
d
p
e
r
m
i
t
.
A
l
l
i
n
f
o
r
m
a
t
i
o
n
co
n
t
a
i
n
e
d
w
i
t
h
i
n
t
h
e
s
e
p
l
a
n
s
i
s
s
u
b
j
e
c
t
t
o
c
h
a
n
g
e
b
a
s
e
o
n
c
o
d
e
r
e
q
u
i
r
e
m
e
n
t
s
a
n
d
p
e
r
m
i
t
t
i
n
g
ju
r
i
s
d
i
c
t
i
o
n
I
n
t
e
r
p
r
e
t
a
t
i
o
n
.
Page #Page #Page #Page #
PL
A
N
S
C
A
L
E
:
BA
S
E
@
1
/
4
"
=
1
'
-
0
'
'
U.
O
.
N
.
S
C
A
L
E
M
A
Y
V
A
R
Y
P
E
R
P
L
A
N
OR
P
E
R
D
E
T
A
I
L
(
N
O
T
S
P
E
C
I
F
I
C
)
Building Code: IRC2018
Design Wind Speed: 130 mph
ASD - ASCE 7-10
Design Wind Speed: 160 MPH
Ultimate - ASCE 7-16
Req. Glazing & Door Design
Pressures (DP's) 50 psf
All Doors and Glazing Installed
shall be Impact Rated
Flood Zone: FIRM - X
Finish Floor Elevation:
Min. 36'' A.CL.RW.
Mean Roof Height:
I,
L
a
r
r
y
M
.
O
l
i
v
e
r
,
P
.
E
.
,
L
i
c
e
n
s
e
N
o
.
1
2
6
7
8
Ce
r
t
i
f
y
t
h
a
t
t
h
e
s
t
r
u
c
t
u
r
a
l
p
o
r
t
i
o
n
s
o
f
t
h
i
s
se
t
o
f
c
o
n
s
t
r
u
c
t
i
o
n
d
o
c
u
m
e
n
t
s
h
a
v
e
b
e
e
n
re
v
i
e
w
e
d
u
n
d
e
r
m
y
r
e
s
p
o
n
s
i
b
l
e
c
h
a
r
g
e
,
de
s
i
n
a
t
e
d
b
y
d
e
s
i
g
n
,
t
o
c
o
m
p
l
y
w
i
t
h
t
h
e
en
g
i
n
e
e
r
i
n
g
r
e
q
u
i
r
e
m
e
n
t
s
o
f
t
h
e
In
t
e
r
n
a
t
i
o
n
a
l
R
e
s
i
d
e
n
t
i
a
l
B
u
i
l
d
i
n
g
C
o
d
e
,
20
1
8
L
a
t
e
s
t
E
d
i
t
i
o
n
@
1
3
0
/
1
6
0
-
m
p
h
3
se
c
g
u
s
t
w
i
n
d
l
o
a
d
r
a
t
i
n
g
.
La
r
r
y
M
.
O
l
i
v
e
r
E
n
t
e
r
p
r
i
s
e
s
I
n
c
.
72
2
8
O
a
k
b
r
i
a
r
D
r
i
v
e
S
o
u
t
h
Mo
b
i
l
e
,
A
L
.
3
6
6
1
9
PE
R
M
I
T
J
U
R
I
S
D
I
C
T
I
O
N
:
CI
T
Y
O
F
F
A
I
R
H
O
P
E
B.
F
.
E
.
:
1
2
'
'
A
.
C
L
.
R
W
FL
O
O
D
Z
O
N
E
:
"
X
"
CO
N
T
R
A
C
T
O
R
:
S
T
E
V
E
J
O
N
E
S
C
O
N
T
R
A
C
T
O
R
PR
OJ
E
C
T
:
R
E
M
O
D
E
L
S
I
N
G
L
E
F
A
M
I
L
Y
R
E
S
.
CL
I
E
N
T
:
L
U
C
I
N
D
A
&
C
H
I
P
C
H
A
P
P
E
L
L
E
LO
C
A
T
I
O
N
:
F
A
I
R
H
O
P
E
,
A
L
.
PH
Y
S
I
C
A
L
A
D
D
R
E
S
S
:
2
1
0
G
A
Y
F
E
R
C
T
.
Base Slab Elev: 24''' A.F.G. (Varies)
FINAL REVIEW - 12/04/25
PRELIM. REVIEW -09/16/25
PRELIM. REVIEW - 11/04/25
PRELIM. REVIEW - 10/07/25
PRELIM. REVIEW -09/17/25
c
2
0
2
5
C
O
P
Y
R
I
G
H
T
B
Y
K
.
A
.
T
.
D
e
s
i
g
n
s
I
n
c
.
T
h
e
s
e
d
r
a
w
i
n
g
s
a
r
e
N
O
T
T
O
B
E
re
p
r
o
d
u
c
e
d
o
r
c
o
p
i
e
d
i
n
a
n
y
f
o
r
m
w
h
a
t
s
o
e
v
e
r
w
i
t
h
o
u
t
t
h
e
w
r
i
t
t
e
n
pe
r
m
i
s
s
i
o
n
o
f
K
.
A
.
T
.
D
e
s
i
g
n
s
I
n
c
.
-
A
N
Y
D
U
P
L
I
C
A
T
I
O
N
I
S
P
R
O
H
I
B
I
T
E
D
A
N
D
PU
N
I
S
H
A
B
L
E
U
N
D
E
R
F
E
D
E
R
A
L
L
A
W
.
T
h
e
p
u
r
c
h
a
s
e
r
h
a
s
t
h
e
r
i
g
h
t
t
o
O
N
E
US
E
f
o
r
p
e
r
m
i
t
t
i
n
g
p
u
r
p
o
s
e
s
,
a
n
y
f
u
t
u
r
e
u
s
e
o
f
t
h
e
p
l
a
n
,
i
d
e
a
s
,
e
l
e
v
a
t
i
o
n
s
,
co
n
t
e
n
t
s
,
o
r
c
h
a
n
g
e
s
t
o
d
e
s
i
g
n
a
r
e
t
h
e
p
r
o
p
e
r
t
y
o
f
K
.
A
.
T
.
D
e
s
i
g
n
s
I
n
c
.
AN
D
M
U
S
T
B
E
A
U
T
H
O
R
I
Z
E
D
B
Y
K
.
A
.
T
.
D
e
s
i
g
n
s
I
n
c
.
A
N
Y
U
N
A
T
H
O
R
I
Z
E
D
U
S
E
WI
L
L
B
E
P
U
N
I
S
H
A
B
L
E
U
N
D
E
R
F
E
D
E
R
A
L
C
O
P
Y
R
I
G
H
T
L
A
W
S
.
FL
O
O
R
T
R
U
S
S
P
L
A
N
L
A
Y
O
U
T
F
O
R
2N
D
F
L
O
O
R
P
L
A
N
S
U
P
P
O
R
T
w
/
OV
E
R
V
I
E
W
,
N
O
T
E
S
&
D
E
T
A
I
L
S
A 1.10A 1.10A 1.10A 1.10
FLOOR SYSTEM FRAMING
OVERVIEW - SCALE 1/8'' = 1'-0''
FLOOR SYSTEM FRAMING -
SCALE 1/4'' = 1'-0''
Page 29 of 63
NO.
8
12
12LTP4
A35 - A35F
A34
SIMPSON
MODEL NO.
8d x 1 1/2"
8d x 1 1/2"
8d x 1 1/2"
FASTENERS
N.T.S.
SHEAR
TRANSFER
DETAIL 33
A1.5N.T.S.
SHEAR TRANSFER DETAIL 11
A1.5
SHEATHING
PER PLAN
FULL LENGTH 8d
COMMON NAILS
THROUGH PLYWOOD.
SIMPSON STRONG
TIE A34 OR A35 AS
SPECIFIED
STUDS PER
PLAN
DBL TOP
PLATE
FIELD
NAILING
PER PLAN
2x BLK'G OR
RIM JOIST
LPT4 MAY BE
INSTALLED
NAILING TYP.
EDGE
RIM JOIST
BLK'G OR
BOUNDARY NAILING
PER PLAN
TRANSFER DETAILS TO BE USED
WHERE BLOCKING OF FLOORS
JOIST OR CEILING JOIST ENDS
EXPOSED AT EXTERIOR WALLS
PER PLAN
PLATE
DBL TOP
STUDS
N.T.S.
SHEAR TRANSFER DETAIL 22
A1.5
SIMPSON
STRONG TIE
A35F OR
LTP4 AS
SPECIFIED
IRC 2018- R802.3.1 - Ceiling joist and rafter connections.
Ceiling joists and rafters shall be nailed/screwed to each other in accordance with Table R802.5.1(9), and the rafter shall be nailed/screwed to the top wall
plate in accordance with Table R602.3(1). Ceiling joists shall be continuous or securely joined in accordance with Table R802.5.1(9) where they meet over
interior partitions and are nailed/screwed to adjacent rafters to provide a continuous tie across the building when such joists are parallel to the rafters.
D/W D/W
REF.
UP
DN
10' 5''
T.O.B.
10
'
5
'
'
T.
O
.
B
.
10' 5''
T.O.B.
2x6
WALL
2x6
WALL
2x6 W
L
10' -1
1
/
8
'
'
2x6
WALL
2x6
WALL
2x4
EXISTING WL
2x
4
@
4
0
'
'
H
G
T
EX
I
S
T
I
N
G
W
L
2x4
EXISTING WL
2x6
WALL
2x6 W
L
10' -1
1
/
8
'
'
2x6 WL
10' -1 1/8''
10' 5''
T.O.B.
2x6 W
L
10' -1
1
/
8
'
'
2x4 W
L
10' -
1
1
/
8
'
'
2x
6
W
L
10
'
-
1
1
/
8
'
'
2x6 W
L
12' -1
1
/
8
'
'
2x4 W
L
12' -1
1
/
8
'
'
2x4 W
L
12' -1
1
/
8
'
'
2x
4
W
L
10
'
-
1
1
/
8
'
'
3 PLY PORCH BEAM
10' -5
3
P
L
Y
1
.
7
8
'
'
x
1
6
'
'
L
V
L
B
E
A
M
SI
T
S
O
N
T
O
P
O
F
1
0
'
B
A
S
E
W
A
L
L
@
E
N
D
S
4
P
L
Y
1
.
7
8
'
'
x
1
6
'
'
L
V
L
B
E
A
M
AT
O
P
1
0
'
W
A
L
L
S
E
C
T
I
O
N
S
@
E
N
D
S
2x6'' CEILING JOIST @ 16'' O.C.
2x6'' CEILING JOIST @ 16'' O.C.
2x6'' CEILING JOIST @ 16'' O.C.
2x6'' CEILING
JOIST @ 16'' O.C.
2x6'' CEILING
JOIST @ 16'' O.C.
2x6'' CEILING
JOIST @ 16'' O.C.
2x6'' CEILING
JOIST @ 16'' O.C.
2x8'' CEILING JOIST @ 16'' O.C.
2x8'' CEILING JOIST @ 16'' O.C.
2x
6
'
'
C
E
I
L
I
N
G
J
O
I
S
T
@
1
6
'
'
O
.
C
.
2x6'' CEILING JOIST @ 16'' O.C.
ATTACHED TO LVL w/ LUS 26 HGR
DBL. BEAMS NOT CONNTECTED
2 PLY 1.78'' x 16'' LVL BEAM
2 PLY 1.78'' x 16'' LVL BEAM
FLOOR TRUSSES THIS AREA
FLOOR TRUSSES THIS AREA
FLOOR TRUSSES THIS AREA
FLOOR TRUSSES
THIS AREA
FLOOR TRUSSES
THIS AREA
FLOOR TRUSSES
THIS AREA
1,2,3,4
A1.11
1,2,3,4
A1.11
5
A1.11
1,2,3,4
A1.11
5
A1.11
1,2,3,4
A1.11
5
A1.11
5
A1.11
1,2,3,4
A1.11
6
A1.11
1,2,3,4
A1.115
A1.11
5
A1.11
5
A1.11
5
A1.11
5
A1.11
5
A1.11
1,2,3,4
A1.11
1,2,3,4
A1.11
5
A1.11
5
A1.11
1,2,3,4
A1.11
1,2,3,4
A1.11
5
A1.11
1,2,3,4
A1.11
6
A1.11
2x8'' CEILING JOIST @ 16'' O.C.
ATTACHED TO LVL w/ LUS 28 HGR
FLOOR TRUSSES THIS AREA
CEILING JOIST & RAFTER TIE TO TOP PLATE
SIMPSON H10
AS SPECIFIED
2x TOP PLATES
RAFTER(S) PER
RAFTER
&
&DC
DCBA
CEILING JOIST
PER PLAN
SHEATHING
H2.5Z OR HS24
SIMPSON 2 @ H2.5,
PLAN (2x MIN)
NOTE: BLOCKING BETWEEN RAFTERS AND ADDITIONAL
SHEAR TRANSFER NOT SHOWN FOR CLARITY. SEE
APPLICABLE DETAILS AS REQUIRED.
ALTERNATE USE CONNECTION (SEE CHART PAGE A1.7)
N.T.S.
PIECE
SIMPSON
H2.5
H2.5Z
H10
H10, H10R
MARK
DETAIL
A
B
C
D 6-10d
6-16d x 2 1/2
8-8d x 1 1/2
6-8d x 1 1/2
FASTENERS - NAILS
4-8d
8-8d x 1 1/2
6-16d x 2 1/2
6-10d
RAFTER TOP PLATE
HS24E 8-8d2-8d SLANT
4
A1.11
H2.5 or
H2.5T
H2.5Z
Clg. Joist Connections to
Wood Top Plates
N.T.S.
see
alternate
methods
5
A1.11
BEAM
2x
JOIST
LUS26
LUS28
16''
LUS210
Simpson Strong-Tie LUS Hangers
FASTERNERS:USE 6 @ 10d NAILS TO
ACHEIVE MIN UPLIFT = 930 #, 16d
NAILS MAX UPLIFT= 1115#
6
A1.11
DN
REF.
UP
8'
1
'
'
W
A
L
L
H
G
T
A
T
T
H
I
S
S
I
D
E
8'1
'
'
W
A
L
L
H
G
T
A
T
T
H
I
S
A
R
E
A
LI
N
E
O
F
8
'
V
A
L
L
E
Y
A
R
E
A
LI
N
E
O
F
8
'
C
E
I
L
I
N
G
LI
N
E
O
F
8
'
C
E
I
L
I
N
G
8'
B
A
S
E
H
G
T
9' CENTER HGT
8' - CLG HGT
8' - CLG HGT
LINE OF 8' VALLY AREA
CE
I
L
I
N
G
S
L
O
P
E
S
WI
T
H
S
T
A
I
R
S
LIN
CAB
30'' SINK BASE
3x5 TILE
SHWR
15''
DR
STK
15''
DR
STK
60'' VANITY
36
'
'
K
.
W
.
S
U
P
@
E
X
T
.
B
R
G
.
36
'
'
K
.
W
.
S
U
P
@
E
X
T
.
B
R
G
.
60
'
'
K
.
W
.
S
U
P
@
I
N
T
.
B
R
G
.
60
'
'
K
.
W
.
S
U
P
@
I
N
T
.
B
R
G
.
SLOPE TO 8'SLOPE TO 8'
SLOPE TO 8'SLOPE TO 8'
SLOPE
SLOPE
8' - CLG HGT
2x6 CEILING JOIST
@ 16'' O.C.
RO
O
F
R
A
F
T
E
R
S
A
R
E
CE
I
L
I
N
G
J
O
I
S
T
T
H
I
S
A
R
E
A
RO
O
F
R
A
F
T
E
R
S
A
R
E
CEI
L
I
N
G
J
O
I
S
T
T
H
I
S
A
R
E
A
RO
O
F
R
A
F
T
E
R
S
AR
E
C
E
I
L
I
N
G
JO
I
S
T
T
H
I
S
A
R
E
A
2
P
L
Y
1
.
7
8
'
'
x
1
1
.
7
8
'
'
L
V
L
B
E
A
M
AT
O
P
W
A
L
L
S
E
C
T
I
O
N
S
@
E
N
D
S
2
P
L
Y
1
.
7
8
'
'
x
1
1
.
7
8
'
'
L
V
L
B
E
A
M
AT
O
P
W
A
L
L
S
E
C
T
I
O
N
S
@
E
N
D
S
2
P
L
Y
1
.
7
8
'
'
x
1
1
.
7
8
'
'
L
V
L
B
E
A
M
AT
O
P
W
A
L
L
S
E
C
T
I
O
N
S
@
E
N
D
S
2x8 CEILING JOIST
@ 16'' O.C.
2x6 CEILING JOIST
@ 16'' O.C.
th
i
s
s
i
d
e
s
l
i
g
h
t
s
l
o
p
e
t
o
8
'
c
l
g
h
g
t
.
3 PLY 1.78'' x 11.78'' LVL BEAM - ATOP WALL SECTIONS @ ENDS w/1/2'' FLITCH PLT
2X4 FILLERS @ 24'' O.C.
2X4 FILLERS @ 24'' O.C.
2X
4
F
I
L
L
E
R
S
@
2
4
'
'
O
.
C
.
2X
4
F
I
L
L
E
R
S
@
2
4
'
'
O
.
C
.
3 PLY 1.78'' x 11.78'' LVL BEAM - ATOP WALL SECTIONS @ ENDS w/1/2'' FLITCH PLT
1,2,3,4
A1.11
5
A1.11
5
A1.11
1,2,3,4
A1.11
6
A1.11
LUS JOIST HGR
6
A1.11
6
A1.11
5
A1.11
5
A1.11
1,2,3,4
A1.11
8'
B
A
S
E
H
G
T
8' BASE HGT
8' BASE HGT
5
A1.11
1,2,3,4
A1.11
1,2,3,4
A1.11
5
A1.11
2X6 CLG JOIST @ 24'' O.C.
PRINT DATES
FINAL PRINT - 12/09/25
DESIGN DRAWN BY
Kirk A. ThomasKirk A. ThomasKirk A. ThomasKirk A. Thomas
To
t
h
e
b
e
s
t
o
f
m
y
k
n
o
w
l
e
d
g
e
t
h
e
s
e
p
l
a
n
s
a
r
e
d
r
a
w
n
t
o
c
o
m
p
l
y
w
i
t
h
t
h
e
c
o
d
e
r
e
q
u
i
r
e
m
e
n
t
s
f
o
r
th
e
i
r
i
n
t
e
n
d
e
d
u
s
e
b
y
o
w
n
e
r
'
s
a
n
d
/
o
r
b
u
i
l
d
e
r
'
s
s
p
e
c
i
f
i
c
a
t
i
o
n
s
,
a
n
y
c
h
a
n
g
e
s
m
a
d
e
o
n
o
r
t
o
t
h
e
m
af
t
e
r
p
r
i
n
t
s
a
r
e
s
e
a
l
e
d
w
i
l
l
b
e
d
o
n
e
a
t
t
h
e
o
w
n
e
r
'
s
a
n
d
/
o
r
b
u
i
l
d
e
r
'
s
e
x
p
e
n
c
e
a
n
d
r
e
s
p
o
n
s
i
b
i
l
i
t
y
.
Th
e
c
o
n
t
r
a
c
t
o
r
s
h
a
l
l
v
e
r
i
f
y
a
l
l
d
i
m
e
n
s
i
o
n
s
a
n
d
e
n
c
l
o
s
e
d
d
e
t
a
i
l
d
r
a
w
i
n
g
s
.
R
e
f
e
r
I
n
s
t
a
l
l
a
t
i
o
n
o
f
a
l
l
ma
t
e
r
i
a
l
s
t
o
m
a
n
u
f
a
c
t
u
r
e
s
a
n
d
c
o
d
e
r
e
q
u
i
r
m
e
n
t
s
f
o
r
e
a
c
h
i
t
e
m
s
a
t
t
a
c
h
m
e
n
t
t
o
t
h
e
s
t
r
u
c
t
u
r
e
re
q
u
a
r
d
l
e
s
s
o
f
d
e
t
a
i
l
s
h
o
w
n
.
D
e
t
a
i
l
s
a
r
e
n
o
t
s
p
e
c
i
f
i
c
t
o
s
t
r
u
c
t
u
r
e
d
r
a
w
n
,
d
e
t
a
i
l
s
a
r
e
d
r
a
w
n
a
s
pe
r
s
p
e
c
t
i
v
e
c
u
t
a
w
a
y
v
i
e
w
s
a
n
d
i
n
n
o
w
a
y
s
h
o
w
m
a
t
e
r
i
a
l
i
t
e
m
s
a
s
f
i
n
i
s
h
e
d
i
n
s
t
a
l
l
e
d
re
p
r
e
s
e
n
t
a
t
i
o
n
.
k
.
a
.
t
.
D
e
s
i
g
n
s
I
n
c
.
i
s
n
o
t
l
i
a
b
l
e
f
o
r
e
r
r
o
r
s
b
a
s
e
d
u
p
o
n
p
e
r
s
o
n
a
l
i
n
t
e
r
p
r
e
t
a
t
i
o
n
of
a
n
y
d
e
t
a
i
l
,
t
e
x
t
i
t
e
m
,
o
r
s
y
m
b
o
l
u
s
e
d
i
n
t
h
e
c
r
e
a
t
i
o
n
o
f
t
h
e
s
e
d
o
c
u
m
e
n
t
s
.
W
h
i
l
e
e
v
e
r
y
e
f
f
o
r
t
ha
s
b
e
e
n
m
a
d
e
i
n
t
h
e
p
r
e
p
a
r
a
t
i
o
n
o
f
t
h
i
s
p
l
a
n
t
o
a
v
o
i
d
m
i
s
t
a
k
e
s
,
t
h
e
m
a
k
e
r
c
a
n
n
o
t
g
u
a
r
a
n
t
e
e
ag
a
i
n
s
t
h
u
m
a
n
e
r
r
o
r
.
T
h
e
L
i
c
.
C
o
n
t
r
a
c
t
o
r
/
O
w
n
e
r
s
o
f
t
h
e
p
r
o
j
e
c
t
m
u
s
t
c
h
e
c
k
a
l
l
d
i
m
e
n
s
i
o
n
s
a
n
d
de
t
a
i
l
s
p
r
i
o
r
t
o
c
o
n
s
t
r
u
c
t
i
o
n
a
n
d
b
e
s
o
l
e
l
y
r
e
s
p
o
n
s
i
b
l
e
u
p
o
n
i
s
s
u
e
d
p
e
r
m
i
t
.
A
l
l
i
n
f
o
r
m
a
t
i
o
n
co
n
t
a
i
n
e
d
w
i
t
h
i
n
t
h
e
s
e
p
l
a
n
s
i
s
s
u
b
j
e
c
t
t
o
c
h
a
n
g
e
b
a
s
e
o
n
c
o
d
e
r
e
q
u
i
r
e
m
e
n
t
s
a
n
d
p
e
r
m
i
t
t
i
n
g
ju
r
i
s
d
i
c
t
i
o
n
I
n
t
e
r
p
r
e
t
a
t
i
o
n
.
