HomeMy WebLinkAboutO-552ORDINANCE NO. 552 AN ORDINANCE TO ADOPT THE NATIONAL ELECTRIC CODE, 1975 REVISION AND REQUIREMENTS OVER AND ABOVE THE NATIONAL CODE DUE TO CONDITIONS NATIVE TO THIS AREA. BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY OF FAIRHOPE, ALABAMA that all electrical work and all materials and appliances used in connection therewith installed within the City are con- formed to the rules, regulations and requirements of the 1975 National Electric Code and said rules are hereby adopted by reference as fully as if set out at length therein. BE IT FURTHER ORDAINED that the following requirements over and above the National Electric Code are required due to conditions native to this area: 1. A minimum of 100 AMP meter and breaker installation shall be required for all trailers. 2. Any new home or upgraded service shall have a minimum entrance of 100 AMP with 12 branch circuits. Any new home with electric heat shall have a minimum of 200 AMP capacity with at least 24 branch circuits. All panels, except power panels and those used in con- junction with a power panel, must have a main dis- connect. 3. For permanent residences, nonmetalic sheathed cable No. 12 AWG Copper or larger is required. Switch legs controlling only one or two ceiling fixtures may be No. 14 AWG Copper. Aluminum or copper clad aluminum smaller than No. 6 will not be approved. THIS ORDINANCE SHALL BECOME LAW UPON ITS DUE ADOPTION AND PUBLICATION AS REQUIRED BY LAW. ADOPTED THIS THE 12th DAY OF MAY, 1975. Approved James P. Nix Mayor Attest: Marie Moore City Clerk I, Marie Moore, Clerk of the City of Fairhope, Alabama hereby certify that the foregoing is a true and correct copy of Ord- inance No. 552 as adopted by the Fairhope City Council at their meeting of May 12, 1975. j. Clerk of the City oy Fairhope, A a.