Page #Page #Page #Page #
PL
A
N
S
C
A
L
E
:
BA
S
E
@
1
/
4
"
=
1
'
-
0
'
'
U.
O
.
N
.
S
C
A
L
E
M
A
Y
V
A
R
Y
P
E
R
P
L
A
N
OR
P
E
R
D
E
T
A
I
L
(
N
O
T
S
P
E
C
I
F
I
C
)
Building Code: IRC2018
Design Wind Speed: 130 mph
ASD - ASCE 7-10
Design Wind Speed: 160 MPH
Ultimate - ASCE 7-16
Req. Glazing & Door Design
Pressures (DP's) 50 psf
All Doors and Glazing Installed
shall be Impact Rated
Flood Zone: FIRM - X
Finish Floor Elevation:
Min. 36'' A.CL.RW.
Mean Roof Height:
I,
L
a
r
r
y
M
.
O
l
i
v
e
r
,
P
.
E
.
,
L
i
c
e
n
s
e
N
o
.
1
2
6
7
8
Ce
r
t
i
f
y
t
h
a
t
t
h
e
s
t
r
u
c
t
u
r
a
l
p
o
r
t
i
o
n
s
o
f
t
h
i
s
se
t
o
f
c
o
n
s
t
r
u
c
t
i
o
n
d
o
c
u
m
e
n
t
s
h
a
v
e
b
e
e
n
re
v
i
e
w
e
d
u
n
d
e
r
m
y
r
e
s
p
o
n
s
i
b
l
e
c
h
a
r
g
e
,
de
s
i
n
a
t
e
d
b
y
d
e
s
i
g
n
,
t
o
c
o
m
p
l
y
w
i
t
h
t
h
e
en
g
i
n
e
e
r
i
n
g
r
e
q
u
i
r
e
m
e
n
t
s
o
f
t
h
e
In
t
e
r
n
a
t
i
o
n
a
l
R
e
s
i
d
e
n
t
i
a
l
B
u
i
l
d
i
n
g
C
o
d
e
,
20
1
8
L
a
t
e
s
t
E
d
i
t
i
o
n
@
1
3
0
/
1
6
0
-
m
p
h
3
se
c
g
u
s
t
w
i
n
d
l
o
a
d
r
a
t
i
n
g
.
La
r
r
y
M
.
O
l
i
v
e
r
E
n
t
e
r
p
r
i
s
e
s
I
n
c
.
72
2
8
O
a
k
b
r
i
a
r
D
r
i
v
e
S
o
u
t
h
Mo
b
i
l
e
,
A
L
.
3
6
6
1
9
PE
R
M
I
T
J
U
R
I
S
D
I
C
T
I
O
N
:
CI
T
Y
O
F
F
A
I
R
H
O
P
E
B.
F
.
E
.
:
1
2
'
'
A
.
C
L
.
R
W
FL
O
O
D
Z
O
N
E
:
"
X
"
CO
N
T
R
A
C
T
O
R
:
S
T
E
V
E
J
O
N
E
S
C
O
N
T
R
A
C
T
O
R
PR
OJ
E
C
T
:
R
E
M
O
D
E
L
S
I
N
G
L
E
F
A
M
I
L
Y
R
E
S
.
CL
I
E
N
T
:
L
U
C
I
N
D
A
&
C
H
I
P
C
H
A
P
P
E
L
L
E
LO
C
A
T
I
O
N
:
F
A
I
R
H
O
P
E
,
A
L
.
PH
Y
S
I
C
A
L
A
D
D
R
E
S
S
:
2
1
0
G
A
Y
F
E
R
C
T
.
Base Slab Elev: 24''' A.F.G. (Varies)
FINAL REVIEW - 12/04/25
PRELIM. REVIEW -09/16/25
PRELIM. REVIEW - 11/04/25
PRELIM. REVIEW - 10/07/25
PRELIM. REVIEW -09/17/25
c
2
0
2
5
C
O
P
Y
R
I
G
H
T
B
Y
K
.
A
.
T
.
D
e
s
i
g
n
s
I
n
c
.
T
h
e
s
e
d
r
a
w
i
n
g
s
a
r
e
N
O
T
T
O
B
E
re
p
r
o
d
u
c
e
d
o
r
c
o
p
i
e
d
i
n
a
n
y
f
o
r
m
w
h
a
t
s
o
e
v
e
r
w
i
t
h
o
u
t
t
h
e
w
r
i
t
t
e
n
pe
r
m
i
s
s
i
o
n
o
f
K
.
A
.
T
.
D
e
s
i
g
n
s
I
n
c
.
-
A
N
Y
D
U
P
L
I
C
A
T
I
O
N
I
S
P
R
O
H
I
B
I
T
E
D
A
N
D
PU
N
I
S
H
A
B
L
E
U
N
D
E
R
F
E
D
E
R
A
L
L
A
W
.
T
h
e
p
u
r
c
h
a
s
e
r
h
a
s
t
h
e
r
i
g
h
t
t
o
O
N
E
US
E
f
o
r
p
e
r
m
i
t
t
i
n
g
p
u
r
p
o
s
e
s
,
a
n
y
f
u
t
u
r
e
u
s
e
o
f
t
h
e
p
l
a
n
,
i
d
e
a
s
,
e
l
e
v
a
t
i
o
n
s
,
co
n
t
e
n
t
s
,
o
r
c
h
a
n
g
e
s
t
o
d
e
s
i
g
n
a
r
e
t
h
e
p
r
o
p
e
r
t
y
o
f
K
.
A
.
T
.
D
e
s
i
g
n
s
I
n
c
.
AN
D
M
U
S
T
B
E
A
U
T
H
O
R
I
Z
E
D
B
Y
K
.
A
.
T
.
D
e
s
i
g
n
s
I
n
c
.
A
N
Y
U
N
A
T
H
O
R
I
Z
E
D
U
S
E
WI
L
L
B
E
P
U
N
I
S
H
A
B
L
E
U
N
D
E
R
F
E
D
E
R
A
L
C
O
P
Y
R
I
G
H
T
L
A
W
S
.
CO
N
V
E
N
T
I
O
N
A
L
F
R
A
M
E
D
C
E
I
L
I
N
G
JO
I
S
T
P
L
A
N
w
/
N
O
T
E
S
&
D
E
T
A
I
L
S
A 1.11A 1.11A 1.11A 1.11
1ST FLR. CEILING JOIST FRAMING
OVERVIEW - SCALE 1/8'' = 1'-0''
2ND FLR. CEILING JOIST FRAMING
OVERVIEW - SCALE 3/16'' = 1'-0''
1ST FLR. CEILING JOIST FRAMING PLAN - SCALE 1/4'' = 1'-0''
2nd FLR. CEILING JOIST FRAMING
PLAN - SCALE 1/4'' = 1'-0''
Page 30 of 63
SIMPSON STRONG TIE H10
HURRICANE TIE FASTENED
WITH (18) STRONG -DRIVE
SDS HEAVY - DUTY
CONNECTOR SCREWS
2'' = 1'-0''
RAFTER TO TOP PLATE CON.
SP1 - Stud
to Top Plt
H2.5 Ceiling
Joist to Top
Plt
H2.5 Stud to
Top Plt
optional use items shown
1
A1.12
1'
-
8
"
Ridge Beam As
Specified
16d @ 6" O.C.
ROOF RAFTER COLAR TIE FRAMING CON.
19/32" Min. APA
Roof Sheathing
Sheathing over
Peel & Stick
weather proof
membrane
2x6" or 8'' Rafter @ 16'' O.C.
2x6" COLLAR TIE @ EA RAFTER
OPT. 1/2'' PLY WD.
GUSSET @ EA RAFTER
N.T.S.
2
A1.12
2x6" or 8'' Rafter @ 16'' O.C.
see specific rafters as per plan
SIMPSON STRONG TIE RBC FASTENED WITH
(12) 0.148'' X 1-1/2'' NAILS @ 16'' O.C.
BLOCKING JOIST OR
RAFTER PER PLAN
DBL TOP
PLATE
2x STUDS
PLY WD/ OSB SHEATHING - SEE NAILING SCHEDULE
RAFTER or TRUSS
@ 24'' O.C.
ROOF BOUNDARY CLIP DETAIL6
A1.12 N.T.S.
H10
H8One
H2.5A
Two
H2.5A
SDWC Narrow Face
ofStud-to-Top Plate
Connection (This
application requires
SDWC15600)
H8
SP4
MTS12
(LTS, HTS
similar)
High Wind hold downs: Rafter -
Clg. Joist connections shown .
They shall be installed on the
same side of the wall as
plate-to-stud connectors.
Rafter & Stud to Top Plate Con.
N.T.S.
3
A1.12 This detail gives the builder the option to use one of the shown connections on
either the rafter or ceiling joist, to top plate, not both on one framing member.
4
A1.12 1 1/2'' = 1'-0''
45 MAX.
2" X 4" NAILER w/2-16d
RS NAILS AT 12" O.C.
DOUBLE 2" X TOP PLATE
2" X BLOCKING
2" X STUD WALL
FRAMING @ 16" O.C.
GABLE END BRACING DETAIL
8d RS @ 3" O.C.2" X 4" @ EA. GABLE
VERTICAL > 4'-0" IN
HEIGHT (NAILED w/
8d RS NAILS @ 6"
O.C.-3'' O.C. ANCHOR
@ PLATE w/ H2.5
CLIP)
GABLE END
(7/16 OSB)
NORBOARD
WINDSTORM
SHEATHING TOP
OF RAFTER TO
BASE PLATE @
SLAB 2' MIN.
TO
SPLICE
1/2" DRYWALL CEILING w/1 1/4''
DRYWALL SCREWS AT 6" O.C.
2" X 4" BLOCKING @ 4' O.C.
TOP AND BOTTOM w/3-16d RS
NAILS @ EA. END
CONTINUOUS 2" X 4" LATERAL
BRACE @ min. 8'-0''
RAFTERS @ 24" O.C.
2" X 4' DIAGONAL BRACING @
min. 8'-0'' w/3-16d RS NAILS
Note:
ALL SCREWS MIN.
3/4" FROM EDGE
VALLEY FRAMING DETAIL
SDWC SCREWS
@ 6'' O.C.
2x Solid Blocking
Roof
Roofing: Customer Choice
Sheathing: 19/32" Min. Marked for 16" spans.
Note No vents in protected area.
Block all horozonal panel edges. Gypsun board
must be nailed @ 7" O.C.. Fiberboard--1/2" for studs 16" O.C.
2x6'' OR 8'' #2 Rafter
INSTALL
FLASHING AS
REQUIRED
N.T.S.
7
A 1.12
2x6'' OR 8'' #2 Rafter
Rafter
Rafter
(2)
SDWC15600
overhang
21
21
5
A1.12
SDWC 15600 - RAFTER TO TOP PLATE CON.
N.T.S.
PROFILE END
(2)
SDWC15600 DBL
TOP
PLT
Opt use Detail
ROOF FRAMING NOTES:
-----------------------------------------
1: APPLY 2x6 COLAR TIES TO ALL 2x6'' & 8'' & 10'' RAFTER FRAMING MEMBERS IN MAIN BODY CENTER
STRUCTURE MIN. 24" BELOW RIDGE BEAM TO MAINTAIN PROPER CEILING HGT IN ATTIC RM. @ 8' -1''.
#2: APPLY 2x6 COLAR TIES TO ALL RAFTER FRAMING MEMBERS IN ATTIC RM. ROOF STRUCTURE 24" BELOW
RIDGE BEAM IN VAULTED PATIO CEILING.
#3: APPLY 2x6 PURLINS w/ 2x6 syp VERTICAL SUPPORTS w/ (T -TYPE) BACKERS TO BEARING WALL EVERY 10'
O.C. ON SPANS OVER 16' IN LENGTH OF RUN. IF PLATE SUPPORT IS NOT AVAILABLE APPLY (K-TYPE) FRAMING
TO LATERIAL FRAMING MEMBER DIRECTIONAL TO NEAREST BEARING WALL SECTION.
#4: ALL OUT-LOOKERS TO BE 2x4 SYP MIN. UNLESS NOTED OTHERWISE.
#5: ALL RAFTERS TO PLATE CONNECTIONS MUST MAINTAIN STANDARD UPLIFT REQUIRMENTS WITH MIN. (H-10
RAFTER TO TOP PLATE & H2.5 CLIP CEILING JOIST TO TOP PLATE - FILL ALL NAIL HOLES w/ #10 d NAILS or
SCREWS AS NOTED IN ALTERNATE CHART.)
D/W D/W
REF.
UP
DN
10' 5''
T.O.B.
10
'
5
'
'
T.
O
.
B
.
10' 5''
T.O.B.
2x6
WALL
2x6
WALL
2x6 W
L
10' -1
1
/
8
'
'
2x6
WALL
2x6
WALL
2x4
EXISTING WL
2x
4
@
4
0
'
'
H
G
T
EX
I
S
T
I
N
G
W
L
2x4
EXISTING WL
2x6
WALL
2x6 W
L
10' -1
1
/
8
'
'
2x6 WL
10' -1 1/8''
10' 5''
T.O.B.
2x6 W
L
10' -1
1
/
8
'
'
2x4 W
L
10' -
1
1
/
8
'
'
2x
6
W
L
10
'
-
1
1
/
8
'
'
2x6 W
L
12' -1
1
/
8
'
'
2x4 W
L
12' -1
1
/
8
'
'
2x4 W
L
12' -1
1
/
8
'
'
2x
4
W
L
10
'
-
1
1
/
8
'
'
3 PLY PORCH BEAM
10' -5
2x
1
2
'
'
#
2
R
I
D
G
E
B
E
A
M
2x
6
'
'
#
2
R
A
F
T
E
R
S
@
16
'
'
O
.
C
.
T
Y
P
2x6'' #2 RAFTERS
@ 16'' O.C. TYP
CEILINGS THIS FLOOR LEVEL SHALL BE MIN. 10'-1 1/8'' FINISHED CLG. HGT TYP TO TOP
OF PLATE - REFER TO BEARING AT EXTERIOR WALLS. (SEE FRAMING VIEWS)
ROOF FRAMING PLAN:SHALL BE 2x6'' & 2X8'' #2 RAFTERS @ 16" O.C. TYP
THROUGHOUT w/16'' O.H. TYP. T.O. - HIP RIDGE RAFTERS SHALL BE MIN 2x6'' , 10'' &
12'' HIP RIDGE BEAMS - MAIN ROOF PITCH @ 8/12 - REAR GABLE ROOF @ 8/12 PITCH.
ALL RAFTERS SHALLL BE ATTACHED TO DBL. TOP PLATE w/MIN SIMPSON H-10 OR
EQUIVILANT TYPE CONNECTOR. BRACE PER REQ. SEE DETAIL USE DETAIL (5 A1.12 IN
LIEU OF H -10s) APPLY DETAIL (6 -A1.12 TO ALL EXTERIOR WALL SECTIONS TO
SHEATHING CONECTIONS WHERE 2 FT KNEE WALL WAS CONSTRUCTED.)
16
'
'
o
.
h
.
T
y
p
.
A
f
t
e
r
F
i
n
i
s
h
e
d
B
r
i
c
k
-
F
l
u
s
h
H
a
r
d
i
e
S
o
f
f
i
t
m
a
t
e
r
i
a
l
-
i
n
s
t
a
l
l
e
d
p
e
r
2
0
1
8
I
R
C
r
e
q
.
16
'
'
o
.
h
.
T
y
p
.
A
f
t
e
r
F
i
n
i
s
h
e
d
B
r
i
c
k
-
F
l
u
s
h
H
a
r
d
i
e
S
o
f
f
i
t
m
a
t
e
r
i
a
l
-
i
n
s
t
a
l
l
e
d
p
e
r
2
0
1
8
I
R
C
r
e
q
.
16'' o.h. Typ. After Finished Brick - Flush Hardie Soffit material - installed per 2018 IRC req.
16'' o.h. Typ. After Finished Brick - Flush Hardie Soffit material - installed per 2018 IRC req.
16
'
'
o
.
h
.
T
y
p
.
A
f
t
e
r
F
i
n
i
s
h
e
d
B
r
i
c
k
-
F
l
u
s
h
H
a
r
d
i
e
S
o
f
f
i
t
ma
t
e
r
i
a
l
-
i
n
s
t
a
l
l
e
d
p
e
r
2
0
1
8
I
R
C
r
e
q
.
16'' o.h. Typ. After Finished Brick - Flush Hardie Soffit material - installed per 2018 IRC req.
16'' o.h. Typ. After Finished Brick - Flush Hardie
Soffit material - installed per 2018 IRC req.12'' o.h. Typ. After Finished Brick -
Flush Hardie Soffit material -
installed per 2018 IRC req.
2x
8
'
'
#
2
R
A
F
T
E
R
S
@
16
'
'
O
.
C
.
T
Y
P
2x
8
'
'
#
2
R
A
F
T
E
R
S
@
16
'
'
O
.
C
.
T
Y
P
2x8
'' VAL
L
EY RAFTER
2x8''
HIP R
A
F
T
E
R
2x6''
RAFTERS @
16'' O.C.
2x6''
RAFTERS @
16'' O.C.
2x8''
H
I
P
R
A
F
T
E
R
2x8''
H
I
P
R
A
F
T
E
R
2x6
'
'
RAFT
E
R
S
@
1
6
'
'
O.C.
2x6'' HI
P
RA
F
T
ER
2x6'' HI
P
RA
F
T
ER
2x6'' RAFTERS @ 16'' O.C.
2x6'' RAFTERS @ 16'' O.C.
2x
8
'
'
R
A
F
T
E
R
S
@
1
6
'
'
O
.
C
.
2x8'' HI
P
RA
F
T
ER
2x8'' HI
P
RA
F
T
ER
2x6'' #2 RAFTERS
@ 16'' O.C. TYP 2x6'' #2 RAFTERS
@ 16'' O.C. TYP
2x6'' #2 R
A
F
TERS
@
16'' O.
C
.
T
YP 2x6'' #2 RAFTERS @ 16'' O.C. TYP
2x
1
2
'
'
#
2
R
I
D
G
E
B
E
A
M
2x8'' VALLEY R
A
F
T
ER
2x6'' #2 RAFTERS
@ 16'' O.C. TYP
2x12'' #2 RIDGE BEAM
2x8'' HI
P
RA
F
T
ER
2x8'' #2 RAFTERS
@ 16'' O.C. TYP 2x6
'' RA
F
TER
S
@
16'' O.C.
2x8'' #
2
H
I
P
R
IDGE RAFT
E
R
2x8'' HI
P
RA
F
T
ER
2x
1
0
'
'
#
2
R
I
D
G
E
B
E
A
M
1-3
A1.12
1-3
A1.12
LTS
20LTS
20
LTS
20
LTS
20
2
A1.12
2
A1.12
2
A1.12
2
A1.12
2
A1.12
2
A1.12
2
A1.12
4
A1.12
1-3
A1.12
1-3
A1.12
1-3
A1.12
1-3
A1.12
7
A1.12
7
A1.12
7
A1.12
7
A1.12
7
A1.12
7
A1.12
7
A1.12
7
A1.12
7
A1.12
7
A1.12
2x6
'' VALLEY RAFT
ER
2x6
'' VAL
L
EY RAFTER
4
A1.12
4
A1.12
4
A1.12
1-3
A1.12
1-3
A1.12
LUS
20
1-3
A1.12
1-3
A1.12
1-3
A1.12
1-3
A1.12
PRINT DATES
FINAL PRINT - 12/09/25
DESIGN DRAWN BY
Kirk A. ThomasKirk A. ThomasKirk A. ThomasKirk A. Thomas
To
t
h
e
b
e
s
t
o
f
m
y
k
n
o
w
l
e
d
g
e
t
h
e
s
e
p
l
a
n
s
a
r
e
d
r
a
w
n
t
o
c
o
m
p
l
y
w
i
t
h
t
h
e
c
o
d
e
r
e
q
u
i
r
e
m
e
n
t
s
f
o
r
th
e
i
r
i
n
t
e
n
d
e
d
u
s
e
b
y
o
w
n
e
r
'
s
a
n
d
/
o
r
b
u
i
l
d
e
r
'
s
s
p
e
c
i
f
i
c
a
t
i
o
n
s
,
a
n
y
c
h
a
n
g
e
s
m
a
d
e
o
n
o
r
t
o
t
h
e
m
af
t
e
r
p
r
i
n
t
s
a
r
e
s
e
a
l
e
d
w
i
l
l
b
e
d
o
n
e
a
t
t
h
e
o
w
n
e
r
'
s
a
n
d
/
o
r
b
u
i
l
d
e
r
'
s
e
x
p
e
n
c
e
a
n
d
r
e
s
p
o
n
s
i
b
i
l
i
t
y
.
Th
e
c
o
n
t
r
a
c
t
o
r
s
h
a
l
l
v
e
r
i
f
y
a
l
l
d
i
m
e
n
s
i
o
n
s
a
n
d
e
n
c
l
o
s
e
d
d
e
t
a
i
l
d
r
a
w
i
n
g
s
.
R
e
f
e
r
I
n
s
t
a
l
l
a
t
i
o
n
o
f
a
l
l
ma
t
e
r
i
a
l
s
t
o
m
a
n
u
f
a
c
t
u
r
e
s
a
n
d
c
o
d
e
r
e
q
u
i
r
m
e
n
t
s
f
o
r
e
a
c
h
i
t
e
m
s
a
t
t
a
c
h
m
e
n
t
t
o
t
h
e
s
t
r
u
c
t
u
r
e
re
q
u
a
r
d
l
e
s
s
o
f
d
e
t
a
i
l
s
h
o
w
n
.
D
e
t
a
i
l
s
a
r
e
n
o
t
s
p
e
c
i
f
i
c
t
o
s
t
r
u
c
t
u
r
e
d
r
a
w
n
,
d
e
t
a
i
l
s
a
r
e
d
r
a
w
n
a
s
pe
r
s
p
e
c
t
i
v
e
c
u
t
a
w
a
y
v
i
e
w
s
a
n
d
i
n
n
o
w
a
y
s
h
o
w
m
a
t
e
r
i
a
l
i
t
e
m
s
a
s
f
i
n
i
s
h
e
d
i
n
s
t
a
l
l
e
d
re
p
r
e
s
e
n
t
a
t
i
o
n
.
k
.
a
.
t
.
D
e
s
i
g
n
s
I
n
c
.
i
s
n
o
t
l
i
a
b
l
e
f
o
r
e
r
r
o
r
s
b
a
s
e
d
u
p
o
n
p
e
r
s
o
n
a
l
i
n
t
e
r
p
r
e
t
a
t
i
o
n
of
a
n
y
d
e
t
a
i
l
,
t
e
x
t
i
t
e
m
,
o
r
s
y
m
b
o
l
u
s
e
d
i
n
t
h
e
c
r
e
a
t
i
o
n
o
f
t
h
e
s
e
d
o
c
u
m
e
n
t
s
.
W
h
i
l
e
e
v
e
r
y
e
f
f
o
r
t
ha
s
b
e
e
n
m
a
d
e
i
n
t
h
e
p
r
e
p
a
r
a
t
i
o
n
o
f
t
h
i
s
p
l
a
n
t
o
a
v
o
i
d
m
i
s
t
a
k
e
s
,
t
h
e
m
a
k
e
r
c
a
n
n
o
t
g
u
a
r
a
n
t
e
e
ag
a
i
n
s
t
h
u
m
a
n
e
r
r
o
r
.
T
h
e
L
i
c
.
C
o
n
t
r
a
c
t
o
r
/
O
w
n
e
r
s
o
f
t
h
e
p
r
o
j
e
c
t
m
u
s
t
c
h
e
c
k
a
l
l
d
i
m
e
n
s
i
o
n
s
a
n
d
de
t
a
i
l
s
p
r
i
o
r
t
o
c
o
n
s
t
r
u
c
t
i
o
n
a
n
d
b
e
s
o
l
e
l
y
r
e
s
p
o
n
s
i
b
l
e
u
p
o
n
i
s
s
u
e
d
p
e
r
m
i
t
.
A
l
l
i
n
f
o
r
m
a
t
i
o
n
co
n
t
a
i
n
e
d
w
i
t
h
i
n
t
h
e
s
e
p
l
a
n
s
i
s
s
u
b
j
e
c
t
t
o
c
h
a
n
g
e
b
a
s
e
o
n
c
o
d
e
r
e
q
u
i
r
e
m
e
n
t
s
a
n
d
p
e
r
m
i
t
t
i
n
g
ju
r
i
s
d
i
c
t
i
o
n
I
n
t
e
r
p
r
e
t
a
t
i
o
n
.
Page #Page #Page #Page #
PL
A
N
S
C
A
L
E
:
BA
S
E
@
1
/
4
"
=
1
'
-
0
'
'
U.
O
.
N
.
S
C
A
L
E
M
A
Y
V
A
R
Y
P
E
R
P
L
A
N
OR
P
E
R
D
E
T
A
I
L
(
N
O
T
S
P
E
C
I
F
I
C
)
Building Code: IRC2018
Design Wind Speed: 130 mph
ASD - ASCE 7-10
Design Wind Speed: 160 MPH
Ultimate - ASCE 7-16
Req. Glazing & Door Design
Pressures (DP's) 50 psf
All Doors and Glazing Installed
shall be Impact Rated
Flood Zone: FIRM - X
Finish Floor Elevation:
Min. 36'' A.CL.RW.
Mean Roof Height:
I,
L
a
r
r
y
M
.
O
l
i
v
e
r
,
P
.
E
.
,
L
i
c
e
n
s
e
N
o
.
1
2
6
7
8
Ce
r
t
i
f
y
t
h
a
t
t
h
e
s
t
r
u
c
t
u
r
a
l
p
o
r
t
i
o
n
s
o
f
t
h
i
s
se
t
o
f
c
o
n
s
t
r
u
c
t
i
o
n
d
o
c
u
m
e
n
t
s
h
a
v
e
b
e
e
n
re
v
i
e
w
e
d
u
n
d
e
r
m
y
r
e
s
p
o
n
s
i
b
l
e
c
h
a
r
g
e
,
de
s
i
n
a
t
e
d
b
y
d
e
s
i
g
n
,
t
o
c
o
m
p
l
y
w
i
t
h
t
h
e
en
g
i
n
e
e
r
i
n
g
r
e
q
u
i
r
e
m
e
n
t
s
o
f
t
h
e
In
t
e
r
n
a
t
i
o
n
a
l
R
e
s
i
d
e
n
t
i
a
l
B
u
i
l
d
i
n
g
C
o
d
e
,
20
1
8
L
a
t
e
s
t
E
d
i
t
i
o
n
@
1
3
0
/
1
6
0
-
m
p
h
3
se
c
g
u
s
t
w
i
n
d
l
o
a
d
r
a
t
i
n
g
.
La
r
r
y
M
.
O
l
i
v
e
r
E
n
t
e
r
p
r
i
s
e
s
I
n
c
.
72
2
8
O
a
k
b
r
i
a
r
D
r
i
v
e
S
o
u
t
h
Mo
b
i
l
e
,
A
L
.
3
6
6
1
9
PE
R
M
I
T
J
U
R
I
S
D
I
C
T
I
O
N
:
CI
T
Y
O
F
F
A
I
R
H
O
P
E
B.
F
.
E
.
:
1
2
'
'
A
.
C
L
.
R
W
FL
O
O
D
Z
O
N
E
:
"
X
"
MEAN ROOF HEIGHT: 17' -10''
CO
N
T
R
A
C
T
O
R
:
S
T
E
V
E
J
O
N
E
S
C
O
N
T
R
A
C
T
O
R
PR
O
J
E
C
T
:
R
E
M
O
D
E
L
S
I
N
G
L
E
F
A
M
I
L
Y
R
E
S
.
CL
I
E
N
T
:
L
U
C
I
N
D
A
&
C
H
I
P
C
H
A
P
P
E
L
L
E
LO
C
A
T
I
O
N
:
F
A
I
R
H
O
P
E
,
A
L
.
PH
Y
S
I
C
A
L
A
D
D
R
E
S
S
:
2
1
0
G
A
Y
F
E
R
C
T
.
Base Slab Elev: 24''' A.F.G. (Varies)
FINAL REVIEW - 12/04/25
PRELIM. REVIEW -09/16/25
PRELIM. REVIEW - 11/04/25
PRELIM. REVIEW - 10/07/25
PRELIM. REVIEW -09/17/25
c
2
0
2
5
C
O
P
Y
R
I
G
H
T
B
Y
K
.
A
.
T
.
D
e
s
i
g
n
s
I
n
c
.
T
h
e
s
e
d
r
a
w
i
n
g
s
a
r
e
N
O
T
T
O
B
E
re
p
r
o
d
u
c
e
d
o
r
c
o
p
i
e
d
i
n
a
n
y
f
o
r
m
w
h
a
t
s
o
e
v
e
r
w
i
t
h
o
u
t
t
h
e
w
r
i
t
t
e
n
pe
r
m
i
s
s
i
o
n
o
f
K
.
A
.
T
.
D
e
s
i
g
n
s
I
n
c
.
-
A
N
Y
D
U
P
L
I
C
A
T
I
O
N
I
S
P
R
O
H
I
B
I
T
E
D
A
N
D
PU
N
I
S
H
A
B
L
E
U
N
D
E
R
F
E
D
E
R
A
L
L
A
W
.
T
h
e
p
u
r
c
h
a
s
e
r
h
a
s
t
h
e
r
i
g
h
t
t
o
O
N
E
US
E
f
o
r
p
e
r
m
i
t
t
i
n
g
p
u
r
p
o
s
e
s
,
a
n
y
f
u
t
u
r
e
u
s
e
o
f
t
h
e
p
l
a
n
,
i
d
e
a
s
,
e
l
e
v
a
t
i
o
n
s
,
co
n
t
e
n
t
s
,
o
r
c
h
a
n
g
e
s
t
o
d
e
s
i
g
n
a
r
e
t
h
e
p
r
o
p
e
r
t
y
o
f
K
.
A
.
T
.
D
e
s
i
g
n
s
I
n
c
.
AN
D
M
U
S
T
B
E
A
U
T
H
O
R
I
Z
E
D
B
Y
K
.
A
.
T
.
D
e
s
i
g
n
s
I
n
c
.
A
N
Y
U
N
A
T
H
O
R
I
Z
E
D
U
S
E
WI
L
L
B
E
P
U
N
I
S
H
A
B
L
E
U
N
D
E
R
F
E
D
E
R
A
L
C
O
P
Y
R
I
G
H
T
L
A
W
S
.
CO
N
V
E
N
T
I
O
N
A
L
F
R
A
M
E
D
R
O
O
F
PL
A
N
w
/
N
O
T
E
S
&
D
E
T
A
I
L
S
A 1.12A 1.12A 1.12A 1.12
CONV. ROOF
FRAMING PLAN -
SCALE 3/16'' = 1'-0''
RIGHT REAR FRAMING OVERVIEW
SCALE 1/8'' = 1'-0''
REAR FRAMING OVERVIEW
SCALE 1/8'' = 1'-0''ROADSIDE FRAMING OVERVIEW
SCALE 1/8'' = 1'-0''Page 31 of 63
D/W D/W
REF.
UP
DN
GFCI
GFCI
GFCI
GFCI
GFCI
GFCI
WP
GFCI
WP
GFCI
WP
DISC
DISC
IN CLG
DISC
GFCI
DISC
IN CLG
GFCI
IN CLG
DISC
GFCI
R
R
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
M
AFCI
AFCI
AFCI
AFCI
AFCI
TV
CD
CW
AFCI
4
4
F
AFCI
AFCI
GFCI
3
F 4
4
AFCI
AFCI
AFCI
GFCIGFCI
AFCI AFCI AFCI
3
AFCI
AFCI
AFCI
G
DWDWGD
GFCI
GFCI GFCI GFCI
AFCIAFCI
AFCIAFCIAFCI4
3
AFCI
AFCI
GFCI
WP
AFCI
4
AFCI F DM
3
F 3AFCI
GFCI
AFCI AFCI
AFCI
AFCI AFCI 3
R RAFCI AFCIAFCI
AFCI
AFCI
TV
AFCI
AFCI
AFCI
AFCI
AFCI
AFCI
AFCI
AFCI
AFCI
AFCI
AFCI
AFCI
AFCI
H
CT
WO
WO
AFCI
AFCI
AFCI
AFCI
AFCI
AFCI
3 GFCI
WPFF
AFCIAFCI
GFCI
WP
AFCI
AFCI
AFCI
AFCIAFCI
AFCI AFCI F 3
M
AFCI AFCI F 3
AFCI
4
AFCI
AFCI
AFCI
AFCI
G
G
4
AFCI
AFCI
AFCI
AFCI
AFCI
AFCI
AFCI
GFCI
WP
TV
TV
AFCI
F
AFCI
AFCI
AFCI
DM
AFCI3
AFCI3
AFCI
DM
DB
4
AFCI
DM
DMAFCI
AFCIAFCI FDM
AFCI
TV
AFCI
AFCI
AFCI
TV
3
GFCI
WP
GFCI
WP
TV
AFCI AFCIAFCI AFCIAFCI
FP
GFCI
WP
AFCI
R
AFCI
36
'
'
H
I
D
D
E
N
CA
B
AC
C
E
S
S
BUTLERS PANTRY
66
'
'
V
A
N
I
T
Y
SH
W
R
S
E
A
T
36
'
'
T
A
L
L
CA
B
36
'
'
T
A
L
L
CA
B
FO
L
D
I
N
G
A
R
E
A
HA
N
G
I
N
G
CL
O
T
H
E
S
A
R
E
A
UP
P
E
R
C
A
B
S
30'' x 60'' ISLAND DRESSER W/ ELEC
STYLE OWNERS CHOICE
W
D
20'' EXTENDED BAR TOP
w/ SUPPORTS
db
l
w
a
l
l
ov
e
n
s
ZERO ENTRY
@ SHOWER
24
'
'
S
I
N
K
MI
C
R
O
BAR SINK
DRs SLIDE
BACK IN SIDES
OF CAB
STATIONARY
STAIR BY
LIFT UP INC.
SEE BUILDER
FOR SPECS
60
'
'
F
R
I
G
/
F
R
E
E
Z
E
R
BU
I
L
T
I
N
COF
FEE
BAR IC
E
36
'
'
G
A
S
C
T
.
MI
R
R
O
R
drop zone bench seat
temp gls
27
'
'
T
A
L
L
LI
N
C
A
B
TI
L
E
S
H
O
W
E
R
S
E
A
T
48'' SINK BASE
72'' X 36'' FREE
STANDING TUB
44
'
'
M
K
UP
V
A
N
I
T
Y
t
r
a
s
h
dr
a
w
e
r
t
r
a
s
h
dr
a
w
e
r
LANDING
8'-0'' 'VANITY
24'' DRW
STK
MICRO
UPPER WINE CAB
12'' EXTENDED BAR TOP
PLUG FOR
ELEC CAR
CHARGER
re
l
o
c
a
t
e
d
ga
s
m
e
t
e
r
re
l
o
c
a
t
e
d
El
e
c
m
e
t
e
r
LO
W
E
R
C
A
B
-
O
P
E
N
FO
R
L
D
R
Y
B
S
K
T
27
'
'
T
A
L
L
LI
N
C
A
B
24'' DRW
STK
24'' DRW
STK
48'' SINK BASE
8'-0'' 'VANITY
24'' DRW
STK
EL
E
C
/
G
A
S
VE
N
T
L
E
S
S
F
P
AIR
COMPRESSOR
TA
L
L
C
A
B
2x2 WALL SUR
FRAMED IN
REFRIG. SIDES
16
'
'
S
H
E
L
V
I
N
G
16'' SHELVING
temp gls RAIN
HD
STAIRS REMOVED
FOR CLARITY
BATH FIXTURES TO
REMAIN AS IS
BATH FIXTURES TO
REMAIN AS IS
16
'
'
d
U
P
P
E
R
C
A
B
S
HO
O
D
V
T
R
36''d BASE CAB
LANDING
chandiler
AFCI
AFCI
SW FOR
LAMPS
SW FOR
LAMPS
MB
C-1
MB
C-2
30'' TALL
CAB
HA
N
G
I
N
G
R
O
D
UC
L
T
LR
C-1
LR
C-2
1/2 TEMP GLS
ABOVE K.W.
MB
C-3
A/C
A/C
H2
0
H2
0
ST
A
I
R
L
T
S
S
W
@
B
O
T
H
E
N
D
S
LOCATE
CHAND POS w/
OWNERS
DROP PENDANTS
DROP PENDANTS
UC
L
T
UC
L
T
UCLT
UC
L
T
UCLT
ELECTIRCAL PANELS
P
2
ISL
VT
P
C-3
P
C-1
P
C-2
HL
C-1
PB
C-1
30'' VANITY
K
C-1
K
C-2
CUSTOM
BUILT INs -
SEE
OWNERS
CUSTOM
BUILT INs -
SEE
OWNERS
ER
C-1
K
C-3
K
C-4
HB
HB
HB
HB
HB
HB
HB
HB
CM CM
CM
CM
CM
DN
REF.
UP
GFCI
RR
SD
SD
SD
SD
AFCI
AFCI
AFCI
AFCI
AFCI
AFCI AFCIAFCI
AFCI
AFCI
AFCI
AFCI
AFCI
AFCI
F
R AFCI
3
AFCI 3
AFCI 3
AFCI
AFCI
AFCI
AFCI
AFCI
GFCI
AFCI
AFCI
GFCI GFCI
AFCI
AFCI
FFAFCIAFCIAFCI3
WP
AFCI
AFCI
AFCI
BEDROOM #4
GUEST BATH
8' CLG
CHIPS OFFICE
LOFT / MUSIC
STUDIO AREA
w/ DBL STEP TRAY
CLG TO 9' CTR.
CLOSET
8'
1
'
'
W
A
L
L
H
G
T
A
T
T
H
I
S
S
I
D
E
8'
1
'
'
W
A
L
L
H
G
T
A
T
T
H
I
S
A
R
E
A
LI
N
E
O
F
8
'
V
A
L
L
E
Y
A
R
E
A
LI
N
E
O
F
8
'
C
E
I
L
I
N
G
LI
N
E
O
F
8
'
C
E
I
L
I
N
G
8' BASE HGT
8'
B
A
S
E
H
G
T
8' BASE HGT
8'
B
A
S
E
H
G
T
8' - CLG HGT
8' - CLG HGT
LINE OF 8' VALLY AREA
LINE OF 8'
VALLY AREA
CE
I
L
I
N
G
S
L
O
P
E
S
WI
T
H
S
T
A
I
R
S
LIN
CAB
30'' SINK BASE
3x5 TILE SHWR
18
'
'
d
e
p
t
h
f
u
t
u
r
e
en
t
e
r
t
a
i
n
m
e
n
t
ce
n
t
e
r
15''
DR
STK
15''
DR
STK
60'' VANITY
36
'
'
K
.
W
.
S
U
P
@
E
X
T
.
B
R
G
.
36
'
'
K
.
W
.
S
U
P
@
E
X
T
.
B
R
G
.
60
'
'
K
.
W
.
S
U
P
@
I
N
T
.
B
R
G
.
60
'
'
K
.
W
.
S
U
P
@
I
N
T
.
B
R
G
.
SLOPE TO 8'SLOPE TO 8'
SLOPE TO 8'SLOPE TO 8'
SLOPE
SLOPE
8'
1
'
'
W
A
L
L
H
G
T
A
T
T
H
I
S
A
R
E
A
8' CEILING
LOFT AREA
ELEC PANEL
2F
C-1
CM
C7/IT
GFCI GFCI
WP
R
VTR
SD
R
43 DM WPFP
DISC
DB TG
GD
= PADDLE FAN w/ LIGHT KIT
= SMOKE DETECTOR
CARBON MONOXIDE
= PHONE/INTERNET
JACK
= RECESSED CAN LIGHT
SOFFIT LIGHT & PORCH CANS
= CEILING MOUNTED
LIGHT FIXTURE
= EXHAUST FAN w/
HEAT LAMP-LT
= 220 V RECEPTICAL
= SWITCHES
= 110 V RECEPTICAL
NOTE: QUANITIES AND LOCATIONS
OF ALL T.V. & TELEPHONE JACKS
TO BE DETERMINED BY OWNERS
ELECTRICAL LEGEND
= ELEC. PANEL BOX
= T.V. JACKS
= EXTERIOR FLOOD LT
w/ SWITCH
= 110 V GFCI REC.
PROVIDE
SEPARATE
SWITCHES
FAN/LIGHT
= CEILING LIGHT/DROP
PENDENT
= WALL LIGHT
BATH RM. SINK
TV
IT
CLOSET BACK
LIGHTING48''24''
WALL SCONCE
EXT. COACH LT.
ELEC PANEL
TV
CM
LED
=UNDER CAB LIGHTING
= SPECIAL ITEMS
= CHANDELIER
NOTE ALL ELECTRICAL ITEMS INSTALLED IN THIS STRUCTURE MUST COMPLY WITH NEC 2017 CODES or
LATEST ADOPTED LOCAL ELECTRICAL CODE STANDARDS FOR WHICH IT IS PERMITTED IRC-2018.
============================================================
NOTE: OUTLETS IN KITCHEN/BATH WET AREAS SHALL BE GFCI IN ACCORDANCE WITH CODE, ALL ROOMS
WILL BE SUPPLIED WITH SMOKE DETECTORS HARD WIRE w/ BATTERY BACK UP. CARBON MONOXIDE
DETECTORS INSTALLED IN AREAS WHERE GAS FIRE PLACES ARE WITHIN THE INTERIOR OF A RESIDENCE OR
GAS APPLIANCES ARE PRESENT. ALL EXTERIOR LIGHTING TO BE CHOSEN BY OWNERS w/ ELECTRICIAL.
CONTRACTOR TO VERIFY PLACEMENT OF LIGHTING IN RELATION TO A NO CONFLICT ZONE FOR ADJACENT
HOME OWNERS, WILDLIFE, OR HABITATS.
=============================================================
NOTE: ALL ELECTRICAL T.V. / COMPUTER- DSL / & PHONE OUTLETS IN RESIDENCE TO BE INSTALLED IN
ACCORDANCE NEC CODE REQ - VERIFY LOCATIONS WITH OWNERS PRIOR TO INSTALLATION. (LOCATE FLOOR
OUTLETS WITH OWNERS IF REQ.) OWNER'S MAY CHANGE LIGHTING TYPES, (INT. OR EXT.) ALL LIGHTING
SYMBOLS USED ON PLANS ARE GENERAL USE ITEMS AND UNDER NO CIRCUMSTANCE PROMOTES THE USE
OF SPECIFIC ITEMS. OWNER HAS COMPLETE CHOICE OF INSTALLED ELECTRICAL ITEMS.
PRINT DATES
FINAL PRINT - 12/09/25
DESIGN DRAWN BY
Kirk A. ThomasKirk A. ThomasKirk A. ThomasKirk A. Thomas
To
t
h
e
b
e
s
t
o
f
m
y
k
n
o
w
l
e
d
g
e
t
h
e
s
e
p
l
a
n
s
a
r
e
d
r
a
w
n
t
o
c
o
m
p
l
y
w
i
t
h
t
h
e
c
o
d
e
r
e
q
u
i
r
e
m
e
n
t
s
f
o
r
th
e
i
r
i
n
t
e
n
d
e
d
u
s
e
b
y
o
w
n
e
r
'
s
a
n
d
/
o
r
b
u
i
l
d
e
r
'
s
s
p
e
c
if
i
c
a
t
i
o
n
s
,
a
n
y
c
h
a
n
g
e
s
m
a
d
e
o
n
o
r
t
o
t
h
e
m
af
t
e
r
p
r
i
n
t
s
a
r
e
s
e
a
l
e
d
w
i
l
l
b
e
d
o
n
e
a
t
t
h
e
o
w
n
e
r
'
s
a
n
d
/
o
r
b
u
i
l
d
e
r
'
s
e
x
p
e
n
c
e
a
n
d
r
e
s
p
o
n
s
i
b
i
l
i
t
y
.
Th
e
c
o
n
t
r
a
c
t
o
r
s
h
a
l
l
v
e
r
i
f
y
a
l
l
d
i
m
e
n
s
i
o
n
s
a
n
d
e
n
c
l
os
e
d
d
e
t
a
i
l
d
r
a
w
i
n
g
s
.
R
e
f
e
r
I
n
s
t
a
l
l
a
t
i
o
n
o
f
a
l
l
ma
t
e
r
i
a
l
s
t
o
m
a
n
u
f
a
c
t
u
r
e
s
a
n
d
c
o
d
e
r
e
q
u
i
r
m
e
n
t
s
f
o
r
ea
c
h
i
t
e
m
s
a
t
t
a
c
h
m
e
n
t
t
o
t
h
e
s
t
r
u
c
t
u
r
e
re
q
u
a
r
d
l
e
s
s
o
f
d
e
t
a
i
l
s
h
o
w
n
.
D
e
t
a
i
l
s
a
r
e
n
o
t
s
p
e
c
i
fi
c
t
o
s
t
r
u
c
t
u
r
e
d
r
a
w
n
,
d
e
t
a
i
l
s
a
r
e
d
r
a
w
n
a
s
pe
r
s
p
e
c
t
i
v
e
c
u
t
a
w
a
y
v
i
e
w
s
a
n
d
i
n
n
o
w
a
y
s
h
o
w
m
a
t
e
r
i
al
i
t
e
m
s
a
s
f
i
n
i
s
h
e
d
i
n
s
t
a
l
l
e
d
re
p
r
e
s
e
n
t
a
t
i
o
n
.
k
.
a
.
t
.
D
e
s
i
g
n
s
I
n
c
.
i
s
n
o
t
l
i
a
b
l
e
f
or
e
r
r
o
r
s
b
a
s
e
d
u
p
o
n
p
e
r
s
o
n
a
l
i
n
t
e
r
p
r
e
t
a
t
i
o
n
of
a
n
y
d
e
t
a
i
l
,
t
e
x
t
i
t
e
m
,
o
r
s
y
m
b
o
l
u
s
e
d
i
n
t
h
e
c
r
e
at
i
o
n
o
f
t
h
e
s
e
d
o
c
u
m
e
n
t
s
.
W
h
i
l
e
e
v
e
r
y
e
f
f
o
r
t
ha
s
b
e
e
n
m
a
d
e
i
n
t
h
e
p
r
e
p
a
r
a
t
i
o
n
o
f
t
h
i
s
p
l
a
n
t
o
a
v
oi
d
m
i
s
t
a
k
e
s
,
t
h
e
m
a
k
e
r
c
a
n
n
o
t
g
u
a
r
a
n
t
e
e
ag
a
i
n
s
t
h
u
m
a
n
e
r
r
o
r
.
T
h
e
L
i
c
.
C
o
n
t
r
a
c
t
o
r
/
O
w
n
e
r
s
o
f
th
e
p
r
o
j
e
c
t
m
u
s
t
c
h
e
c
k
a
l
l
d
i
m
e
n
s
i
o
n
s
a
n
d
de
t
a
i
l
s
p
r
i
o
r
t
o
c
o
n
s
t
r
u
c
t
i
o
n
a
n
d
b
e
s
o
l
e
l
y
r
e
s
p
o
n
s
ib
l
e
u
p
o
n
i
s
s
u
e
d
p
e
r
m
i
t
.
A
l
l
i
n
f
o
r
m
a
t
i
o
n
co
n
t
a
i
n
e
d
w
i
t
h
i
n
t
h
e
s
e
p
l
a
n
s
i
s
s
u
b
j
e
c
t
t
o
c
h
a
n
g
e
b
as
e
o
n
c
o
d
e
r
e
q
u
i
r
e
m
e
n
t
s
a
n
d
p
e
r
m
i
t
t
i
n
g
ju
r
i
s
d
i
c
t
i
o
n
I
n
t
e
r
p
r
e
t
a
t
i
o
n
.
Page #Page #Page #Page #
PL
A
N
S
C
A
L
E
:
BA
S
E
@
1
/
4
"
=
1
'
-
0
'
'
U.
O
.
N
.
S
C
A
L
E
M
A
Y
V
A
R
Y
P
E
R
P
L
A
N
OR
P
E
R
D
E
T
A
I
L
(
N
O
T
S
P
E
C
I
F
I
C
)
Building Code: IRC2018
Design Wind Speed: 130 mph
ASD - ASCE 7-10
Design Wind Speed: 160 MPH
Ultimate - ASCE 7-16
Req. Glazing & Door Design
Pressures (DP's) 50 psf
All Doors and Glazing Installed
shall be Impact Rated
Flood Zone: FIRM - X
Finish Floor Elevation:
Min. 36'' A.CL.RW.
Mean Roof Height:
I,
L
a
r
r
y
M
.
O
l
i
v
e
r
,
P
.
E
.
,
L
i
c
e
n
s
e
N
o
.
1
2
6
7
8
Ce
r
t
i
f
y
t
h
a
t
t
h
e
s
t
r
u
c
t
u
r
a
l
p
o
r
t
i
o
n
s
o
f
t
h
i
s
se
t
o
f
c
o
n
s
t
r
u
c
t
i
o
n
d
o
c
u
m
e
n
t
s
h
a
v
e
b
e
e
n
re
v
i
e
w
e
d
u
n
d
e
r
m
y
r
e
s
p
o
n
s
i
b
l
e
c
h
a
r
g
e
,
de
s
i
n
a
t
e
d
b
y
d
e
s
i
g
n
,
t
o
c
o
m
p
l
y
w
i
t
h
t
h
e
en
g
i
n
e
e
r
i
n
g
r
e
q
u
i
r
e
m
e
n
t
s
o
f
t
h
e
In
t
e
r
n
a
t
i
o
n
a
l
R
e
s
i
d
e
n
t
i
a
l
B
u
i
l
d
i
n
g
C
o
d
e
,
20
1
8
L
a
t
e
s
t
E
d
i
t
i
o
n
@
1
3
0
/
1
6
0
-
m
p
h
3
se
c
g
u
s
t
w
i
n
d
l
o
a
d
r
a
t
i
n
g
.
La
r
r
y
M
.
O
l
i
v
e
r
E
n
t
e
r
p
r
i
s
e
s
I
n
c
.
72
2
8
O
a
k
b
r
i
a
r
D
r
i
v
e
S
o
u
t
h
Mo
b
i
l
e
,
A
L
.
3
6
6
1
9
PE
R
M
I
T
J
U
R
I
S
D
I
C
T
I
O
N
:
CI
T
Y
O
F
F
A
I
R
H
O
P
E
B.
F
.
E
.
:
1
2
'
'
A
.
C
L
.
R
W
FL
O
O
D
Z
O
N
E
:
"
X
"
17' - 10''
CO
N
T
R
A
C
T
O
R
:
S
T
E
V
E
J
O
N
E
S
C
O
N
T
R
A
C
T
O
R
PR
O
J
E
C
T
:
R
E
M
O
D
E
L
S
I
N
G
L
E
F
A
M
I
L
Y
R
E
S
.
CL
I
E
N
T
:
L
U
C
I
N
D
A
&
C
H
I
P
C
H
A
P
P
E
L
L
E
LO
C
A
T
I
O
N
:
F
A
I
R
H
O
P
E
,
A
L
.
PH
Y
S
I
C
A
L
A
D
D
R
E
S
S
:
2
1
0
G
A
Y
F
E
R
C
T
.
Base Slab Elev: 24''' A.F.G. (Varies)
FINAL REVIEW - 12/04/25
PRELIM. REVIEW -09/16/25
PRELIM. REVIEW - 11/04/25
PRELIM. REVIEW - 10/07/25
PRELIM. REVIEW -09/17/25
c
2
0
2
5
C
O
P
Y
R
I
G
H
T
B
Y
K
.
A
.
T
.
D
e
s
i
g
n
s
I
n
c
.
T
h
e
s
e
d
r
a
w
i
ng
s
a
r
e
N
O
T
T
O
B
E
re
p
r
o
d
u
c
e
d
o
r
c
o
p
i
e
d
i
n
a
n
y
f
o
r
m
w
h
a
t
s
o
e
v
e
r
w
i
t
h
o
u
t
t
h
e
w
r
i
t
t
e
n
pe
r
m
i
s
s
i
o
n
o
f
K
.
A
.
T
.
D
e
s
i
g
n
s
I
n
c
.
-
A
N
Y
D
U
P
L
I
C
A
T
I
O
N
I
S
P
R
O
H
I
B
I
T
E
D
A
N
D
PU
N
I
S
H
A
B
L
E
U
N
D
E
R
F
E
D
E
R
A
L
L
A
W
.
T
h
e
p
u
r
c
h
a
s
e
r
h
a
s
t
h
e
ri
g
h
t
t
o
O
N
E
US
E
f
o
r
p
e
r
m
i
t
t
i
n
g
p
u
r
p
o
s
e
s
,
a
n
y
f
u
t
u
r
e
u
s
e
o
f
t
h
e
pl
a
n
,
i
d
e
a
s
,
e
l
e
v
a
t
i
o
n
s
,
co
n
t
e
n
t
s
,
o
r
c
h
a
n
g
e
s
t
o
d
e
s
i
g
n
a
r
e
t
h
e
p
r
o
p
e
r
t
y
o
f
K
.
A
.
T
.
D
e
s
i
g
n
s
I
n
c
.
AN
D
M
U
S
T
B
E
A
U
T
H
O
R
I
Z
E
D
B
Y
K
.
A
.
T
.
D
e
s
i
g
n
s
I
n
c
.
A
N
Y
U
NA
T
H
O
R
I
Z
E
D
U
S
E
WI
L
L
B
E
P
U
N
I
S
H
A
B
L
E
U
N
D
E
R
F
E
D
E
R
A
L
C
O
P
Y
R
I
G
H
T
L
A
W
S
.
SECOND FLOOR ELECTRICAL &
LIGHTING PLAN - SCALE 1/4'' = 1'-0''
FIRST FLOOR ELECTRICAL & LIGHTING PLAN - SCALE 1/4'' = 1'-0''
1S
T
&
2
N
D
F
L
O
O
R
P
L
A
N
S
w
/
EL
E
C
T
R
I
C
A
L
F
I
X
T
U
R
E
S
&
L
I
G
H
T
I
N
G
LO
C
A
T
I
O
N
S
w
/
E
L
E
C
L
E
G
E
N
D
Note: Electrician to prewire all ceiling fans for remote control use. If
switch is needed please provide- Additional switch not shown on
plans. U.O.N. ELECTRICAL CONTRACTOR TO DO WALK THRU w/
OWNERS PRIOR TO INSTALLATION OF ELECTRICAL MATERIALS,
VERIFY LOC OF ALL SWITCHES, TV, PH, OUTLET LOC.
A 1.13A 1.13A 1.13A 1.13
Page 32 of 63
2018 ENERGY - HVAC - TESTING, LIGHTING & INSULATION REQ.:
===================================
R402.4.1.2 (N1102.4.1.2) Testing (Mandatory).
=====================================
The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding 5 air changes per hour. Testing shall be
conducted with a blower door at a pressure of 0.2 inches w.g. (50 Pascals). Testing shall be performed at any time after creation of all
penetrations of the building thermal envelope.
During Testing:
1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weather stripping or other
infiltration control measures;
2. Dampers including exhaust, intake, make up air, backdraft and flue dampers shall be closed, but not sealed beyond intended infiltration
control measures;
3. Interior doors, if installed at the time of the test, shall be open;
4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed;
5. Heating and cooling systems, if installed at the time of the test, shall be turned off and shall be fully open.
6. Supply and return registers, if installed at the time of the test, shall be fully open.
7. HVAC Contractor will be required to provide dampers where Outdoor units are installed and out door air is to be provided to the structure.
Piling Homes: Units are to be placed on a platform above the min 10'-0'' parking area and not to protrude over the min property set back
requirements.
8. Blower door test is required prior to final inspection.
R402.4.5 (N1102.4.5) Recessed lighting.
================================
Recessed luminaries installed in the building thermal envelope shall be installed sealed to limit air leakage between conditioned and
unconditioned spaces. All recessed luminaries shall be IC- rated and labeled as having an air leakage rate not more than 2.0 cfm (0.944 L/s)
when tested in accordance with ASTM E 283 at a 1.57 psf (75 Pa) pressure differential. All recessed luminaries shall be sealed with a gasket or
caulk between the housing and the interior wall or ceiling covering.
R404.1 (N1104.1) Lighting Equipment (Mandatory)
=======================================
Not less than 75 percent of the lamps in permanently installed lighting fixtures at the time of inspection shall be high-efficacy lamps or not
less that 75 percent of the permanently installed lighting fixtures shall contain only high efficacy lamps.
Spray Foam Insulation v/s Batt Insulation:
=================================
Spray foam is an optional use of materials - Plans show a use of Batts or Spray Foam. If Spray foam is used a barrier of 1/2" Gypsum board
will be installed where spray foam is to be used @ interior wall separations. All new exterior walls shall have spray foam insulation along with
Roof rafter areas in attic. Optional batts may be used in between floor truss to lower ceiling separations.
ELECTRICAL NOTES
==================
1. ALL UTILITIES ARE REQUIRED TO BE INSTALLED UNDEGROUND. ALL RACEWAYS UNDERGROUND SHALL BE #14 AWG, EXCLUDING CONTROL
WIRING. U.O.N. ALL CONDUCTORS SHALL BE COPPER WITH IHW INSULATION (ROMEX IS ACPT. WHERE CODE ALLOWS.)
2. SEWER CONNECTION AND GRINDER PUMP INSTALLATION MUST BE COMPLETED, INSPECTED AND RELEASED BY THE SEWER DEPT PRIOR TO
CONNECTION OF POWER TO STRUCTURE.
3. EMERGENCY EQUIPMENT GFCI OUTLET FOR DISHWASHER TO GO IN INTERIOR CABINET AT SINK.
4. ALL ELECTRICAL WORK SHALL BE IN STRICT ACCORDANCE WITH THE MOST RECENTLY ADOPTED NATIONAL ELECTRICAL CODE AND ALL
LOCAL CODES.
5.. PROVIDE INSULATED CEILING KITS FOR RECESSED LIGHTS AT ALL LOCATIONS WHERE INSULATION IS USED. PROVIDE FIXTURES SUITABLE
FOR DAMP LOCATIONS AT EXTERIOR LOCATIONS. ALL EXTERIOR FIXTURES SHALL HAVE LENSES.
6. ALL OUTLETS INSTALLED IN BEDROOMS TO BE PROTECTED BY A COMBINATION TYPE OR BRANCH /FEEDER TYPE ARC-FAULT CIRCUIT
INTERUPTER TO PROVIDE PROTECTION OF THE ENTIRE BRANCH CIRCUIT.
7. SEE OWNER FOR ALL FIXTURE TYPES AND STYLES:
COORDINATE ALL SWITCH LOCATIONS AND REQUIREMENTS WITH OWNER PRIOR TO CONSTRUCTION
COORDINATE LOCATION OF ANY SECURITY SYSTEMS WITH OWNER.
COORDINATE LOCATION OF ALL PREWIRING (CATV, PHONE, SURROUND SOUND, INTERCOM ETC... WITH OWNER.
8. RECEPTICALES WITHIN 6' OF ALL SINKS SHALL BE GFCI PROTECTED.
9. EXTERIOR RECEPTICALES & LIGHTING FIXTURES SHALL BE GFCI PROTECTED IN WEATHER PROOF ENCLOSURES.
10. SMOKE DETECTOR SHALL BE HARD WIRED WITH BATTERY BACKUP AND INSTALLED AT LOCATIONS AS REQUIRED BY CODE. CARBON
MONOXIDE DET. TO BE INSTALLED HARD WIRED TO MAIN PANEL w/ BATTERY BACK UP IN LOCATIONS AS REQ. BY CODE.
11. PREWIRE FOR SEPARATE SWITCHES TO CEILING FAN AND LIGHT .
12. CLOTHES DRYER EXHAUST IS LIMITED TO A DEVELOPED LENGTH OF 35' AND MUST TERMINATE TO THE OUTDOORS.
13. ALL RECEPTICALS SHALL BE LISTED TAMPER RESISTANT UNLESS THE EXCEPTED BY E4002.14.
14. ALL 120V BRANCH CIRCUITS SHALL BE PROTECTED BY A COMBINATION TYPE ARC FAULT CITCUIT INTERRUPTER UNLESS EXCEPTED BY
E3902.13
15. A MINIMUM OF TWO GROUNDING ELECTRODES ARE REQUIRED UNLESS THE RESISTANCE IS VERIFIED AS BEING TWENTY FIVE (25) OHMS OR
LESS.
16. ALL DIRECTLY EXPOSED METAL CONNECTORS MUST BE STAINLESS STEEL. (REQ. FOR ALL HIGH CORROSIVE ZONES).
17. ELECTRICIAN WILL LOCATE ELECTRICAL PANELS AND WATER HEATERS PER IRC2018 REQUIREMENTS.
VERIFY LOCATION DURING 4-WAY INSPECTION. ELECTRICAL CONTRACTOR TO SIZE AND VERIFY ALL SERVICES TO UNITS AND MAIN SERVICES.
18. PER E3906.1 - ONE RECEPTICAL SHALL BE PLACED AT EACH LAVATORY BASIN AS GFCI TYPE.
19. BATHROOMS: EXHAUST FANS SALL BE INSTALLED IN ALL TOILET AREA/ AND TUB/SHOWER AREAS.
20. KITCHEN: SPACING FOR COUNTERTOP RECEPTICALS PER SECTION E 3901.4.1 (NO POINT ALONG WALL MORE THAN 24'' TO A RECEPTICAL,
iSLAND AND PENINSULAR COUNTERTOPS 24'' OR GREATER.
21. CONTRACTOR WILL VERIFY LOCATION OF T.V., PHONE, & CAT 7 INTERNET JACKS WITH ELECTRICIAN.
22. H.V.A.C. CONTRACTOR WILL VERIFY & LOCATE DIFFUSERS & RETURNS PER CODE REQ. PROVIDE CERTIFICATION ON DUCT WORK LEAKAGE
TESTING. PROVIDE CERTIFICATION ON BLOWER DOOR TESTING.
23. INTERIOR HVAC RETURN UNIT TO BE INSTALLED PER MANUFACTURER IN AREA RECOMENDED BY HVAC CONTRACTOR - PROVIDE DRAIN TO
EXT. THROUGH SOFFIT AREA IF INSTALLED IN ATTIC AREAS.
2018 ENERGY CODE COMPLIANCE REQ.
======================================
1. At the time of rough-in inspection Peel and Seal aluminum backed tape or other approved material shall be applied to
all edges of all windows to prevent air exchange.
a. All holes on interior and exterior wall top plates shall be sealed.
b. All holes and spaces around plumbing pipes, electrical, and mechanical penetrating interior or exterior wall top
plates shall be sealed.
2. The contractor or owner contractor shall be responsible for compliance of items a,b,& c below.
a. Doors shall be caulked or latex foamed from from the inside between frame and rough opening.
b. All holes interior and exterior wall top plates shall be sealed with caulking or expandable foam.
c. Space around plumbing pipes penetrating interior or exterior wall top plates shall be sealed with caulking or
expandable foam.
3. Builder to comply with 2018 Energy compliance requirements, per submitted documents along with plans see owners
for copy. Additional items included in submitted documents will be met by builder during construction of the residence.
======================================================================================
Building cavities shall not be used as ducts or plenums.
Programmable thermostat shall be used where the primary system is a forced-air furnace.
All supply and return ducts not completely inside the building thermal envelope shall be insulated to a minimum of R -
6.
Mechanical system piping (Freon line) capable of carrying fluids above 105ºF or below 55ºF shall be insulated to a
minimum of R - 6. Piping insulation shall be protected from damage including environmental damage.
A minimum of 75% of lamps in permanently installed lights shall be of high efficacy.
All Windows must have a DPI factor of .50 min. and a SHGC Range from 0 -1 and a U Factor Range of 0.20 - 1.20
All Doors must maintain a min. SHGC Range from 0 - 1 and a U Factor Range of 0.00 - 2.00
Attic insulation must be a minimum of R-38.,Wall insulation must be a minimum of R-15., Floor insulation must be a
minimum of R-19.
All holes on Interior and Exterior wall top plates shall be sealed.
All holes and spaces around plumbing pipes, electrical, and mechanical penetrating interior or exterior wall top plates
shall be sealed.
Dwelling units shall be tested and verified as having an air leakage rate of not exceeding 5 ACH when conducted with a
blower door at a pressure of 0.2 inches w.g. or by visual inspection when the items listed above and in Table
N1102.4.1.1 are met and field verified.
======================================================================================
INSULATION REQ:
***********************
1. All 6'' exterior walls must achieve a min. R-21 Insuation between cavitys of exterior wall studs where located. or a
min R-19 must be achieved with the use of spray foam, fiberglass, blown, or wool batt type insulation installed.
1.a All 4" interior walls must achieve a minimum R-15 Insuation between cavitys of exterior wall studs where located.
or a min R-15 must be achieved with the use of spray foam, fiberglass, blown, or wool batt type insulation installed.
2. All attic ceiling areas must achieve a min. R-38 or better foam insuation between cavitys of exterior wall studs
where located. or a min R-38 or better must be achieved with the use of fiberglass, blown, wool batt type insulation
installed.
3. All vaulted ceilings must achieve a min. R-38 Foam, or blanket insulation-Allow for1/2" min. airspace between
underside of sheathing to insulation face, batts must be installed foil down to warm side.
4. All floors must achieve a min. R-19 or better, foam, batts, or foil back insulation between joists. If applicable to plan
design.
5. Perimeter concrete walls to be protected with a min. R-6 ridged fiberboard insulation from top of concrete wall to not
less than 24" below grade.
6. All exterior doors other than main entry doors, must be insulated to a U= value of 0.20.
The main entry door U= value may not exceed 0.54.
7. Heating ducts to be insulated with a min. R-8.
8. Windows shall be required to have a U=0.25 value and U=0.50 for skylights.
9. Flat ceiling shall meet the min. R-38 rating. where applicable within conditiond air space.
PLUMBING NOTES:
================
1. On Demand Water heater - Shall be Either Electric/gas min 50 gal capacity with 4.5 kW. Hot water transfer piping shall be insulated to
a min. R-8.
2. Water heater #1 to be installed outside of each left & right elevation walls as shown. Water heater shall be provided with an
approved, self closing presure relief valve. Discharge from the relief valve shall be indirectly connected to the drainage system. &
attached to wall with strapping as per IRC- 2018 mechanical code req
3. Cold water service to residential structure shall be a 1'' line with a 3/4'' line to each unit.
4. Plumber to install exterior hose bibbs in locations designated per owners request. Each HB shall be 1/2'' non-freeze units.
5. Gas piping systems shall comply with the IRC 2018 applical gas codes.
6. All installation and materials shall comply with applicable codes for the IRC 2018 Pluming code and or Local req. The contractor
responsible for construction shall call in for all 4- way inspections. Top out plumbing inspection shall be performed with Electrical,
HVAC, and Framing inspection.
7. Shower water valves shall be balanced presure ballanced valves with maximum water temp of 110 degrees.
8. All bath tubs and showers shall be conntected to the drain waste and vent system at time of top out inspection.
Exception: Whirlpool and Garden tubs may be installed after top out inspection. The trap servicing the whirlpool and garden tub shall
be installed at the time of inspection. Please refer all installation of plumbing fixtures to your Plumbing Contractor, Plumbing plans are
not prepared by this firm. Refer all installation requirements to the IBC 2018 Plumbing & Gas Codes latest adopted edition or Local
code req.
9 Where quick closing automatic valves (dishwasher/washing machines) are connected to the water system, hammer arresters are
required.
10. Water shut off valves shall be installed at each fixture, sillcock,or appliance.
11. Provide a thermal expansion tank on the cold water line with a pressure reducing valve (install per manufactures recomendations)
12. Cleanouts shall be provided in horizontal drains and building sewers at max. 100 foot apart and changes of direction greater than 45
degrees.
13. provide a double backflow device on the water service to each unit.
14. Plumbing contractor shall provide trap seal prime valves for all floor drains and hub drains.
Pex supply piping shall be inspected at working water pressure, minimum pressure shall be 50 lbs.
15. Potable water supply at working pressure shall be connected to supply piping at time of inspection.
IRC 2018 - PLUMBING NOTES
==========================
1. Pex supply piping shall be inspected at working water pressure, minimum pressure shall be 50 lbs.
2. Potable water supply at working pressure shall be connected to supply piping at time of inspection.
3. Top out plumbing inspection shall be performed with Electrical, HVAC, and Framing inspection.
4. The contractor responsible for construction shall call in for all 4- way inspections.
5. All bath tubs and showers shall be conntected to the drain waste and vent system at time of top out inspection.
Exception: Whirlpool and Garden tubs may be installed after top out inspection. The trap servicing the whirlpool and garden tub shall
be installed at the time of inspection.
ENERGY EFFICIENCY REQUIREMENTS
=================================
1. ALL EXTERIOR JOINTS & CRACKS ARE TO BE CAULKED, GASKETED, WEATHER STRIPPED OR OTHERWISE SEALED.
2. ALL OPENINGS IN THE AIR BARRIER BETWEEN CONDITIONED & UNCONDITIONED SPACE MUST BE SEALED, INCLUDING SEALING
BETWEEN WINDOWS/DOORS & THIER ROUGH OPENINGS, THE CONNECTION BETWEEN WALLS & SLABS & THE CONNECTION BETWEEN
WALLS & FLOOR OR ROOF SYSTEMS. ALL LIGHTING RECESSED INTO INSULATION SPACE SHALL BE TYPE IC WITH NO PENETRATIONS.
3. EXTERIOR WINDOWS & DOORS SHALL BE RATED TO ALLOW A PENETRATION OF A MAXIMUM 0.3 CFM/SF OF DOOR AREA. ALL
GLAZING IN EXTERIOR DOORS AND WINDOWS SHALL BE DOUBLE PANED, & ALL WINDOWS SHALL HAVE A MAXIMUM SOLAR HEAT GAIN
COEFFICIENT (SHGC) OF 0.3. EXTERIOR DOORS & WINDOWS SHALL COMPLY WITH THE CRITERIA IN THE ENERGY CALCULATIONS FOR
THIS PROJECT WHICH ACCOMPANY THESE DRAWINGS, OR MAY BE COMPLETED BY OTHER AND SUBMITTED FOR APPROVAL.
4.EXHAUST FANS VENTED TO UNCONDITIONED SPACES SHALL HAVE DAMPERS, EXCEPT FOR COMBUSTION DEVISES WITH INTEGRAL
EXHAUST DUCTWORK. COMBUSTION SPACE & WATER HEATING SYSTEMS MUST BE PROVIDED WITH OUTSIDE COMBUSTION AIR,
EXCEPT FOR DIRECT- VENT APPLIANCES.
5. FOR WATER HEATERS, (IF SHOWN IN DRAWINGS) A CLEARLY MARKED BREAKER (FOR ELECTRICAL MODELS) SHALL BE PROVIDED.
OR A CLEARLY MARKED CUT OFF VALVE ( FOR GAS MODELS) SHALL BE PROVIDED.AN EXTERNAL OR BUILT IN HEAT TRAP IS
REQUIRED IN ALL WATER HEATERS. INSULATION IS REQUIRED ON HOT WATER PIPES FOR HOT WATER CIRCULATING SYSTEMS (
INCLUDING HEAT RECOVERY UNITS). SHOWER HEADS MUST HAVE FLOW RESTRICTORS THAT REDUCE THE FLOW TO A MAXIMUM OF 2.5
GAL PER MINUTE AT A PRESSURE OF 80 PSI.
6. ALL DUCTS, FITTINGS, MECHANICAL EQUIPMENT & PLENUM CHAMBERS SHALL BE MECHANICALLY ATTACHED, SEALED, INSULATED
& INSTALLED IN ACCORDANCE WITH THE 2024 IRC/ 2024 IMC OR 2018 IBC REQUIREMENTS.
7. INSULATION IN THE EXTERIOR ENVELOPE SHALL BE AS FOLLOWS:
ROOF: SHALL MEET A MIN OF R-38 RATING AS BATT TYPE OR CLOSED CELL SPRAY FOAM INSULATION.
EXTERIOR WALLS: 2X6 - MIN. (R-21) 2X4 MIN. ( R- 13)
EXPOSED FLOORS IF REFERENCED IN PLANS - ABOVE CONDITIONED @ MIN. (R-19) OR NON- CONDITIONED SPACES @ MIN. (R- 38).
SMOKE ALARMS & CARBON MONOXIDE DETECTORS - PURSUANT TO IRC - 2018 Section (R315 & R314.3)
=============================================
SMOKE ALARMS:NFPA72
SMOKE ALARM INSTALLATION AREAS SHALL BE:
A.) Single and multiple-station smoke alarms shall be installed in the following locations:
1. Each sleeping room
2. Outside of each sleeping area in the immediate vicinity of the bedrooms.
3. 3 ft horizontally from the door or openingof a bathroomwith a bathtub or shower.
4. One to be installed on each additional story of the dwelling, including habitable Attics, Basements & Cellars but not
including crawl spaces or any uninhabitable areas. In dwellings or dwelling units with split levels and without an intervening
door between the adjacent levels, a smoke alarm installed on the upper level shall suffice for the adjacent lower level provided
that the lower level, is less than one full story below the upper level.
B.) Smoke alarms shall be interconnected as indicated in Section R314.3
C.) The power source for smoke alarms and carbon monoxide detectors shall comply with Section R317.2.
CARBON MONOXIDE ALARMS: PURSUANT TO IRC 2018 (R315)
CARBON MONOXIDE ALARM INSTALLATION AREAS SHALL BE:
A. Must be installed outside of each separate sleeping area in the immediate vicinity of bedrooms.
B. For new construction, carbon monoxide alarms must be provided in dwelling units that contain:
B1 Contain a fuel - fired appliance.
B2 Have an attached garage with an opening that communicates with the dwelling unit.
C. Any Alterations, Interior Remodels, Repairs or New Additions that require a permit must comply with new construction
requirements.
THIS STRUCTURE UNDER IRC-2018 SQ FT MIN REQUIREMENTS IS REQUIRED TO HAVE A FIRE SUPRESSION SYSTEM
INSTALLED IN RESIDENTIAL STRUCTURES OVER 5000 SQ FT.
Foot Vent
Below Floor
Slope at 1/4"per foot
Vent Up
in Wall
Cleanout
High Water Level-
Rim of Sink or
the counter top
Bring Vent Up as High as Possible90 Deg Fitting
VentWaste
SINK
Cleanout
"Y" Fitting
Waste Below Floor
Cleanout
ISLAND VENT DETAIL
ISL
Vt
p
2
WASHING
MACHINE
ROUGH-IN UNIT
2" STAND
PIPE
12" x 12"
ACCESS PANEL
1-1/2"
VENT
2" DRAIN TO
SAN. SEWER
CLEANOUT
2"
P-TRAP
HOSE BIBB
SUPPLY
FITTINGS
FINISHED
FLOOR
COLDHOT
AP
P
R
O
X
.
3
6
"
A
F
F
WASHING MACHINE HOOK-UP
Electrical Notes:
1. Verify all fixture types and mounting locations with the owner prior to
installation of electrical boxes and switches
or placing fixtures at rough-in stage.
2. Allow 6" clear for all window and door trim from all wall mounted electrical
plates.
3. Maintain N.E.C. minimum clearances in front of all safety switches and
panels.
4. Contractor shall verify and coordinate all mounting heights of devices
mounted in or above casework with the specific equipment to be used by the
Owner.
5. Contractor shall verify all equipment types and locations with the owner
and the circuit requirements for all mechanical and kitchen equipment and
other appliances, motors,etc. Provide dimmer control slide types as directed
by owner. Provide typed directory cards at each panel.
6. Switches and dimmers shall be "rocker type switch with slide type
dimmer."
7. Coordinate all metering and service devices with local utilities.
8. Provide and coordinate connections and power for low voltage landscape
lighting system and motorized attic vents as may be used by the owner.
7'
-
5
"
7'-7"2'-6"
1'-3"2'-6"1'-3"
3'
-
0
"
7"
3'
-
0
"
2F
C-1
10
'
-
1
"
HL
C-1
3'
-
0
"
8"
3'
-
6
"
2'
-
1
1
"
2'-6"2'-6"
10
'
-
1
"
PB
C-1
3'-6"
5'
-
7
"
4'
-
6
"
4'
-
7
"
3'
-
0
"
2'
-
6
"
4'
-
7
"
10
'
-
1
"
6'-3"2'-8"3'-6"
LR
C-1
6'
-
7
"
3'
-
6
"
3'-0"1'-6"3'-5"1'-6"3'-0"
10
'
-
1
"
3'-0"1'-6"3'-5"1'-6"3'-0"
12'-5"
10
'
-
1
"
OPEN
AREA
LR
C-2
2'
-
3
"
9"
3'
-
7
"
3'
-
6
"
2'-3"3'-8"2'-2"
4'
-
1
1
"
5'
-
2
"
10
'
-
1
"
MB
C-1
3'
-
0
"
7'
-
1
"
2'-0"2'-0"4'-0"
MB
C-3
7'
-
1
"
3'
-
0
"
2'-0"4'-0"2'-0"
MB
C-2
3'
-
0
"
1'
-
6
"
3'
-
6
"
2'
-
0
"
2'-0"
2'-0"3'-0"3'-1"
10
'
-
1
"
P
C-1
2'-0"2'-0"
2'-0"
4'
-
6
"
1'
-
7
"
2'
-
4
"
1'
-
8
"
10
'
-
1
"
P
C-2
3'-1"2'-0"
10
'
-
1
"
3'
-
0
"
1'
-
6
"
3'
-
6
"
3'
-
0
"
3'
-
1
"
1'
-
1
1
"
2'
-
0
"
2'-4"9"2'-0"
P
C-3
8"
4'
-
0
"
2'
-
5
"
1'-3"2'-11"1'-3"
1'-3"2'-11"1'-3"
3'
-
0
"
5'
-
6
"
1'
-
7
"
10
'
-
1
"
ER
C-1
6'
-
8
"
3'
-
4
"
8'
-
1
"
K
C-1
HIDDEN
ACCESS
REFRIG - USE EXISTING
2x2 FRAME SIDES FOR
LGR FUTURE REFRIG
9'-5"
3'
-
6
"
2'-6"3'-2"3'-1"3'-2"
3'
-
0
"
1'
-
6
"
3'
-
6
"
2'
-
1
"
3'
-
0
"
1'
-
6
"
3'
-
6
"
2'
-
1
"
1'
-
5
"
2'
-
4
"
2'
-
1
0
"
1'
-
5
"
2'
-
1
"
10
'
-
1
"
HOOD NOT
SPECIFIC
K
C-2
3'
-
0
"
1'-0"2'-0"3'-0"2'-0"
K
C-3
3'
-
0
"
3'-9"2'-3"1'-9"1'-3"
K
C-4
FREEZEPROOF WALL HYDRANT
N.T.S.
CONNECTION
°1°" INLET
° 8 °"
WALL
FINISHED
(IF USED)
WALL CLAMP
FLANGE
WALL BOX
INSIDE
(BACK) OF
WALL
HB
PRINT DATES
FINAL PRINT - 12/09/25
DESIGN DRAWN BY
Kirk A. ThomasKirk A. ThomasKirk A. ThomasKirk A. Thomas
To
t
h
e
b
e
s
t
o
f
m
y
k
n
o
w
l
e
d
g
e
t
h
e
s
e
p
l
a
n
s
a
r
e
d
r
a
w
n
t
o
c
o
m
p
l
y
w
i
t
h
t
h
e
c
o
d
e
r
e
q
u
i
r
e
m
e
n
t
s
f
o
r
th
e
i
r
i
n
t
e
n
d
e
d
u
s
e
b
y
o
w
n
e
r
'
s
a
n
d
/
o
r
b
u
i
l
d
e
r
'
s
s
p
e
c
if
i
c
a
t
i
o
n
s
,
a
n
y
c
h
a
n
g
e
s
m
a
d
e
o
n
o
r
t
o
t
h
e
m
af
t
e
r
p
r
i
n
t
s
a
r
e
s
e
a
l
e
d
w
i
l
l
b
e
d
o
n
e
a
t
t
h
e
o
w
n
e
r
'
s
a
n
d
/
o
r
b
u
i
l
d
e
r
'
s
e
x
p
e
n
c
e
a
n
d
r
e
s
p
o
n
s
i
b
i
l
i
t
y
.
Th
e
c
o
n
t
r
a
c
t
o
r
s
h
a
l
l
v
e
r
i
f
y
a
l
l
d
i
m
e
n
s
i
o
n
s
a
n
d
e
n
c
l
os
e
d
d
e
t
a
i
l
d
r
a
w
i
n
g
s
.
R
e
f
e
r
I
n
s
t
a
l
l
a
t
i
o
n
o
f
a
l
l
ma
t
e
r
i
a
l
s
t
o
m
a
n
u
f
a
c
t
u
r
e
s
a
n
d
c
o
d
e
r
e
q
u
i
r
m
e
n
t
s
f
o
r
ea
c
h
i
t
e
m
s
a
t
t
a
c
h
m
e
n
t
t
o
t
h
e
s
t
r
u
c
t
u
r
e
re
q
u
a
r
d
l
e
s
s
o
f
d
e
t
a
i
l
s
h
o
w
n
.
D
e
t
a
i
l
s
a
r
e
n
o
t
s
p
e
c
i
fi
c
t
o
s
t
r
u
c
t
u
r
e
d
r
a
w
n
,
d
e
t
a
i
l
s
a
r
e
d
r
a
w
n
a
s
pe
r
s
p
e
c
t
i
v
e
c
u
t
a
w
a
y
v
i
e
w
s
a
n
d
i
n
n
o
w
a
y
s
h
o
w
m
a
t
e
r
i
al
i
t
e
m
s
a
s
f
i
n
i
s
h
e
d
i
n
s
t
a
l
l
e
d
re
p
r
e
s
e
n
t
a
t
i
o
n
.
k
.
a
.
t
.
D
e
s
i
g
n
s
I
n
c
.
i
s
n
o
t
l
i
a
b
l
e
f
or
e
r
r
o
r
s
b
a
s
e
d
u
p
o
n
p
e
r
s
o
n
a
l
i
n
t
e
r
p
r
e
t
a
t
i
o
n
of
a
n
y
d
e
t
a
i
l
,
t
e
x
t
i
t
e
m
,
o
r
s
y
m
b
o
l
u
s
e
d
i
n
t
h
e
c
r
e
at
i
o
n
o
f
t
h
e
s
e
d
o
c
u
m
e
n
t
s
.
W
h
i
l
e
e
v
e
r
y
e
f
f
o
r
t
ha
s
b
e
e
n
m
a
d
e
i
n
t
h
e
p
r
e
p
a
r
a
t
i
o
n
o
f
t
h
i
s
p
l
a
n
t
o
a
v
oi
d
m
i
s
t
a
k
e
s
,
t
h
e
m
a
k
e
r
c
a
n
n
o
t
g
u
a
r
a
n
t
e
e
ag
a
i
n
s
t
h
u
m
a
n
e
r
r
o
r
.
T
h
e
L
i
c
.
C
o
n
t
r
a
c
t
o
r
/
O
w
n
e
r
s
o
f
th
e
p
r
o
j
e
c
t
m
u
s
t
c
h
e
c
k
a
l
l
d
i
m
e
n
s
i
o
n
s
a
n
d
de
t
a
i
l
s
p
r
i
o
r
t
o
c
o
n
s
t
r
u
c
t
i
o
n
a
n
d
b
e
s
o
l
e
l
y
r
e
s
p
o
n
s
ib
l
e
u
p
o
n
i
s
s
u
e
d
p
e
r
m
i
t
.
A
l
l
i
n
f
o
r
m
a
t
i
o
n
co
n
t
a
i
n
e
d
w
i
t
h
i
n
t
h
e
s
e
p
l
a
n
s
i
s
s
u
b
j
e
c
t
t
o
c
h
a
n
g
e
b
as
e
o
n
c
o
d
e
r
e
q
u
i
r
e
m
e
n
t
s
a
n
d
p
e
r
m
i
t
t
i
n
g
ju
r
i
s
d
i
c
t
i
o
n
I
n
t
e
r
p
r
e
t
a
t
i
o
n
.
Page #Page #Page #Page #
PL
A
N
S
C
A
L
E
:
BA
S
E
@
1
/
4
"
=
1
'
-
0
'
'
U.
O
.
N
.
S
C
A
L
E
M
A
Y
V
A
R
Y
P
E
R
P
L
A
N
OR
P
E
R
D
E
T
A
I
L
(
N
O
T
S
P
E
C
I
F
I
C
)
Building Code: IRC2018
Design Wind Speed: 130 mph
ASD - ASCE 7-10
Design Wind Speed: 160 MPH
Ultimate - ASCE 7-16
Req. Glazing & Door Design
Pressures (DP's) 50 psf
All Doors and Glazing Installed
shall be Impact Rated
Flood Zone: FIRM - X
Finish Floor Elevation:
Min. 36'' A.CL.RW.
Mean Roof Height:
I,
L
a
r
r
y
M
.
O
l
i
v
e
r
,
P
.
E
.
,
L
i
c
e
n
s
e
N
o
.
1
2
6
7
8
Ce
r
t
i
f
y
t
h
a
t
t
h
e
s
t
r
u
c
t
u
r
a
l
p
o
r
t
i
o
n
s
o
f
t
h
i
s
se
t
o
f
c
o
n
s
t
r
u
c
t
i
o
n
d
o
c
u
m
e
n
t
s
h
a
v
e
b
e
e
n
re
v
i
e
w
e
d
u
n
d
e
r
m
y
r
e
s
p
o
n
s
i
b
l
e
c
h
a
r
g
e
,
de
s
i
n
a
t
e
d
b
y
d
e
s
i
g
n
,
t
o
c
o
m
p
l
y
w
i
t
h
t
h
e
en
g
i
n
e
e
r
i
n
g
r
e
q
u
i
r
e
m
e
n
t
s
o
f
t
h
e
In
t
e
r
n
a
t
i
o
n
a
l
R
e
s
i
d
e
n
t
i
a
l
B
u
i
l
d
i
n
g
C
o
d
e
,
20
1
8
L
a
t
e
s
t
E
d
i
t
i
o
n
@
1
3
0
/
1
6
0
-
m
p
h
3
se
c
g
u
s
t
w
i
n
d
l
o
a
d
r
a
t
i
n
g
.
La
r
r
y
M
.
O
l
i
v
e
r
E
n
t
e
r
p
r
i
s
e
s
I
n
c
.
72
2
8
O
a
k
b
r
i
a
r
D
r
i
v
e
S
o
u
t
h
Mo
b
i
l
e
,
A
L
.
3
6
6
1
9
PE
R
M
I
T
J
U
R
I
S
D
I
C
T
I
O
N
:
CI
T
Y
O
F
F
A
I
R
H
O
P
E
B.
F
.
E
.
:
1
2
'
'
A
.
C
L
.
R
W
FL
O
O
D
Z
O
N
E
:
"
X
"
CO
N
T
R
A
C
T
O
R
:
S
T
E
V
E
J
O
N
E
S
C
O
N
T
R
A
C
T
O
R
PR
O
J
E
C
T
:
R
E
M
O
D
E
L
S
I
N
G
L
E
F
A
M
I
L
Y
R
E
S
.
CL
I
E
N
T
:
L
U
C
I
N
D
A
&
C
H
I
P
C
H
A
P
P
E
L
L
E
LO
C
A
T
I
O
N
:
F
A
I
R
H
O
P
E
,
A
L
.
PH
Y
S
I
C
A
L
A
D
D
R
E
S
S
:
2
1
0
G
A
Y
F
E
R
C
T
.
Base Slab Elev: 24''' A.F.G. (Varies)
FINAL REVIEW - 12/04/25
PRELIM. REVIEW -09/16/25
PRELIM. REVIEW - 11/04/25
PRELIM. REVIEW - 10/07/25
PRELIM. REVIEW -09/17/25
c
2
0
2
5
C
O
P
Y
R
I
G
H
T
B
Y
K
.
A
.
T
.
D
e
s
i
g
n
s
I
n
c
.
T
h
e
s
e
d
r
a
w
i
ng
s
a
r
e
N
O
T
T
O
B
E
re
p
r
o
d
u
c
e
d
o
r
c
o
p
i
e
d
i
n
a
n
y
f
o
r
m
w
h
a
t
s
o
e
v
e
r
w
i
t
h
o
u
t
t
h
e
w
r
i
t
t
e
n
pe
r
m
i
s
s
i
o
n
o
f
K
.
A
.
T
.
D
e
s
i
g
n
s
I
n
c
.
-
A
N
Y
D
U
P
L
I
C
A
T
I
O
N
I
S
P
R
O
H
I
B
I
T
E
D
A
N
D
PU
N
I
S
H
A
B
L
E
U
N
D
E
R
F
E
D
E
R
A
L
L
A
W
.
T
h
e
p
u
r
c
h
a
s
e
r
h
a
s
t
h
e
ri
g
h
t
t
o
O
N
E
US
E
f
o
r
p
e
r
m
i
t
t
i
n
g
p
u
r
p
o
s
e
s
,
a
n
y
f
u
t
u
r
e
u
s
e
o
f
t
h
e
pl
a
n
,
i
d
e
a
s
,
e
l
e
v
a
t
i
o
n
s
,
co
n
t
e
n
t
s
,
o
r
c
h
a
n
g
e
s
t
o
d
e
s
i
g
n
a
r
e
t
h
e
p
r
o
p
e
r
t
y
o
f
K
.
A
.
T
.
D
e
s
i
g
n
s
I
n
c
.
AN
D
M
U
S
T
B
E
A
U
T
H
O
R
I
Z
E
D
B
Y
K
.
A
.
T
.
D
e
s
i
g
n
s
I
n
c
.
A
N
Y
U
NA
T
H
O
R
I
Z
E
D
U
S
E
WI
L
L
B
E
P
U
N
I
S
H
A
B
L
E
U
N
D
E
R
F
E
D
E
R
A
L
C
O
P
Y
R
I
G
H
T
L
A
W
S
.
THE INTERIOR DRAWINGS SHOWN ARE PERSPECTIVE VIEWS ONLY AND IN NO WAY REPRESENT THE STYLE, TYPE, OR CHOICE OF MATERIALS SHOWN, NOR ARE THEY THE FINAL
APPLICATIONS TO BE INSTALLED. PLEASE REFER ALL CHOICES TO THE OWNERS FOR THEIR APPROVAL OF SPECIFICATIONS OF MATERIALS TO BE FINAL AS INSTALLED ITEMS.
CA
B
I
N
E
T
V
I
E
W
S
w
/
E
L
E
C
NO
T
E
S
&
I
E
C
C
N
O
T
E
S
A 1.14A 1.14A 1.14A 1.14
Page 33 of 63
GENERAL NOTES
1. ALL DESIGN (INCLUDING WIND LOADS) AND CONSTRUCTION SHALL
COMPLY WITH THE 2018 INTERNATIONAL RESIDENTIAL CODE FOR ONE
AND TWO FAMILY DWELLINGS, LOCAL CODES, ORDINANCES, AND
AMENDMENTS. THE DESIGN CRITERIA FOR ALL CONSTRUCTION SHALL
COMPLY FULLY WITH THE CODE.
2. APPLICABILITY OF THESE HURRICAN RESISTANT RESIDENTIAL
STANDARDS SHALL BE LIMITED TO THE FOLLOWING CONDITIONS:
BUILDING CODE: 2018 INTERNATIONAL BUILDING CODE (IBC)
2018 INTERNATIONAL RESIDENTIAL CODE (IRC)
2018 INTERNATIONAL MECHANICAL CODE (IMC)
2018 INTERNATIONAL PLUMBING CODE (IPC)
2017 NATIONAL ELECTRIC CODE
DESIGN LOADS:
LIVE LOADS:
ATTICS WITH STORAGE 20 PSF
ATTICS WITHOUT STORAGE 10 PSF
DECKS 60 PSF
FLOORS 40 PSF
ROOFS 25 PSF
STAIRS 100 PSF
GARAGE FLOORS 40 PSF (3,000 LB. POINT LOAD)
DEAD LOADS:
FLOORS 20 PSF
ROOF 15 PSF
WIND LOAD: THE FOLLOWING LOAD CRITERIA AND FACTORS HAVE BEEN
USED IN THE DESIGN OF THIS STRUCTURE:
WIND CODE PER SECTION R301 ASCE 7-16
BASIC WIND SPEED - ULTIMATE 160 MPH
IMPORTANCE FACTOR 1
EXPOSURE CATEGORY B
BUILDING CATEGORY II
3. INSULATION
FLOOR SYSTEMS (ALL) R19
ATTIC FLOOR R38
CEILING R38 Blown Insulation
WALLS R15 (2X4) R21 (2X6)
FURNACE DUCTS R8 (UNHEATED SPACE)
4. CONTRACTOR AND OWNER SHALL VERIFY ALL DIMENSIONS PRIOR TO
START OF CONSTRUCTION. IN CASE OF DISCREPANCY, NOTIFY
DESIGNER AND ENGINEER OF RECORD PRIOR TO PROCEEDING.
5. AT CONSTRUCTION ISSUE, THESE DRAWINGS AND DETAILS REPRESENT
COMPONENTS IN THEIR FINAL AND FINISHED STATE FOR
CONSTRUCTION. TEMPORARY BRACING METHODS, SAFETY
PRECAUTIONS, AND MECHANICAL REQUIREMENTS USED TO ERECT
COMPONENTS ARE THE SOLE RESPONSIBILITY OF THE CONTRACTOR OR
SUBCONTRACTOR PERFORMING WORK.
6. THE DETAILS AND SPECIFICATIONS PROVIDED ARE AN OUTLINE OF
MINIMUM MATERIAL REQUIREMENTS AND THEIR APPLICATION.
MANUFACTURER SPECIFICATIONS AND LOCAL CODE REQUIREMENTS,
WHEN IN EXCESS OF MINIMUM SPECIFICATION, SHALL CONTROL. IT IS
THE CONTRACTOR'S RESPONSIBILITY TO REVIEW AND SUBMIT ALL
SHOP DRAWINGS AND REPORT ALL DISCREPANCIES TO THE DESIGNER
AND ENGINEER OF RECORD OR OWNER PRIOR TO CONTINUATION OF
CONSTRUCTION.
7. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE A SAFE
AND ORGANIZED JOB SITE. THE DESIGNER AND ENGINEER OF RECORD
SHALL ASSUME NO LIABILITY IN REGARD TO SAFETY.
8. IF UNFORSEEN CONDITIONS ARE ENCOUNTERED DURING
CONSTRUCTION, THE CONTRACTOR SHALL IMMEDIATELY CONSULT
THE DESIGNER AND ENGINEER OF RECORD.
9. THE DESIGN, ADEQUACY, AND SAFETY OF ERECTION BRACING,
SHORING, AND TEMPORARY SUPPORTS IS THE SOLE RESPONSIBILITY OF
THE CONTRACTOR. THE STRUCTURE AND FOUNDATION ARE DESIGNED
FOR A COMPLETED CONDITION ONLY AND THEREFORE REQUIRES
ADDITIONAL SUPPORT TO MAINTAIN STABILITY PRIOR TO
COMPLETION.
10. AS A MINIMUM, ALL CONCRETE OR MASONRY FOOTERS TO COMPLY
WITH MINIMUM WIDTH OF CONCRETE OR MASONRY FOOTERS OF THE
CURRENTLY ADOPTED IRC UNLESS OTHERWISE NOTED.
11. INSTALL FULL DEPTH BLOCK (MATCH RAFTER DEPTH) @ 48" O.C. IN
FIRST TWO FRAMING SPACES OF ROOF SYSTEM AT ALL GABLE ENDS OF
ROOF. INSTALL BLOCKING AT PANEL EDGES OF ROOF DECKS AND
FASTEN WITH 8D COMMON NAILS @ 6" O.C. INTO BLOCKING.
12. INSTALL FULL DEPTH BLOCK (MATCH JOIST DEPTH) @ 24" O.C. IN FIRST
TWO FRAMING SPACES OF CEILING JOIST WHERE CEILING JOIST RUN
PARALLEL TO EXTERIOR WALL. INSTALL FULL DEPTH BLOCKING AND
FASTEN AS NOTED IN FASTENER SCHEDULE UNLESS OTHERWISE
NOTED.
ROOF COVERING NOTES:
1. ROOF DECK SHALL BE MINIMUM 7/16" OSB OR 1/2" CDX PLYWOOD
ATTACHED PER REQUIREMENT SHOWN OF FASTENER SCHEDULE.
INSTALL SIMPSON PSC CLIPS OR USP MODEL PC SHEATHING CLIPS AT
ALL UNSUPPORTED EDGES OF ROOF DECK (TWO PER SPAN).
2. ENTIRE ROOF DECK SHALL BE COVERED WITH A FULL LAYER OF
SELF-ADHERING POLYMER MODIFIED BITUMEN MEMBRANE (PEEL AND
SEAL) MEETING ASTM D1970 REQUIREMENTS FOR PLYWOOD OR OSB
ROOF DECKING OR ALL DECKING SEAMS TO BE SEALED WITH 4" PEEL &
SEAL WITH TEAR RESISTANT UNDERLAYMENT APPLIED TO DECKING
PER MANUFACTURER'S INSTRUCTIONS.
GENERAL NOTES (CONTINUED)
13. THE AREA OF THE FLOOR FOR GARAGES AND/OR CARPORTS USED FOR
PARKING AUTOMOBILES OR VEHICLES SHALL BE SLOPED TO FACILITATE
THE MOVEMENT OF LIQUIDS TO A DRAIN OR TOWARD THE MAIN VEHICLE
ENTRY DOORWAY.
14. SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER CONVEYANCE
OR OTHER APPROVED POINT OF COLLECTION SO AS NOT TO CREATE A
HAZARD. LOTS SHALL BE GRADED SO AS TO DRAIN SURFACE WATER AWAY
FROM FOUNDATION WALLS. THE GRADE AWAY FROM FOUNDATION WALLS
SHALL FALL A MINIMUM OF 6 INCHES WITHIN THE FIRST 10 FEET.
15. EXTERIOR FOUNDATION WALLS THAT RETAIN EARTH AND ENCLOSE
HABITABLE OR USABLE SPACES LOCATED BELOW GRADE SHALL BE
WATERPROOFED WITH A MEMBRANE EXTENDING FROM THE TOP OF THE
FOOTING TO FINISH GRADE. THE MEMBRANE SHALL CONSIST OF 2-PLY HOT
MOPPED FELTS, 55 POUND ROLL ROOFING, 6 MIL POLYVINYL CHLORIDE, 6
MIL POLYETHYLENE OR 40 MIL POLYMER-MODIFIED ASPHALT. THE JOINTS
IN THE MEMBRANE SHALL BE LAPPED OR SEALED WITH AN ADHESIVE
COMPATIBLE WITH THE MEMBRANE MATERIAL.
16. ENCLOSED ATTICS AND EXCLOSED RAFTER SPACES FORMED WHERE
CEILINGS ARE APPLIED DIRECTLY TO THE UNDERSIDE OF ROOF RAFTERS
SHALL HAVE CROSS VENTILATION FOR EACH SEPARATE SPACE BY
VENTILATING OPENINGS PROTECTED AGAINST THE ENTRANCE OF RAIN OR
SNOW. VENTILATING OPENINGS SHALL BE PROTECTED WITH
CORROSION-RESISTANT WIRE MESH, WITH 1/8" MINIMUM TO 1/4" MAXIMUM
OPENINGS.
17. THE TOTAL NET FREE VENTILATING AREA SHALL NOT BE LESS THAN 1 TO 150
OF THE AREA OF THE SPACE VENTILATED EXCEPT THAT THE TOTAL AREA IS
PERMITTED TO BE REDUCED TO 1 TO 300 PROVIDED AT LEAST 50 PERCENT
AND NOT MORE THAN 80 PERCENT OF THE REQUIRED VENTILATING AREA IS
PROVIDED BY VENTILATORS LOCATED IN THE UPPER PORTION OF THE TO BE
VENTILATEDAT LEAST 3 FEET ABOVE EAVE OR CORNICE VENTS WITH THE
BALANCE OF THE REQUIRED VENTILATION PROVIDED BY EAVE OR CORNICE
VENTS.
TIMBER NOTES:
1. UNLESS OTHERWISE NOTED, ALL LUMBER SHALL BE SOUTHERN YELLOW
PINE #2 GRADE OR BETTER WITH A MAXIMUM MOISTURE COUNT OF 19%.
2. WOOD FRAMING AND COLUMNS 5"X5" AND LARGER SHALL BE #1 STRESS
RATED SOUTHERN YELLOW PINE OR EQUIVALENT WITH THE MINIMUM
FOLLOWING PROPERTIES: Fb = 1350 psi Ft= 900 psi Fv= 90 psi Fc = 375 psi
Fdl = 825 psi E = 1,500,000 psi
3. ALL TIMBER WALL FRAMING SHALL BE AS FOLLOWS: 2x4 WALL STUD AND
PLATES SPRUCE PINE SHALL BE NO. 3 GRADE OR BETTER STUD GRADE
MATERIAL WITH THE MINIMUM FOLLOWING PROPERTIES: Fb = 675 PSI Ft =
350 PSI Fv = 70 PSI Fc = 425 PSI Fdl = 726 PSI E = 1,200,000 PSI
4. ALL LUMBER IN CONTACT WITH CONCRETE OR MASONRY SHALL BE
PRESSURE TREATED. ALL LUMBER EXPOSED TO EXTERIOR ENVIRONMENTAL
CONDITIONS SHALL BE PRESSURE TREATED.
5. ALL ENGINEERED WOOD BEAMS SHALL BE SIZED, MANUFACTURED,
INSTALLED, AND BRACED TO COMPLY WITH THE MANUFACTURER'S
RECOMMENDATIONS.
6. LAMINATED VENEER LUMBER BEAMS SHALL HAVE THE FOLLOWING
MINIMUM DESIGN PROPERTIES/CONDITIONS: Fb = 3100 psi Fv = 290 psi Fc= 750
psi Fdl = 3000 psi E = 2,000,000 psi
7. ALL BUILT-UP STUD PACKS, BEAMS, AND JOISTS SHALL BE NAILED IN STRICT
ACCORDANCE WITH AF&PA'S (AMERICAN FOREST AND PAPER ASSOCIATION)
AND THE NATIONAL DESIGN SPECIFICATIONS (NDS) FOR WOOD
CONSTRUCTION.
8. MULTIPLE PLIES SHALL BE NAILED TOGETHER WITH TWO ROWS OF 20d
NAILS -ONE ROW NEAR THE TOP EDGE AND ANOTHER AT THE BOTTOM.
NAILS IN EACH ROW SHALL NOT EXCEED 12" APART. END JOINTS OF THE
NAILED LUMBER SHALL OCCUR OVER THE SUPPORTING STUD PACK
(COLUMN).
9. ALL BOLTS, NAILS, JOIST HANGERS, CLIPS, STRAPS, ETC. IN CONTACT WITH
PRESSURE TREATED LUMBER SHALL BE HOT DIPPED GALVANIZED OR
STAINLESS STEEL.
10. ALL CONNECTIONS AND HARDWARE SHALL BE INSTALLED IN STRICT
COMPLIANCE WITH MANUFACTURER'S RECOMMENDATIONS AND
SPECIFICATIONS. SIZE, QUANTITY, NUMBER, AND LOCATIONS OF FASTENERS
SHALL CONFORM TO THE MANUFACTURER'S PUBLISHED LITERATURE.
FOUNDATION NOTES:
1. A GEOTECHNICAL EVALUATION OF THE SUITABILITY OF THE EXISTING LOAD
BEARING SOILS HAS NOT BEEN PERFORMED FOR THIS PROJECT. IT IS THE
RESPONSIBILITY OF THE GENERAL CONTRACTOR TO CONSULT A
GEOTECHNICAL ENGINEER AND PROPERLY PREPARE THE SOIL FOR THE
FOUNDATION DESIGN LOADING.
2. FOUNDATION DESIGN IS BASED ON AN ASSUMED ALLOWABLE SOIL BEARING
CAPACITY OF 2500 PSF. A QUALIFIED REGISTERED PROFESSIONAL
GEOTECHNICAL ENGINEER SHALL BE RETAINED TO VERIFY SOIL BEARING
CONDITIONS PRIOR TO CONSTRUCTION.
3. THE REGISTERED GEOTECHNICAL ENGINEER OF RECORD SHALL BE
RETAINED DURING CONSTRUCTION TO INSPECT FOUNDATION EXCAVATION,
INSPECT AND MONITOR PLACEMENT OF PILINGS AND COMPACTED FILL, AND
TO MONITOR PROOF ROLLING OPERATIONS, AS REQUIRED.
4. SHOULD RECOMMENDATIONS OF GEOTECHNICAL ENGINEER DIFFER FROM
THOSE OUTLINED ABOVE, IMMEDIATELY NOTIFY DESIGNER AND ENGINEER
OF RECORD PRIOR TO PROCEEDING.
CONCRETE NOTES:
1. ALL CONCRETE AND REINFORCING STEEL SHALL FOLLOW THE
PRACTICES AND STANDARDS DESCRIBED IN THE EDITION IN EFFECT OF
THE AMERICAN CONCRETE INSTITUTE (ACI) 318 STANDARD "BUILDING
CODE REQUIREMENTS FOR REINFOCED CONCRETE".
2. ALL CONCRETE SHALL CONFORM TO ASTM C-94, LATEST EDITION, AND
SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI @28
DAY CURE. CONCRETE PLACES WITHIN A CMU WALL SHALL CONTAIN
PEA GRAVEL AGGREGATE:
3. ALL PORTLAND CEMENT SHALL CONFORM TO ASTM C150, TYPE I OR
TYPE II.
4. ALL AGGREGATE FOR NORMAL WEIGHT CONCRETE SHALL MEET ASTM
C33.
5. SLUMP SHALL BE FROM 5-6 INCHES MAXIMUM WITH A WATER-CEMENT
RATIO LESS THAN .55. THE USE OF A SUPERPLASTICIZER IS APPROVED
FOR POURING OF WALLS.
6. ALL WELDED WIRE FABRIC REINFORCEMENT STEEL SHALL CONFORM
TO ASTM A185.
7. ALL REINFORCING SHALL BE DETAILED, FABRICATED, AND PLACED
PER CRSI AND ACI STANDARDS, INCLUDING CONCRETE CORNER AND
BAR SUPPORTS. LAP BAR AT ALL SPLICES, INCLUDING CORNER BARS
AND DOWELS, IN ACCORDANCE WITH SPLICE SCHEDULE OR IN LIEU
THEREOF 40 BAR DIAMETERS. LAP WELDED WIRE MESH FABRIC 6" OR
ONE FULL MESH, WHICHEVER IS GREATER.
8. CONCRETE COVER OVER REINFORCING SHALL CONFORM TO THE
REQUIREMENTS OF THE LATEST EDITION AF ACI 318, UNLESS NOTED
OTHERWISE: BELOW GRADE (UNFORMED): 3" BELOW GRADE FORMED:
2" WALLS AND SLABS: 1 1/2"
9. ALL CMU BLOCK SHALL BE CONSTRUCTED IN RUNNING BOND AND
SHALL HAVE HORIZONTAL WIRE REINFOCEMENT EVERY OTHER
COURSE. CONCRETE WITHIN CMU BLOCK SHALL CONTAIN PEA
GRAVEL.
10. ALL MORTAR SHALL BE PORTLAND CEMENT TYPE S.
11. VERTICAL AND HORIZONTAL REINFORCEMENT IS TO BE CONTINUOUS
AND LAPPED A MINIMUM OF 48 BAR DIAMETERS.
12. ALL ANCHOR BOLT MATERIAL SHALL BE ASTM F1554 UNLESS NOTED
OTHERWISE.
WIND BORNE DEBRIS PROTECTION
1. WINDOWS IN BUILDING LOCATED IN WIND BORNE DEBTIS REGIONS
SHALL HAVE GLAZED OPENINGS PROTECTED FROM WIND BORNE
DEBRIS.
2. ALL WINDOWS AND DOORS SHALL BE DESIGNED CAPABLE OF
RESISTING A WIND LOAD OF 130 MPH, 3 SECOND GUST.
3. GLAZING IN RESIDENCES REQUIRING PROTECTION SHALL BE
PROTECTED WITH AN IMPACT PROTECTIVE SYSTEM OR SHALL BE
IMPACT RESISTANT WINDOWS.
4. GLAZED OPENINGS PROTECTION FOR WIND BORNE DEBRIS SHALL
MEET THE REQUIREMENTS OF THE LARGE MISSILE TEST OF ASTM E 1996
AND OF ASTM E 1886.
ATTIC ACCESS
1. ATTIC ACCESS SHALL NOT BE LESS THAN 22 INCHES BY 30 INCHES AND
SHALL BE LOCATED IN A HALLWAY OR OTHER READILY ACCESSIBLE
LOCATION. A 30 INCH MINIMUM UNOBSTRUCTED HEADROOM AT THE
ATTIC SPACE SHALL BE PROVIDED AT POINT ABOVE THE ACCESS
OPENING.
2. FOR ATTICS WITH ABOVE CEILING PLUMBING OR MECHANICAL
EQUIPMENT, A FIXED LADDER OR INDUSTRIAL GRADE DISAPPEARING
STAIRWAY SHALL BE PROVIDED.
TRUSS NOTES:
1. ALL WOOD TRUSSES TO BE DESIGNED AND MANUFACTURED BY A
TRUSS SUPPLIER WHO IS A MEMBER OF THE TRUSS PLATE INSTITUTE
OR WHO USES METAL PLATES FROM A MANUFACTURER WHO IS A
MEMBER.
2. ALL BRACING, QUALITY CONTROL, AND ERECTION OF TRUSSES SHALL
CONFORM TO THE TRUSS MANUFACTURER'S GUIDELINES AND
SPECIFICATIONS AS STATED ON THE TRUSS SHOP DRAWINGS.
3. TRUSS SHOP DRAWING SUBMITTAL SHALL BE SIGNED AND SEALED BY
AN ENGINEER REGISTERED IN THE STATE OF THE PROJECT'S LOCATION.
4. SHOP DRAWINGS TO INCLUDE PLAN SHOWING LAYOUT OF TRUSSES,
DETAILS OF TRUSSES, BRACING, AND ANY OTHER INFORMATION
REQUIRED TO COMPLETE THE TRUSS INSTALLATION FOR THE PROJECT.
5. PROVIDE HEADERS AS DETERMINED BY ACCEPTABLE ENGINEERING
DESIGN STANDARDS AT AREAS WHERE THE TRUSSES REQUIRE
HEADERS TO ADJACENT TRUSSES.
6. TRUSS DESIGNER SHALL BE RESPONSIBLE FOR VERIFYING ALL
REQUIRED MEASUREMENTS FROM THE PLANS BEFORE COMPLETION OF
TRUSS DRAWINGS. DRAWINGS MUST BE APPROVED BY OWNER PRIOR
TO START OF CONSTRUCTION OF TRUSSES.
7. TRUSS MANUFACTUER IS RESPONSIBLE FOR DESIGN OF BRACINGS OF
TRUSSES AND UPLIFT CONNECTIONS.
TYPICAL CONNECTOR SUMMARY
1. CONNECTOR REFERENCED NUMBERS ARE SIMPSON STRONG-TIE
COMPANY OR UNITED STEEL PRODUCTS (USP) LUMBER CONNECTORS.
2. ALL CONNECTORS AND HARDWARE SHALL BE INSTALLED IN STRICT
COMPLIANCE WITH THE MANUFACTURER'S RECOMMENDATIONS.
SIZE, QUANTITY, AND LOCATION OF ALL NAILS AND FASTENERS
SHALL CONFORM TO THE MANUFACTURER'S PUBLISHED
LITERATURE.
3. SIMPSON SPH4 / SPH6 OR USP SPTH4 / SPTH6 AT BOTTOM AND TOP OF
EXTERIOR STUDS @32" O.C. UNLESS OTHERWISE NOTED.
4. FRONT AND REAR PORCHES - PORCH COLUMNS (6"X6" OR 8"X8")
SHALL BE ANCHORED THE BEAM WITH SIMPSON STRONG-TIE PC66
B(6") OR PC88 (8") OR EQUIVALENT USING 10 - 16D NAILS (6") - 12 - 16D
NAILS (8") UNLESS OTHERWISE NOTED. THE COLUMN SHALL BE
ANCHORED TO THE CONCRETE USING SIMPSON 6x6 OR 8x8 POST BASE
WITH 5/8" ANCHOR BOLT, MINIMUM 7" EMBEDMENT.
5. GARAGE DOOR SHALL BE DESIGNED BY MANUFACTURER FOR
DESIGN WIND REQUIREMENTS AND INSTALLED PER
MANUFACTURER'S RECOMMENDATIONS AND SPECIFICATIONS.
6. ALL PHASES OF THE WORK SHALL CONFORM TO THE MINIMUM
STANDARDS AND REQUIREMENTS OF THE LATEST ADOPTED CODE OF
THE INTERNATIONAL RESIDENTIAL CODE AND ITS RELATED
REFERENCES.
7. THE REQUIREMENTS OF THE CURRENTLY ADOPTED BUILDING CODE
AND ITS FASTENER SCHEDULE TABLE FOR STRUCTURAL MEMBERS
SHALL BE STRICTLY ADHERED TO FOR THE NAILING OF ALL WOOD
FRAMING CONSTRUCTION.
PLUMBING, HVAC, AND ELECTRICAL NOTES:
1. ALL PLUMBING WORK SHALL BE IN ACCORDANCE WITH THE
INTERNATIONAL PLUMBING CODE (IPC) 2018 EDITION AND ITS
RELATED REFERENCES.
2. ALL HVAC WORK SHALL BE IN ACCORDANCE WITH THE
INTERNATIONAL MECHANICAL CODE (IMC) 2018 EDITION AND ITS
RELATED REFERENCES.
3. ALL ELECTRICAL WORK SHALL BE IN ACCORDANCE WITH THE
INTERNATIONAL ELECTRICAL CODE (IEC) 2017 EDITION AND 2018
ENERGY CODE AND THEIR RELATED REFERENCES.
PRE-ENGINEERED FLOOR JOISTS, GIRDERS, AND BEAM NOTES
1. FLOOR JOIST, GIRDERS, I-JOIST, LVL BEAMS, AND BEAMS NOT CALLED
OUT SHALL BE ENGINEERED AND MANUFACTURED BY OTHERS.
2. SUB-FLOOR MUST BE GLUED AND NAILED TO FLOOR JOISTS.
3. THE MANUFACTURER MUST BE CONSULTED REGARDING ALL POINTS
OF BEARING OF THE JOISTS AND POINTS OF LOADS ON THE JOISTS.
4. JOIST CONNECTIONS TO SUPPORTS SHALL BE SPECIFIED BY JOIST
MANUFACTURER. CONNECTION SHALL BE DESIGNED TO CARRY THE
JOIST'S SHEAR CAPACITY. THE SUPPORT MEMBER SHALL BE
CONSIDERED IN THE CONNECTION DESIGN. THE SUPPORT MEMBER
SHALL NOT BE OVER-STRESSED IN THE CONNECTION DESIGN. THE
SUPPORT MEMBER SHALL NOT BE OVERSTRESSED AT THE JOIST
CONNECTION.
5. THE CONTRACTOR/OWNER SHALL SUBMIT CALCULATIONS AND SHOP
DRAWINGS FROM THE FLOOR JOIST MANUFACTURER THE THE
DESIGNER AND ENGINEER OF RECORD FOR REVIEW. THE SUBMITTED
CALCULATIONS AND SHOP DRAWINGS SHALL BE CERTIFIED BY A
PROFESSIONAL ENGINEER. THE ENGINEER REVIEW DOES NOT
RELIEVE THE CONTRACTOR/JOIST MANUFACTURER OF ANY
RESPONSIBILITY IN COMPLETING THE DESIGN, MANUFACTURE, AND
INSTALLATION OF FLOOR JOISTS WHICH ARE ADEQUATE FOR THIS
APPLICATION.
ENERGY
1. BATT INSULATION SHALL BE CUT NEATLY TO FIT AROUNJD PIPES
AND WIRES OR BE PLACED BEHIND PIPING & WIRING. INSULATION TO
BE STAPLED TO FACE OF STUD.
2. AIR PERMEABLE INSULATION SHALL NOT BE USED AS A SEALING
MATERIAL.
3. SPACE BETWEEN WINDOWS AND DOORS TO BE SEALED. CORNERS,
HEADERS, AND SILL PLATES TO BE SEALED.
4. RIM JOISTS TO BE INSULATED.
5. A CONTINUOUS AIR BARRIER SHALL BE INSTALLED IN THE BUILDING
ENVELOPE.
6. BREAKS OR JOINTS IN THE AIR BARRIER SHALL BE SEALED (TAPED).
7. PROGRMMABLE THERMOSTAT IS REQUIRED.
8. A MINMUM OF 75% LIGHTS USED SHALL BE HIGH EFFICACY.
9. RECESSED LIGHT FIXTURES SHALL BE SEALED TO BE AIRTIGHT.
10. MINIMUM U-FACTOR: 40. MINIMUM SHGC: 0.25.
11. PEEL & SEAL ALUMINUM BACKED TAPE REQUIRED TO BE APPLIED TO
ALL EDGES OF WINDOWS.
PRINT DATES
FINAL PRINT - 12/09/25
DESIGN DRAWN BY
Kirk A. ThomasKirk A. ThomasKirk A. ThomasKirk A. Thomas
To
t
h
e
b
e
s
t
o
f
m
y
k
n
o
w
l
e
d
g
e
t
h
e
s
e
p
l
a
n
s
a
r
e
d
r
a
w
n
t
o
c
o
m
p
l
y
w
i
t
h
t
h
e
c
o
d
e
r
e
q
u
i
r
e
m
e
n
t
s
f
o
r
th
e
i
r
i
n
t
e
n
d
e
d
u
s
e
b
y
o
w
n
e
r
'
s
a
n
d
/
o
r
b
u
i
l
d
e
r
'
s
s
p
e
c
i
f
i
c
a
t
i
o
n
s
,
a
n
y
c
h
a
n
g
e
s
m
a
d
e
o
n
o
r
t
o
t
h
e
m
af
t
e
r
p
r
i
n
t
s
a
r
e
s
e
a
l
e
d
w
i
l
l
b
e
d
o
n
e
a
t
t
h
e
o
w
n
e
r
'
s
a
n
d
/
o
r
b
u
i
l
d
e
r
'
s
e
x
p
e
n
c
e
a
n
d
r
e
s
p
o
n
s
i
b
i
l
i
t
y
.
Th
e
c
o
n
t
r
a
c
t
o
r
s
h
a
l
l
v
e
r
i
f
y
a
l
l
d
i
m
e
n
s
i
o
n
s
a
n
d
e
n
c
l
o
s
e
d
d
e
t
a
i
l
d
r
a
w
i
n
g
s
.
R
e
f
e
r
I
n
s
t
a
l
l
a
t
i
o
n
o
f
a
l
l
ma
t
e
r
i
a
l
s
t
o
m
a
n
u
f
a
c
t
u
r
e
s
a
n
d
c
o
d
e
r
e
q
u
i
r
m
e
n
t
s
f
o
r
e
a
c
h
i
t
e
m
s
a
t
t
a
c
h
m
e
n
t
t
o
t
h
e
s
t
r
u
c
t
u
r
e
re
q
u
a
r
d
l
e
s
s
o
f
d
e
t
a
i
l
s
h
o
w
n
.
D
e
t
a
i
l
s
a
r
e
n
o
t
s
p
e
c
i
f
i
c
t
o
s
t
r
u
c
t
u
r
e
d
r
a
w
n
,
d
e
t
a
i
l
s
a
r
e
d
r
a
w
n
a
s
pe
r
s
p
e
c
t
i
v
e
c
u
t
a
w
a
y
v
i
e
w
s
a
n
d
i
n
n
o
w
a
y
s
h
o
w
m
a
t
e
r
i
a
l
i
t
e
m
s
a
s
f
i
n
i
s
h
e
d
i
n
s
t
a
l
l
e
d
re
p
r
e
s
e
n
t
a
t
i
o
n
.
k
.
a
.
t
.
D
e
s
i
g
n
s
I
n
c
.
i
s
n
o
t
l
i
a
b
l
e
f
o
r
e
r
r
o
r
s
b
a
s
e
d
u
p
o
n
p
e
r
s
o
n
a
l
i
n
t
e
r
p
r
e
t
a
t
i
o
n
of
a
n
y
d
e
t
a
i
l
,
t
e
x
t
i
t
e
m
,
o
r
s
y
m
b
o
l
u
s
e
d
i
n
t
h
e
c
r
e
a
t
i
o
n
o
f
t
h
e
s
e
d
o
c
u
m
e
n
t
s
.
W
h
i
l
e
e
v
e
r
y
e
f
f
o
r
t
ha
s
b
e
e
n
m
a
d
e
i
n
t
h
e
p
r
e
p
a
r
a
t
i
o
n
o
f
t
h
i
s
p
l
a
n
t
o
a
v
o
i
d
m
i
s
t
a
k
e
s
,
t
h
e
m
a
k
e
r
c
a
n
n
o
t
g
u
a
r
a
n
t
e
e
ag
a
i
n
s
t
h
u
m
a
n
e
r
r
o
r
.
T
h
e
L
i
c
.
C
o
n
t
r
a
c
t
o
r
/
O
w
n
e
r
s
o
f
t
h
e
p
r
o
j
e
c
t
m
u
s
t
c
h
e
c
k
a
l
l
d
i
m
e
n
s
i
o
n
s
a
n
d
de
t
a
i
l
s
p
r
i
o
r
t
o
c
o
n
s
t
r
u
c
t
i
o
n
a
n
d
b
e
s
o
l
e
l
y
r
e
s
p
o
n
s
i
b
l
e
u
p
o
n
i
s
s
u
e
d
p
e
r
m
i
t
.
A
l
l
i
n
f
o
r
m
a
t
i
o
n
co
n
t
a
i
n
e
d
w
i
t
h
i
n
t
h
e
s
e
p
l
a
n
s
i
s
s
u
b
j
e
c
t
t
o
c
h
a
n
g
e
b
a
s
e
o
n
c
o
d
e
r
e
q
u
i
r
e
m
e
n
t
s
a
n
d
p
e
r
m
i
t
t
i
n
g
ju
r
i
s
d
i
c
t
i
o
n
I
n
t
e
r
p
r
e
t
a
t
i
o
n
.
Page #Page #Page #Page #
PL
A
N
S
C
A
L
E
:
BA
S
E
@
1
/
4
"
=
1
'
-
0
'
'
U.
O
.
N
.
S
C
A
L
E
M
A
Y
V
A
R
Y
P
E
R
P
L
A
N
OR
P
E
R
D
E
T
A
I
L
(
N
O
T
S
P
E
C
I
F
I
C
)
Building Code: IRC2018
Design Wind Speed: 130 mph
ASD - ASCE 7-10
Design Wind Speed: 160 MPH
Ultimate - ASCE 7-16
Req. Glazing & Door Design
Pressures (DP's) 50 psf
All Doors and Glazing Installed
shall be Impact Rated
Flood Zone: FIRM - X
Finish Floor Elevation:
Min. 36'' A.CL.RW.
Mean Roof Height:
I,
L
a
r
r
y
M
.
O
l
i
v
e
r
,
P
.
E
.
,
L
i
c
e
n
s
e
N
o
.
1
2
6
7
8
Ce
r
t
i
f
y
t
h
a
t
t
h
e
s
t
r
u
c
t
u
r
a
l
p
o
r
t
i
o
n
s
o
f
t
h
i
s
se
t
o
f
c
o
n
s
t
r
u
c
t
i
o
n
d
o
c
u
m
e
n
t
s
h
a
v
e
b
e
e
n
re
v
i
e
w
e
d
u
n
d
e
r
m
y
r
e
s
p
o
n
s
i
b
l
e
c
h
a
r
g
e
,
de
s
i
n
a
t
e
d
b
y
d
e
s
i
g
n
,
t
o
c
o
m
p
l
y
w
i
t
h
t
h
e
en
g
i
n
e
e
r
i
n
g
r
e
q
u
i
r
e
m
e
n
t
s
o
f
t
h
e
In
t
e
r
n
a
t
i
o
n
a
l
R
e
s
i
d
e
n
t
i
a
l
B
u
i
l
d
i
n
g
C
o
d
e
,
20
1
8
L
a
t
e
s
t
E
d
i
t
i
o
n
@
1
3
0
/
1
6
0
-
m
p
h
3
se
c
g
u
s
t
w
i
n
d
l
o
a
d
r
a
t
i
n
g
.
La
r
r
y
M
.
O
l
i
v
e
r
E
n
t
e
r
p
r
i
s
e
s
I
n
c
.
72
2
8
O
a
k
b
r
i
a
r
D
r
i
v
e
S
o
u
t
h
Mo
b
i
l
e
,
A
L
.
3
6
6
1
9
PE
R
M
I
T
J
U
R
I
S
D
I
C
T
I
O
N
:
CI
T
Y
O
F
F
A
I
R
H
O
P
E
B.
F
.
E
.
:
1
2
'
'
A
.
C
L
.
R
W
FL
O
O
D
Z
O
N
E
:
"
X
"
CO
N
T
R
A
C
T
O
R
:
S
T
E
V
E
J
O
N
E
S
C
O
N
T
R
A
C
T
O
R
PR
OJ
E
C
T
:
R
E
M
O
D
E
L
S
I
N
G
L
E
F
A
M
I
L
Y
R
E
S
.
CL
I
E
N
T
:
L
U
C
I
N
D
A
&
C
H
I
P
C
H
A
P
P
E
L
L
E
LO
C
A
T
I
O
N
:
F
A
I
R
H
O
P
E
,
A
L
.
PH
Y
S
I
C
A
L
A
D
D
R
E
S
S
:
2
1
0
G
A
Y
F
E
R
C
T
.
Base Slab Elev: 24''' A.F.G. (Varies)
FINAL REVIEW - 12/04/25
PRELIM. REVIEW -09/16/25
PRELIM. REVIEW - 11/04/25
PRELIM. REVIEW - 10/07/25
PRELIM. REVIEW -09/17/25
c
2
0
2
5
C
O
P
Y
R
I
G
H
T
B
Y
K
.
A
.
T
.
D
e
s
i
g
n
s
I
n
c
.
T
h
e
s
e
d
r
a
w
i
n
g
s
a
r
e
N
O
T
T
O
B
E
re
p
r
o
d
u
c
e
d
o
r
c
o
p
i
e
d
i
n
a
n
y
f
o
r
m
w
h
a
t
s
o
e
v
e
r
w
i
t
h
o
u
t
t
h
e
w
r
i
t
t
e
n
pe
r
m
i
s
s
i
o
n
o
f
K
.
A
.
T
.
D
e
s
i
g
n
s
I
n
c
.
-
A
N
Y
D
U
P
L
I
C
A
T
I
O
N
I
S
P
R
O
H
I
B
I
T
E
D
A
N
D
PU
N
I
S
H
A
B
L
E
U
N
D
E
R
F
E
D
E
R
A
L
L
A
W
.
T
h
e
p
u
r
c
h
a
s
e
r
h
a
s
t
h
e
r
i
g
h
t
t
o
O
N
E
US
E
f
o
r
p
e
r
m
i
t
t
i
n
g
p
u
r
p
o
s
e
s
,
a
n
y
f
u
t
u
r
e
u
s
e
o
f
t
h
e
p
l
a
n
,
i
d
e
a
s
,
e
l
e
v
a
t
i
o
n
s
,
co
n
t
e
n
t
s
,
o
r
c
h
a
n
g
e
s
t
o
d
e
s
i
g
n
a
r
e
t
h
e
p
r
o
p
e
r
t
y
o
f
K
.
A
.
T
.
D
e
s
i
g
n
s
I
n
c
.
AN
D
M
U
S
T
B
E
A
U
T
H
O
R
I
Z
E
D
B
Y
K
.
A
.
T
.
D
e
s
i
g
n
s
I
n
c
.
A
N
Y
U
N
A
T
H
O
R
I
Z
E
D
U
S
E
WI
L
L
B
E
P
U
N
I
S
H
A
B
L
E
U
N
D
E
R
F
E
D
E
R
A
L
C
O
P
Y
R
I
G
H
T
L
A
W
S
.
EN
G
I
N
E
E
R
I
N
G
N
O
T
E
S
A 1.15A 1.15A 1.15A 1.15
Page 34 of 63
Page 35 of 63
: Michelle Melton-Null
Page 36 of 63
BOA 26.04 – Murphy Oil USA, 18186 Wright Blvd
April 21, 2026
Page 1 of 5
SUMMARY OF REQUEST
Public hearing to consider the request of Murphy Oil USA, Inc., on behalf of the Owner, RW Battles, LLC, for a
Special Exception to allow construction of an automobile service station on property zoned B-2, General
Business District. The property is located at 18186 Wright Blvd and is 1.13± acres.
SITE HISTORY
On February 1, 2021, SD 21.09, a 16-unit MOP was approved for this entire site (Shoppes at Point Clear) by the
Fairhope Planning Commission. At the time, the site was unzoned within the county and located within the
Fairhope Planning Jurisdiction. Thus, LND21-000064 was issued on May 25, 2021, for the entire site.
At its August 1, 2022, meeting the Fairhope Planning Commission unanimously approved ZC 22.09, for
Conditional Annexation to B-2, General Business District. Subsequently, Resolution No. 4614-22 “Project
Development Agreement between City and RW Battles, LLC” was accepted by the City Council on November
14, 2022, and Ordinance No. 1765 was signed on December 12, 2022, annexing the greater site into city limits.
On May 1, 2023, the final MOP was approved by the Planning Commission (SD 23.15).
A mandatory Site Plan Review is required for the proposed development due to the amount of impervious
surfacing being proposed and will follow this application.
STAFF COMMENTS
Automobile Service Stations within B-2 zoned districts are “permitted only on appeal and subject to special
conditions” in the Zoning Ordinance, hence this application.
Article III.A. of the Zoning Ordinance defines B-2 districts as follows:
B-2, General Business District: This district is intended to provide opportunity for activities causing noise and
heavy traffic, not considered compatible in the more restrictive business district. These uses also serve a
regional as well as a local market and require location in proximity to major transportation routes. Recreational
vehicle parks, very light production and processing activities are included.
Article II, Section A(4)(d)(2) describes the duty and power of the BOA that is applicable to this case.
“Special Exceptions - To hear and decide special exceptions to the terms of this ordinance upon which the
board is required to pass under this ordinance.”
Although the criteria detailed in Article II Section C.3.e(2) of the Zoning Ordinance controls the review of this
request for Special Exception, a conceptual site plan was submitted to staff along with the application, and
as such, staff has prepared the following general comments regarding the proposed site plan. It should be
noted, however, that a complete review of the proposed site plan will be included as part of the mandatory
Site Plan Review submitted to Planning Commission and City Council.
Full compliance with the Tree and Landscape Ordinance shall be required for this development. The applicant
has identified two (2) large heritage oak trees they intend to preserve. A complete Tree and Landscape Plan
and Tree Preservation Plan will need to be approved by the City Horticulturist as part of the Site Plan Review
process.
Page 37 of 63
BOA 26.04 – Murphy Oil USA, 18186 Wright Blvd
April 21, 2026
Page 2 of 5
There are 11 parking spaces proposed for the 2,824± SF building with 16 spaces under the fuel canopy
provided by the eight (8) fuel pumps. The number of parking spaces is compliant with the Zoning Ordinance;
however, at least one (1) space is required to utilize a pervious surface.
The site plan illustrates a compliant turning radius for fuel trucks.
The site plan did not provide the proposed building height nor the height of the canopy over the fueling stations.
The Final Plat (Instrument No. 2133748) has 35’ as the maximum building height on the Development Site Data
Table. The setbacks match those on the recorded Final Plat.
All signage shall conform to the Sign Ordinance and any other applicable rules and regulations. Currently,
there is an 8ft monument sign proposed in conformance with the Sign Ordinance. Cumulative branding
contributes to maximum amount of signage allowed on the site.
Applicant has a 10ft sidewalk easement in place on the eastern property line facing U.S. Hwy 98 (Greeno Rd).
Citizen Comments
During the public comment period staff did not receive any citizen comments.
Page 38 of 63
BOA 26.04 – Murphy Oil USA, 18186 Wright Blvd
April 21, 2026
Page 3 of 5
VARIANCE CONSIDERATIONS
Standards of Review:
Article II Section C.3.e(2) of the City of Fairhope Zoning Ordinance states that any other application (i.e.
Administrative Appeal or Special Exception) shall be reviewed by the Board of Adjustments under the following
criteria:
1) Compliance with the Comprehensive Plan;
2) Compliance with any other approved planning document;
3) Compliance with the standards, goals, and intent of this ordinance;
4) The character of the surrounding property, including any pending development activity;
5) Adequacy of public infrastructure to support the proposed development;
6) Impacts on natural resources, including existing conditions and ongoing post-development
conditions;
7) Compliance with other laws and regulations of the City;
8) Compliance with other applicable laws and regulations of other jurisdictions;
9) Impacts on adjacent property including noise, traffic, visible intrusions, potential physical impacts,
and property values; and
10) Impacts on the surrounding neighborhood including noise, traffic, visible intrusions, potential physical
impacts, and property values.
11) Overall benefit to the community;
12) Compliance with sound planning principles;
13) Compliance with the terms and conditions of any zoning approval; and
14) Any other matter relating to the health, safety, and welfare of the community.
Recommendation:
Based on the preceding, Staff recommends Approval of BOA 26.04 Murphy Oil USA, 18186 Wright Blvd Special
Exception to allow an automobile service station in a B-2, General Business District.
Page 39 of 63
EXHIBITS BOA 26.04 – Murphy Oil USA, 18186 Wright Blvd
April 21, 2026
Page 4 of 5
Excerpt from Table 3-2: Dimension Table – Lots and Principle Structure
Dimension
District or
Use Per Acre (UPA)
Setback Setback Setback Setback
All Structures
Height
B-1 None/ -none 20’ d 20’none e 30’ l
B-2 None/ - none 20’ d none f none e 30’ l
B-3a 7,500 s.f./ - 60’ 30’ 35’ 10’ 30% 30’ l
B-3b 7,500 s.f./ - 60’ 20’ 20’ none e none 30’ l
B-4 None/ - none 20’ 20’ 10’ 30’ l
Conceptual Site Plan
Page 40 of 63
EXHIBITS BOA 26.04 – Murphy Oil USA, 18186 Wright Blvd
April 21, 2026
Page 5 of 5
Excerpt from Table 3-1 Use Table
Zoning Districts B-1 B-2 Zoning Districts B-1 B-2
B-1 B-2
Dwelling Service
● ● ○ ○
● ● ○ ○
э э ○
○ ○
● ●
○
● ● ●
э э ● ●
● ○
Civic ○
● ●
● ● ○
● ●
● ● э
○ ●
○ ○ ●
○ ○ ●
● ●
● ● ○
○ ○
○ ○
Office Manufacturing
● ● ○
● ●
э э
Retail
● ● Rural
э э
● ●
●
○ ○
○
○
○
● = Allowed By Э = Special Conditions ○ = On Appeal
Page 41 of 63
(706)326-2053
2520 Wynnton Rd.
Columbus Georgia 31906
Page 42 of 63
Page 43 of 63
RAM ENGINEERING, LLC
PO Box 11696
ALEXANDRIA, LOUISIANA 71315
(318) 206-3838
Page 1 of 1
March 09, 2026
To: Hunter Simmons, Director of Planning
City of Fairhope
PO Box 429
Fairhope, AL 36533
Re: Murphy USA # 25211
18186 Wright Blvd
Fairhope, Alabama
RAM Project No. 2025.064
BOA Application
Dear Mr. Simmons,
On behalf of Murphy Oil USA, Inc., we are submitting a Board of Adjustments & Appeals (BOA)
application for the above-mentioned project. We request that this item be placed on the April 20,
2026 BOA agenda for consideration.
This request is being made to allow for the use of an automobile service station in the current B -2
zoning as required by Table 3-1, Article III of the City of Fairhope Zoning Ordinance.
The proposed use of the site is a 2,800 square foot convenience store with eight fuel islands under
canopy. This use meets the definition of a “automobile service station”, and as such requires BOA
approval.
Enclosed herewith are the following:
• Board of Adjustments & Appeals application
• Property owner authorization letter
• Site topographic and boundary survey
• Conceptual site plan
• Map of adjacent properties with zoning
• Names and addresses of property owners within 300 ft
Please let us know if you have any questions or require further information.
Sincerely,
Wesley D. Miller, PE, PLS
RAM Engineering, LLC
Enclosures: As listed herein
Cc: N/A
Page 44 of 63
COMPACT
PARKING
COMPACT
PARKING
±2
2
0
'
±227'
±1
6
5
'
±85
'
±174'
2,824 SF
8 MPD
M2 v1.0
NO
PARKING
COMPACT
PARKING
COMPACT
PARKING
ST
O
P
ST
O
P
STOP
20
0
P
E
A
C
H
S
T
R
E
E
T
MU
R
P
H
Y
O
I
L
U
S
A
,
I
N
C
.
EL
D
O
R
A
D
O
,
A
R
7
1
7
3
0
MU
R
P
H
Y
US
A
SH
E
E
T
N
O
.
MU
R
P
H
Y
U
S
A
(
N
T
I
)
18
1
8
6
W
R
I
G
H
T
B
L
V
D
.
FA
I
R
H
O
P
E
AL
A
B
A
M
A
CS
P
8 MPD (STACK)
VICINITY MAP
PARCEL DATA
S.F.ACRES
MURPHY PARCEL ± 49,508 ± 1.14
GREENSPACE PROVIDED 39%
REQUIRED PARKING
11 SPACES ( 4 SP. FOR 1st 400 S.F.
THEN 1 SP. / 400 AFTER)
30%-40% MUST BE COMPACT CAR STALLS (8'W)
PARKING SPACES PROVIDED 11 (+ 16 UNDER CANOPY)
ZONING B-2 (GENERAL BUSINESS DISTRICT)
SETBACKS *PER ALTA SURVEY PROVIDED BY CLIENT
FRONT (US HWY 98):*25'
SIDES:*20'
REAR (WRIGHT BLVD.):*25'
SIGNAGE 8' HEIGHT MAX
1 2 S.F./L.F. BUILDING FACE
DRIVEWAY SLOPE 2%+- (EXISTING/PROPOSED)
CO
N
C
E
P
T
U
A
L
S
I
T
E
P
L
A
N
CO
N
T
A
C
T
:
W
E
S
L
E
Y
M
I
L
L
E
R
RA
M
E
N
G
I
N
E
E
R
I
N
G
,
L
L
C
P.
O
.
B
O
X
1
1
6
9
6
AL
E
X
A
N
D
R
I
A
,
L
A
7
1
3
1
5
(3
1
8
)
2
0
6
-
3
8
3
8
PR
E
L
I
M
I
N
A
R
Y
D
O
C
U
M
E
N
T
RA
M
E
N
G
I
N
E
E
R
I
N
G
,
L
L
C
(
E
C
A
5
1
0
8
2
)
WE
S
L
E
Y
M
I
L
L
E
R
,
P
E
(
P
E
3
7
4
1
7
-
E
)
PARCEL AREA
SITE
LOCATION
RETA
I
L
SHOP
P
I
N
G
CENT
E
R
LOT "B"
U.
S
.
H
I
G
H
W
A
Y
9
8
WR
I
G
H
T
B
L
V
D
PUBL
I
X
PARK
I
N
G
PAVEMENT QUANTITIES
S.F.
PARKING ± 23,018
DRIVEWAYS (INSIDE R/W)±257
SIDEWALKS ± 1,666
DUMPSTER PAD ± 720
TANK PAD ± 1,551
Page 45 of 63
Professional Land Surveyors
Wattier Surveying, Inc.
Page 46 of 63
COMPACTPARKING COMPACTPARKING
±2
2
0
'
±227'
±1
6
5
'
±85
'
±174'
2,824 SF
8 MPD
M2 v1.0
NOPARKING
COMPACTPARKING COMPACTPARKING
ST
O
P
ST
O
P
STOP
20
0
P
E
A
C
H
S
T
R
E
E
T
MU
R
P
H
Y
O
I
L
U
S
A
,
I
N
C
.
EL
D
O
R
A
D
O
,
A
R
7
1
7
3
0
MU
R
P
H
Y
US
A
SH
E
E
T
N
O
.
MU
R
P
H
Y
U
S
A
(
N
T
I
)
FA
I
R
H
O
P
E
AL
A
B
A
M
A
ZO
N
I
N
G
M
A
P
CO
N
T
A
C
T
:
W
E
S
L
E
Y
M
I
L
L
E
R
RA
M
E
N
G
I
N
E
E
R
I
N
G
,
L
L
C
P.
O
.
B
O
X
1
1
6
9
6
AL
E
X
A
N
D
R
I
A
,
L
A
7
1
3
1
5
(3
1
8
)
2
0
6
-
3
8
3
8
PR
E
L
I
M
I
N
A
R
Y
D
O
C
U
M
E
N
T
RA
M
E
N
G
I
N
E
E
R
I
N
G
,
L
L
C
(
E
C
A
5
1
0
8
2
)
WE
S
L
E
Y
M
I
L
L
E
R
,
P
E
(
P
E
3
7
4
1
7
-
E
)
VICINITY MAP
SITE
LOCATION
18
1
8
6
W
R
I
G
H
T
B
L
V
D
.
WR
I
G
H
T
B
L
V
D
U.
S
.
H
I
G
H
W
A
Y
9
8
BATTLES RD.
SOUTHLAND PL.
MURPHY SITE
PARCEL ID #391372
B-2 GENERAL
BUSINESS DISTRICT
PARCEL ID #391373
B-2 GENERAL
BUSINESS DISTRICT
PARCEL ID #391375
B-2 GENERAL
BUSINESS DISTRICT
PARCEL ID #391379
B-2 GENERAL
BUSINESS DISTRICT
PARCEL ID #39376
B-2 GENERAL
BUSINESS DISTRICT
PARCEL ID #31364
BCZ - BASE COMMUNITY
ZONING DISTRICT
PARCEL ID #93607
BCZ - BASE COMMUNITY
ZONING DISTRICT
PARCEL ID #17515
B-2 GENERAL
BUSINESS DISTRICT
Page 47 of 63
Page 48 of 63
Page 49 of 63
: Michelle Melton-Null
Page 50 of 63
BOA 26.05 – Murphy Oil USA, Planter’s Pointe
April 21, 2026
Page 1 of 5
SUMMARY OF REQUEST
Public hearing to consider the request of Murphy Oil USA, Inc., on behalf of the Owner, Corte Cave/Mitchell
1, LLC, for a Special Exception to allow construction of an automobile service station on property zoned B-2,
General Business District. The property is located at the northwest corner of the intersection of State Hwy 181
and 104 and is 1.18± acres.
SITE HISTORY
The larger Planter’s Pointe development property received preliminary Multiple Occupancy Project (MOP)
approval in November 2020 (SD 20.34) whilst in Baldwin County and within Fairhope’s Planning Jurisdiction.
Preliminary Plat approval of the 9-lot subdivision (Re-subdivision of Lot 2) was granted November 2021 (SD
21.48).
The property conditionally annexed into the City in December 22, 2021, via Ordinance 1737.
A 12-month extension was granted at the October 2, 2023, Planning Commission meeting. Final Plat approval
of the 9-unit MOP was granted on December 4, 2023 (SD 23.32).
A mandatory Site Plan Review will follow the current BOA case.
STAFF COMMENTS
Automobile Service Stations within B-2 zoned districts are “permitted only on appeal and subject to special
conditions” in the Zoning Ordinance, hence this application.
Article III.A. of the Zoning Ordinance defines B-2 districts as follows:
B-2, General Business District: This district is intended to provide opportunity for activities causing noise and
heavy traffic, not considered compatible in the more restrictive business district. These uses also serve a
regional as well as a local market and require location in proximity to major transportation routes. Recreational
vehicle parks, very light production and processing activities are included.
Article II, Section A(4)(d)(2) describes the duty and power of the BOA that is applicable to this case.
“Special Exceptions - To hear and decide special exceptions to the terms of this ordinance upon which the
board is required to pass under this ordinance.”
Although the criteria detailed in Article II Section C.3.e(2) of the Zoning Ordinance controls the review of this
request for Special Exception, a conceptual site plan was submitted to staff along with the application, and
as such, staff has prepared the following general comments regarding the proposed site plan. A complete
review of the proposed site plan will be included as part of the mandatory Site Plan Review submitted to
Planning Commission and City Council.
There are 11 parking spaces proposed for the 2,824± SF building with 16 spaces under the fuel canopy
provided by the eight (8) fuel pumps. The number of parking spaces is compliant with the Zoning Ordinance;
however, at least one (1) space is required to utilize a pervious surface.
The site plan illustrates a compliant turning radius for fuel trucks.
Page 51 of 63
BOA 26.05 – Murphy Oil USA, Planter’s Pointe
April 21, 2026
Page 2 of 5
The site plan did not provide the proposed building height nor the height of the canopy over the fueling stations.
The Final Plat (Instrument No. 2132202) does not state a specific height for a building on Lot 4; however, B-2
districts require a maximum height of 30 feet. The setbacks match those on the recorded Final Plat.
All signage shall conform to the Sign Ordinance and any other applicable rules and regulations. Currently,
there is an 8ft monument sign proposed in conformance with the Sign Ordinance. Cumulative branding
contributes to maximum amount of signage allowed on the site.
Applicant has a 15ft sidewalk easement in place on the eastern property line facing AL Hwy 181 that meets an
existing sidewalk along AL Hwy 104.
Staff has concerns regarding the location of the proposed dumpster and its screening, given its proximity to a
primary entrance to the development. Although the Zoning Ordinance does not mandate alternative
placement for the dumpster within the lot, staff recommends that the applicant consider other interior
locations prior to submitting an application for Site Plan Review.
Similarly, staff has reservations about the quantity and separation of outdoor servicing activities—such as ice
pads, ATMs, and propane pads—as well as their positioning away from the proposed building. It is also
important to note that Article IV.B.2.a of the Zoning Ordinance stipulates that these activities must be
screened from public view. The current plans do not reflect this requirement, and appropriate revisions will
need to be made before proceeding with Site Plan Review.
Citizen Comments
During the public comment period staff did not receive any citizen comments.
Page 52 of 63
BOA 26.05 – Murphy Oil USA, Planter’s Pointe
April 21, 2026
Page 3 of 5
VARIANCE CONSIDERATIONS
Standards of Review:
Article II Section C.3.e(2) of the City of Fairhope Zoning Ordinance states that any other application (i.e.
Administrative Appeal or Special Exception) shall be reviewed by the Board of Adjustments under the following
criteria:
1) Compliance with the Comprehensive Plan;
2) Compliance with any other approved planning document;
3) Compliance with the standards, goals, and intent of this ordinance;
4) The character of the surrounding property, including any pending development activity;
5) Adequacy of public infrastructure to support the proposed development;
6) Impacts on natural resources, including existing conditions and ongoing post-development
conditions;
7) Compliance with other laws and regulations of the City;
8) Compliance with other applicable laws and regulations of other jurisdictions;
9) Impacts on adjacent property including noise, traffic, visible intrusions, potential physical impacts,
and property values; and
10) Impacts on the surrounding neighborhood including noise, traffic, visible intrusions, potential physical
impacts, and property values.
11) Overall benefit to the community;
12) Compliance with sound planning principles;
13) Compliance with the terms and conditions of any zoning approval; and
14) Any other matter relating to the health, safety, and welfare of the community.
Recommendation:
Based on the preceding, Staff recommends Approval of BOA 26.05 Murphy Oil USA, Planter’s Pointe Special
Exception to allow an automobile service station in a B-2, General Business District.
Page 53 of 63
EXHIBITS BOA 26.05 – Murphy Oil USA, Planter’s Pointe
April 21, 2026
Page 4 of 5
Excerpt from Table 3-2: Dimension Table – Lots and Principle Structure
Dimension
District or
Use Per Acre (UPA)
Setback Setback Setback Setback
All Structures
Height
B-1 None/ -none 20’ d 20’none e 30’ l
B-2 None/ - none 20’ d none f none e 30’ l
B-3a 7,500 s.f./ - 60’ 30’ 35’ 10’ 30% 30’ l
B-3b 7,500 s.f./ - 60’ 20’ 20’ none e none 30’ l
B-4 None/ - none 20’ 20’ 10’ 30’ l
Conceptual Site Plan
Page 54 of 63
EXHIBITS BOA 26.05 – Murphy Oil USA, Planter’s Pointe
April 21, 2026
Page 5 of 5
Excerpt from Table 3-1 Use Table
Zoning Districts B-1 B-2 Zoning Districts B-1 B-2
B-1 B-2
Dwelling Service
● ● ○ ○
● ● ○ ○
э э ○
○ ○
● ●
○
● ● ●
э э ● ●
● ○
Civic ○
● ●
● ● ○
● ●
● ● э
○ ●
○ ○ ●
○ ○ ●
● ●
● ● ○
○ ○
○ ○
Office Manufacturing
● ● ○
● ●
э э
Retail
● ● Rural
э э
● ●
●
○ ○
○
○
○
● = Allowed By Э = Special Conditions ○ = On Appeal
Page 55 of 63
Page 4 of6
APPLICATION FOR BOARD OF ADJUSTMENTS
Application Type: [] Administrative Appeal El Special Exception D Variance
Property Owner / Leaseholder Information
Name: CORTE, CAVE/MITCHELL 1, L L c Phone Number: 251-421-2641
Street Address: P.O. B ox 81322
City: Mobile________ State: AL___Zip: 36680
Applicant / Agent Information
If different from above.
Notarized letter from property owner is required if an agent is used for representation. Name: Muq,h, Oil USA, Inc.Phone Number: (318) 206-3838
Street Address: :>nn p -:-, , . ,,., �_.,.__......,_.....__��-'----- ---------------- ----
City: EL Dor,.1 State: Arkansas Zip: ..._7_.1..._7-'-'� ... 1 _______ _
Site Plan with Existing Conditions Attached:
Site Plan with Proposed Conditions Attached:
Variance Request Information Complete:
Names and Address of all Real Property Owners within 300 Feet of Above Described Property Attached:
Applications for Administrative Appeal or Special Exception:
Please attach as a separate sheet(s) information regarding the administrative decision made or information regarding the use seeking approval. Please feel free to be as specific or as general as you wish in your description. This information will be provided to the Board before the actual meeting date. It is to your benefit to explain as much as possible your position or proposal.
I certify that I am the property owner /leaseholder of the above described property and hereby submit this application to the City for review. *If property is owned 9y Fairhope Single Tax Cm-p. an authorized Single Tax representative shall si
� t�re a� /112,1Clf�,II UC-
Property Owner/Leaseholder Printed Name Signature
Date v�1��'l-? Fairhope Single Tax Corp. (If Applicable)
Page 56 of 63
Authorization Letter
To Whom it May Concern:
I, CORTE. CAVE/MITCHELL 1. LLC, hereby authorize
Owner of Record
Chase de la Houssaye & Derek Brown of Murphy Oil USA. Inc.
Authorized Agent
-and-
Wesley Miller of RAM Engineering, LLC
Authorized Agent Company
Company
to represent me and to act on my behalf in regard to the application for
Murphy USA.
Name of Development/ Application
Owner of Record Name (Print)
Page 57 of 63
RAM ENGINEERING, LLC
PO Box 11696
ALEXANDRIA, LOUISIANA 71315
(318) 206-3838
Page 1 of 1
March 09, 2026
To: Hunter Simmons, Director of Planning
City of Fairhope
PO Box 429
Fairhope, AL 36533
Re: Murphy USA # 24218
Hwy 181 & Hwy 104
Fairhope, Alabama
RAM Project No. 2025.002
BOA Application
Dear Mr. Simmons,
On behalf of Murphy Oil USA, Inc., we are submitting a Board of Adjustments & Appeals (BOA)
application for the above-mentioned project. We request that this item be placed on the April 20,
2026 BOA agenda for consideration.
This request is being made to allow for the use of an automobile service station in the current B -2
zoning as required by Table 3-1, Article III of the City of Fairhope Zoning Ordinance.
The proposed use of the site is a 2,800 square foot convenience store with eight fuel islands under
canopy. This use meets the definition of a “automobile service station”, and as such requires BOA
approval.
Enclosed herewith are the following:
• Board of Adjustments & Appeals application
• Property owner authorization letter
• Site topographic and boundary survey
• Conceptual site plan
• Map of adjacent properties with zoning
• Names and addresses of property owners within 300 ft
Please let us know if you have any questions or require further information.
Sincerely,
Wesley D. Miller, PE, PLS
RAM Engineering, LLC
Enclosures: As listed herein
Cc: N/A
Page 58 of 63
±194'
±256'
±1
7
9
'
±1
6
9
'
±35
'
±52
'
ST
O
P
2,
8
2
4
S
F
8
M
P
D
v4
.
0
NO
PA
R
K
I
N
G
CO
M
P
A
C
T
PA
R
K
I
N
G
CO
M
P
A
C
T
PA
R
K
I
N
G
CO
M
P
A
C
T
PA
R
K
I
N
G
CO
M
P
A
C
T
PA
R
K
I
N
G
20
0
P
E
A
C
H
S
T
R
E
E
T
MU
R
P
H
Y
O
I
L
U
S
A
,
I
N
C
.
EL
D
O
R
A
D
O
,
A
R
7
1
7
3
0
MU
R
P
H
Y
US
A
SH
E
E
T
N
O
.
MU
R
P
H
Y
U
S
A
(
N
T
I
)
HW
Y
1
8
1
/
H
W
Y
1
0
4
FA
I
R
H
O
P
E
AL
A
B
A
M
A
CS
P
8 MPD (STACK)
VICINITY MAP
PARCEL DATA
S.F.ACRES
MURPHY PARCEL ± 51,267 ± 1.18
GREENSPACE PROVIDED 38%
REQUIRED PARKING
11 SPACES ( 4 SP. FOR 1st 400 S.F.
THEN 1 SP. / 400 AFTER)
30%-40% MUST BE COMPACT CAR STALLS (8'W)
PARKING SPACES PROVIDED 11 (+ 16 UNDER CANOPY)
ZONING B-2 (GENERAL BUSINESS DISTRICT)
SETBACKS
*PER PLANTERS POINT SUBDIVISION, RE-SUB
LOT 2, NW CORNER HWY 181-HWY104
SUBDIVISION
FRONT (ROAD FRONTAGE):*50'
SIDES:*60' (SOUTH) *10' (NORTH)
REAR:*10'
SIGNAGE 8' HEIGHT MAX
1 2 S.F./L.F. BUILDING FACE
DRIVEWAY SLOPE 2%+- (EXISTING/PROPOSED)
CO
N
C
E
P
T
U
A
L
S
I
T
E
P
L
A
N
CO
N
T
A
C
T
:
W
E
S
L
E
Y
M
I
L
L
E
R
RA
M
E
N
G
I
N
E
E
R
I
N
G
,
L
L
C
P.
O
.
B
O
X
1
1
6
9
6
AL
E
X
A
N
D
R
I
A
,
L
A
7
1
3
1
5
(3
1
8
)
2
0
6
-
3
8
3
8
PR
E
L
I
M
I
N
A
R
Y
D
O
C
U
M
E
N
T
RA
M
E
N
G
I
N
E
E
R
I
N
G
,
L
L
C
(
E
C
A
5
1
0
8
2
)
WE
S
L
E
Y
M
I
L
L
E
R
,
P
E
(
P
E
3
7
4
1
7
-
E
)
PARCEL AREA
FUTURE
RETAIL
SITE
LOCATION
FUTURE
RETAIL
PUBLIX
ST
A
T
E
H
I
G
H
W
A
Y
1
8
1
STATE HIGHWAY 104
SIGNALIZED
INTERSECTION
PAVEMENT QUANTITIES
S.F.
PARKING ± 25,100
DRIVEWAYS (INSIDE R/W)± 0
SIDEWALKS ± 1,675
DUMPSTER PAD ± 720
TANK PAD ± 1,376
Page 59 of 63
ww
w
.
g
r
e
e
n
b
e
r
g
f
a
r
r
o
w
.
c
o
m
Ph
o
n
e
:
(
7
7
0
)
4
2
2
-
8
1
8
1
At
l
a
n
t
a
,
G
A
3
0
3
0
9
Fa
x
:
(
7
7
0
)
4
2
2
-
8
1
0
1
12
3
0
P
e
a
c
h
t
r
e
e
S
t
.
N
W
,
S
u
i
t
e
2
9
0
0
Page 60 of 63
±194'
±256'
±1
7
9
'
±1
6
9
'
±35
'
±52
'
ST
O
P
2,8
2
4
S
F
8 M
P
D
v4.
0
NO
PAR
K
I
N
G
COM
P
A
C
T
PAR
K
I
N
G
COM
P
A
C
T
PARK
I
N
G
COM
P
A
C
T
PAR
K
I
N
G
COM
P
A
C
T
PAR
K
I
N
G
20
0
P
E
A
C
H
S
T
R
E
E
T
MU
R
P
H
Y
O
I
L
U
S
A
,
I
N
C
.
EL
D
O
R
A
D
O
,
A
R
7
1
7
3
0
MU
R
P
H
Y
US
A
SH
E
E
T
N
O
.
MU
R
P
H
Y
U
S
A
(
N
T
I
)
HW
Y
1
8
1
/
H
W
Y
1
0
4
FA
I
R
H
O
P
E
AL
A
B
A
M
A
VICINITY MAP
ZO
N
I
N
G
M
A
P
CO
N
T
A
C
T
:
W
E
S
L
E
Y
M
I
L
L
E
R
RA
M
E
N
G
I
N
E
E
R
I
N
G
,
L
L
C
P.
O
.
B
O
X
1
1
6
9
6
AL
E
X
A
N
D
R
I
A
,
L
A
7
1
3
1
5
(3
1
8
)
2
0
6
-
3
8
3
8
PR
E
L
I
M
I
N
A
R
Y
D
O
C
U
M
E
N
T
RA
M
E
N
G
I
N
E
E
R
I
N
G
,
L
L
C
(
E
C
A
5
1
0
8
2
)
WE
S
L
E
Y
M
I
L
L
E
R
,
P
E
(
P
E
3
7
4
1
7
-
E
)
SITE
LOCATION
ST
A
T
E
H
I
G
H
W
A
Y
1
8
1
STATE HIGHWAY 104
ST
A
T
E
H
I
G
H
W
A
Y
1
8
1
STATE HIGHWAY 104
PARCEL ID #77680
B3 GENERAL
BUSINESS
PARCEL ID #627491
B2 GENERAL
BUSINESS DISTRICT
PARCEL ID #626308
B2 GENERAL
BUSINESS DISTRICT
MURPHY SITE
PARCEL ID #626309
B2 GENERAL
BUSINESS DISTRICT
PARCEL ID #626311
B2 GENERAL
BUSINESS DISTRICT
PARCEL ID #19982
B2 GENERAL
BUSINESS DISTRICT
PARCEL ID #626310
B2 GENERAL
BUSINESS DISTRICT
PARCEL ID #388078
B2 GENERAL
BUSINESS DISTRICT
PARCEL ID #44627
RSF - E - RESIDENTIAL
SINGLE FAMILY ESTATE